Loading...
HomeMy WebLinkAboutConditions of PermitCOND ITIONS OF P ERMIT BLRE-01-25-9060 COWHEY FAMILY TRUST New Single-family dwelling w/ attached garage & unfinished basement 227 Silver Mountain Dr, GWS lronbridge PUD, Lot 1 1B - 2395124181 1 B 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 201B I NTERNATIONAL EN ERGY CONSERVATION CODE ( I.E.C.C,) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY, 4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION. 6) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 3,000 PSF soil bearing. lnclude compaction report for any structural fill. 7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. 8) BLOWER DOOR TEST tS REOUtRED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 9) A LOT TMPROVEMENT CERT|FtCATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK REOUIREMENTS / BUILDING ENVELOPE. 10) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSIONAL LICENSED SURVEYOR, lS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS.BUILT ROOFS COMPLY WITH GARFIELD COUNTY'S 35-FOOT BUILDING HEIGHT LIMIT IN THE IRONBRIDGE PUD. 1 1) PLUMBING / BUILDING CONTRACTOR SEE C1 SITE PLAN GARAGE REFERENCE FOR SANITARY SEWER CONNECTION: INSTALL GRINDER EJECTION PUMP. FIELD VERIFY. 12) SIP MANUFACTURERS SHOP DRAWINGS MUST BE ON SITE AT FRAME INSPECTION. GENERAL CONTRACTOR AND MEP SUB CONTRACTORS ARE RECOMMENDED TO FULLY REVIEW SIP 600 FOR ALLOWABLE'CUTS'AND 'DRILLING' PURSUANT TO SIPS MANUFACTURER SPECIFICATIONS. SIPS PREMIER ICC - ES REPORT IS FURTHER ATTACHED TO FIELD SET - OWNER BUILDER AND CONTRACTORS TO ENSURE GARAGE / HOUSE FIRE SEPARATION IS COMPLETED PURSUANT TO SIP'S MANUFACTURER'S LISTED SPECI FICATIONS. 13) PRESCR|pTtVE PATH USTNG 2018 rECC TABLE R402.1.2 lS CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE M1507.3.3(1 )AND (2)SHOWN ON COVER SHEET. $ .{ la $\ N