Loading...
HomeMy WebLinkAboutER ReportColleen Wirth From: Sent: To: Subject: Attachments: Colleen Wirth Thursday, February 13,2025 B:30 AM Colleen Wirth FW: Premier SIPS SIPS Premier- ESR-4524.pdf; SIPS Premier Details.pdf From: Joh n Pla no <jplano@ga rfield-county.com> Sent: Thursday, February 13,2025 8:03 AM To: Colleen Wirth <cwirth@garfield-county.com>; Matt Provost <mprovost@garfield-county.com>; John Hendricks <jhe nd ricks@ga rfie ld-cou nty.com> Subject: Premier SIPS Fotks, Col.teen is reviewing a Premier SIP house. There are some specifics regarding the instal,l,ation The ER Report section 4.2.11.3.3 requires (2) tayers on each side for a one-hour assembl'y. My interpretation is that they need (2) [ayers for the garage separation. I incl,uded the detait book, so you guys can get famitiar or re-famitiarize yoursetf when doing inspections. Cotteen, maybe justffiapte the ER Report to the plans for reference. John Ptano Chief Buitd ing Officiat Garfietd Cou nty Buitding Department 108 8th Street #401 Gtenwood Springs, CO 81601 (970) 945-1 377 Ext. 1 560 $ \ s .\t \ 1 trillws*- ffi --rS. www.icc-es.ors | (800) 423-6587 | (562) 699-0543 A Subsidiary of the lnternational Code Councila ICG-ES Evaluation Report ESR-4524 DIVISION: 06 00 O0-WOOD, PLASTICS AND COMPOSITES Section: 06 12 O0-Structural Panels REPORT HOLDER: PREMIER BUILDING SYSTEMS, LLC EVALUATION SUBJECT: PREMIER STRUCTURAL INSULATED PANELS (SIPS) ADDITIONAL LISTEES BIG SKY INSULATION, INC. EXTREME PANEL TECHNOLOGIES 1.0 EVALUATION SCOPE Compliance with the following codes: | 2024,2021 and 2018 tnternational Building Code@ (lBC) | 2024, 2021 and 2018 tnternational Residential Code@ (rRc) For evaluation for compliance with codes adopted by the Los Angeles Department of Building and Safety (LADBS), see ESR-4524 Citv of LA Supplement. For evaluation for compliance with codes adopted by the State of California see ESR-4524 CA Supplement w/ Exterior Wildfire Exposure. Premier SIP use in Fire Hazard Severity Zone is addressed in ESR-4524 IWUIC Supplement. Properties evaluated: r Structural r Fire resistance r Thermal Barrier 2.0 usEs Premier Structural lnsulated Panels (Premier SlPs) are structural insulated roof, wall and floor panels capable of resisting transverse, axial and in-plane shear loads. The Premier SlPs are combustible materials when considering construction type in accordance with IBC Chapter 6. The SlPs may be used in fire-rated assemblies when installed in accordance with Section 4.2.11. Rer.ssued February 2023 Revised January 2025 This repoft is subject to renewal February 2025. 3.0 DESCRIPTION 3.1 General: Premier SlPs are factory-assembled, engineered-wood- faced, structural insulated panels (SlP) with an expanded polystyrene (EPS) foam core. Premier SlPs are intended for use as load-bearing or non-load bearing wall panels, roof panels, floor panels and headers. Premier SlPs are available in 41lz-inch (114 mm) through 1211q-inch (311 mm) thicknesses. Premier SlPs are custom made to the specifications for each use and are assembled under factory-controlled conditions. The maximum Premier SlPs size is 8 feet (2.44 m) wide and up to 24 feet (7.32 m) in length. 3.2 Materials: 3.2.1 Facing: The facing material is eithe//ro, 518,23132 or %-inch-thick, Exposure 1 oriented strand board (OSB) with a24116 span rating and complying with DOC PS2. The OSB facings are continuous for each SlP. 3.2.2 Expanded Polystyrene (EPS) Core: The EPS foam plastic core complies with ASTM C578, Type l. The EPS foam plastic has a flame spread rating not exceeding 25 and a smoke-developed rating not exceeding 450 when tested in accordance with ASTM E84. The EPS cores for SlPs up lo 1211+inch (3'l 1 mm) thickness, comply with IBC Section 2603.3 Exception 4. 3.2.3 Adhesive: Facing materials are adhered to the core material using a structural adhesive. The adhesive is applied during the lamination process in accordance with the in-plant quality system documentation. 3.2.4 Material Sources: The facing, core, adhesive, and accessories used in the construction of Premier SlPs shall be composed only of materials from approved sources as identified in the in-plant quality system documentation. 3.2.5 Splines: Premier SlPs are interconnected with Bor/Block splines, l-Beam splines (Type l) or Lumber splines (Type L). 3.2.5.1 Box/Block Splines: Box/Block splines (Figure 1) are manufactured in the same manner as the Premier SlPs exceptwith an overall thickness that is 1 inch (25.4 mm) less than the overall thickness of the panel to be joined. Box/Block splines are a minimum of 3 inches (76.2mm) wide. ICC-ES Evalwtion Reports are not lo be construed as tepresenling aesthetics or any other attributes not specifcally qddressed, nor qre they to bre :":;,#.":, Ns _SiF,-asanendorsementofihesubiectofthereportorarecommendationforitsuse.Thereisnov,arrantybylCCEvalualionSeruice, I'LC,expressorimptied,as liEI fEFltoanyfndingorothermatterinthisrepott,orastoanyproductcoveredbythereport. fii.'id3l! # Copyright @ 2025 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 19 ESR-4624 I Moat Widcly Acccptcd and Trusted Page 2 of 19 3.2.5.2|-Beam Spiine: I-Beam Splines (Figure 1) consist of pre-fabricated wood l-joists consisting of top and bottom chords held together by a structural web member. Only Premier approved l-Beam splines may be used with Premier SlPs. 3.2.5.3 Lumber Splines: Lumber splines consist of one or more plies of dimensional lumber. Equivalent engineered wood material may be used when jrrstified hy a registered desrgn protessional. 3.2.6 Accesrories 3.2.6.1 Premier SlPs Screws: Premier SIP Screws are used to fasten Premier SlPs to underlying structural supports and SIP to SIP intersections as shown in the manufacturer's details. The minimum shank diameter is 0.166 inch (4.7 mm) and a minimum head diameter of 0.620 inch (15.5 mm). Screws are available in lengths from 6 to 18 inches (152.4 to 457.2 mm) measured from the tip. The thread length for all screws is 2 % inches (70 mm) measured from the tip. 3.2.6.2 Premier SlPs Low VOC Sealant: Premier Slps Low VOC Sealant is specified as a sealant during installation of Premier SlPs. Premier SlPs Low VOC Sealant is applied to splines, plates and SIP to Slp intersections as shown in the manufacturer's details. 3.2.6.3 Premier SlPs Tape: Premier SlPs Tape is specified as a joint sealing tape during installation of Premier Slps. Premier SlPs Tape is applied to joints, termination boundaries and SIP to SIP spline connections as shown in the manufacturer's details. 4.0 DESIGN AND INSTALLATION 4.1 Design: 4.',.1 General: The scope of this report is limited to the evaluation of Premier SlPs. Panel connections and other details related to incorporation of the panel into the overall structural system of a building are outside the scope of this report. 4.1.2 Design Approval: Where required by the authority having jurisdiction, structures using Premier SlPs shall be designed by a registered design professional. Construction documents, including engineering calculations and drawings providing floor plans, window details, door details, and connector details, shall be submitted to the code official when application is made for a permit. The individual preparing such documents shall possess the necessary qualifications as required by the applicable code and the professional registration laws of the state where the construction is undertaken. Approved construction documents shall be available at all times on the jobsite during installation. 4.1.3 Design Loads: Design loads to be resisted by the Premier SlPs shall be as required under the applicable building code. Loads on the Premier SlPs shall not exceed the loads noted in this report. 4.1.4 Allowable Loads: Allowable axial, traneveroo, and in-plane shear loads shall be selected from Tables 1 through 10. Calculations demonstrating that the loads applied are less than the allowable loads described in this report shall be submitted to the code official for approval. For loading conditions not specifically addressed herein, structural members designed in accordance with accepted engineering practice shall be provided to meet applicable code requirements. 4.1.5 Concentrated Load: Axial loads shall be applied to the Premier SlPs through continuous members such as structural insulated roof or floor panels or repetitive members spaced at regular intervals of 24 inches (610 mnr) on center or less. Such members shall be fastened to a rim board, cap plate or similar member to distribute the load to the Premier SlPs. Where a rim board, cap plate or similar member is not provided, the reaction at the end of each member shall not exceed the concentrated loads provided in Tables 5 through 7. 4.1.5 Eccentric and Side Loads: Axial loads shall be applied concentrically to the top of the Premier SlPs. Loads shall not lre applied eccentrically or through framing attached to one side of the panel (such as balloon framing) except whcre additional engineering rlrrr:rrrrrerrtartir.rrr is provided. 4.1.7 Openings: Except as provided in Tables 8 and 9, openings in panels shall be reinforced with wood or steel designed in accordance with accepted engineering practice to resist all loads applied to the opening as required by the applicable code. Details for door and window openings shall be provided to clarify the manner of supporting axial, transverse and/or in-plane shear loads at openings. Such details shall be shown on approved design documents and subject to approval by the local authority having jurisdiction. 4.1.8 ln-Plane Shear Design: Shear walls utilizing boVblock or lumber splines shall be sized to resist all code required wind and seismic loads without exceeding the allowable loads provided in Table 10. Shear wall chords, hold-downs and connections to transfer shear forces between the wall and surrounding structure shall be designed in accordance with accepted engineering practice. The allowable loads provided in Table 10 as published, are limited to assemblies with height-to-width ratios not exceeding those published in Footnote 'l of Table 10. The allowable loads for shear walls with height: width ratios exceeding 2:1 using dimensional lumber splines must be adjusted in accordance with Footnote 5 of Table 10. 4.1.8.1 Seismic Design Gategories A, B and C: The shear wall configurations in Table 10 were monotonically tested to determine performance. These shearwalls are limited to structures in Seismic Design Categories A, B and C. 4.1.8.2 Seismic Design Categories A through F: The shear wall configurations in Table 11 were tested cyclically in shear with a combined vertical load. These sheanrvalls may be used in structures in Seismic Design Categories A through F. 4.'t.9 Horizontal Diaphragms: Horizontal diaphragms utilizing box/block splines shall be sized to resist all code required wind and seismic loads without exceeding the allowable loads provided in Table 12. Diaphragm chords and connections to transfer shear forces between the diaphragm and surrounding structure shall be designed in accordance with accepted engineering practice. The maximum diaphragm length-to-width ratio shall not exceed those specified in Table 12. 4.1.10Gombined Loads: When loading conditions result in the panels resisting combined stresses, the sum of the ratios of actual load over allowable load nrusl Lre less than 1.0. 4.1.11 SIP Protection: 4.1.11.1 Thermal Barrier at Wall, Roof and Floor: Premier SlPs must be separated from the interior of the building by an approved thermal barrier of lz-inch (12.7 mm) gypsum wallboard or equivalent thermal barrier complying with and installed in accordance with IBC Section 2603.4 or IRC Section R316.4 as applicable. When used as the thermal barrier, gypsum wallboard must be fastened to the face of the panels with minimum 11l+-inch-long (31.7 mm), No. 6, Type W drywall screws spaced in accordance with ASTM C840 for use under the EsR4524 | Most Widelv Accented and Trusted Paqe 3 of 19 IBC or Table R702.3.5 of the lRC, using 16-inch-on-center (406.4 mm) framing spacing guidelines. 4.1.1'l .2 Thermal Barrier at Floor Surface: An approved thermal barrier must be installed over the top surface of the floor panels, such as minimum 7/ro-inch-thick (76 mm) wood- based structural use sheathing installed in accordance with the applicable code. 4.2 lnstallation: 4.2.1 General: Premier SlPs shall be fabricated, identified and installed in accordance with this report, the approved construction documents and the applicable code. ln the event of a conflict between the manufacturer's published installation instructions and this report, this report shall govern. Approved construction documents shall be available at all times on the jobsite during installation. 4.2.2 Splines: Premier SlPs are interconnected at the panel edges through the use of a spline. The spline type may be of any configuration listed in Section 3.2.5 as required by the specific design. The spline shall be, secured in place with not less than 0.113-inch x 2.375-inch (2.9 mm x 63.5 mm) smooth shank nails, [0.275 inch (7 mm) head diameterl, 6 inches (152 mm) on center on both sides of the Premier SlPs or an approved equivalent fastener. All joints shall be sealed in accordance with the Premier SlPs manufacturer's installation instructions. Alternate spline connections may be required for Premier SlPs subjected to in-plane shear forces. Such Premier SlPs shall be interconnected exactly as required in Table 10, Table 1 I or Table 12 or as directed by the designer. 4.2.3 Plates: The top and bottom plates of the panels shall be dimensional lumber or engineered wood sized to match the core thickness ofthe panel. The plates shall be secured using not less than 0.113-inch x 2.375-inch (2.9 mm x 63.5 mm) nails, [0.275-inch (7 mm) head diameter], spaced 6 inches (152 mm) on center on both sides of the panel or an approved equivalent fastener. Alternate plate connections may be required for panels subjected to in-plane shear forces and shall be interconnected as required in Table 10, 11 or Table 12 or as directed by the designer. 4.2.4 Cutting and Notching: No field cutting or routing of the panels shall be permitted except as shown on approved drawings. 4.2.5 Protection from Decay: Premier SlPs that rest on exterior foundation walls shall not be located within 8 inches (203 mm) of exposed earth. Premier SlPs supported by concrete or masonry that is in direct contact with earth shall be protected from the concrete or masonry by a moisture barrier. 4.2.6 Protection from Termites: ln areas subject to damage from termites, Premier SlPs shall be protected from termites using an approved method. Premier SlPs shall not be installed below grade or in contact with earth. 4.2.7 Heat-producing Fixtures: Heat-producing fixtures shall not be installed in the Premier SlPs unless protected by a method approved by the code official or documented in test reports. This limitation shall not be interpreted to prohibit heat-producing elements with suitable protection. 4.2.8 Plumbing Installation Restrictions: Plumbing and waste lines may extend at right angles through the wall panels but are not permitted vertically within the core. Lines shall not interrupt splines or panel plates unless approved by a registered design professional. 4.2.9 Voids and Holes: 4.2.9.1 Voids in Gore: ln lieu of openings designed in accordance with Section 4.1.7, the following voids are permitted. Voids may be provided in the panel core during fabrication at predetermined locations only. Voids parallel to the panel span shall be limited to a single 11lz-inch (38.1 mm) maximum diameter hole. Such voids shall be spaced a minimum of 4 feet (1 .22 m) on center, measured perpendicular to the panel span. Two 1/z-inch-diameter (12.7 mm) holes may be substituted for the single 11lz-inch- diameter (38.'l mm) hole provided they are maintained parallel and within 2 inches (50.8 mm) of each other. Voids perpendicular to the panel span shall be limited to a single 11lz-inch-maximum-diameter (38.1 mm) hole placed not closer than 16 inches (406 mm) from the support. Additional voids in the same direction shall be spaced not less than 28 inches (711.2mm) on center. 4.2.9.2 Holes in Panels: Holes may be placed in Premier SlPs during fabrication at predetermined locations only. Except as noted herein, holes shall be limited to 4-inches x 4-inches (102 mm x 102 mm) square. The minimum distance between holes shall not be less than 4 feet (1 .22 m) on center measured perpendicular to the panel span and 24 inches (610 mm) on center measured parallel to the panel span. Not more than three holes shall be provided in a single line of holes parallel to the panel span. The holes may intersect voids permitted elsewhere in this report. \Men Premier SlPs with a 101/a-inch (260 mm) or 1211A-inch (311 mm) thickness are used horizontally, holes shall be limited to a maximum 8-inch (203 mm) diameter. The minimum distance between holes shall not be less than 4 feet (1.22 m) on center measured perpendicular to the panel span and 4 feet (1.22 m) on center measured parallel to the panel span. The minimum distance from the edge of any hole to the support of any Premier SlPs shall not be less lhan 24 inches (610 mm) and the minimum distance from the edge of any hole to any edge of an individual Premier SlPs shall not be less than 19 inches (483 mm). When more than three holes are present in a single line parallel to the panel span, the allowable loads in Tables 1 through 3 shall be reduced by 25 percent. 4.2.10 PanelGladding: 4.2.10.1 Roof Govering: The roof covering, underlayment and flashing shall comply with the applicable codes. All roofing materials must be installed in accordance with the manufacturer's installation instructions. The use of roof coverings requiring the application of heat during installation shall be reviewed and approved by a registered design professional. 4.2.10.2 Exterior Wall Covering: Panels shall be covered on the exterior by a water-resistive barrier as required by the applicable code. The water-resistive barrier shall be attached with flashing in such a manner as to provide a continuous water-resistive barrier behind the exterior wall veneer. The exterior facing of the Premier SlPs wall shall be covered with weather protection as required by the applicable building code or other approved materials. 4.2.1 1 Fire-resistance-rated Assemblies: 4.2.11.1 Fire-resistance-rated, limited load-bearing, restrained and unrestrained, floor and ceiling assembly using Premier SlPs with Box/Block Splines (Type S) - t hour (Figure 5). 4.2.11.1.1(ltem No. 1) Structural lnsulated Panels: Premier SlPs with minimum thickness of 81/a inches (2'10 mm). Panels shall bear the ICC-ES Evaluation Report number. Maximum uniform transverse load shall not exceed 77 percent of the allowable load in Table 1. 4.2.11.1.2(ltem No. 2) Gypsum Board: For ceiling (exposed side), U.S. Gypsum, Firecode (Type X) s/a-inch- ESR4624 | moet Widclv A and Trusted Pase 4 of 19 thict( (15.9 mm), 4-foot-wide (1.22 m) by 1O-foot-long (3.05 m), applied in two layers. lnner layer installed with gypsum long dimension parallel to Premier SlPs spline and offset a minimum of 24 inches (610 mm) from the Premier SlPs spline joints. Gypsum joints perpendicular to Premier SlPs spline shall be staggered in adjacent panels not less than 7 feet (2.1 m).lnner layer shall be secured to the OSB with No. 6 x 11la-inch (31.8 mm), Type S, bugle head drywalt screws spaced 12 inches (305 mnr) on center and irr rows 24 inches (610 mm) on center, Second layer installed at right angles to inner layer wth all joints offset not less than 24 inches (610 mm) from the inner layer. Second layer secured with No. 7 x 2-inch (50,8 mm), Type S, bugle head drywall screws spaced 12 inches (305 mm) on center and in rows spaced 16 inches (406 mm) on center. Gypsum board joints in the second layer shall be covered with paper joint tape and joint compound. Screw heads shall be covered with joint compound. 4.2.1 1.1.3 (ltem No. 3) Box/Block Sptine: M inimum 3-inch (76.2 mm) Bor/Block spline placed in preformed spline pockets at the edge of the SlP. Spline secured with not less than 0.113 inch diameter (2.87 mm)x 2 3/a inch (60 mm) long nailsspaced 6 inches (152 mm) on center on each side of Premier SlPs joint. 4.2.1 1.2 Fire-resistance-rated, lim ited load-bearin g wal I assembly using Premier SlPs with Lumber Splines (Type L) - t hour (Figure 6): 4.2.11.2.1(ltem No. 1) Structural lnsulated Panels: Premier SlPs with minimum thickness of 61/z inches (165 mm). Panels shall bear the ICC-ES Evaluation Report number. Maximum axial compression load shall not exceed 37 percent of the allowable axial load in Table 6. 4.2.11.2.2(ltem No. 2) cypsum Board: Standard Gypsum's Type SG-C, TE generation 3 (Type C) s/a-inch- thick (15.9 mm), 4-foot-wide (1.22 m) by '1O-foot-tong (3.05 m), applied vertically in a single layer on both sides of the Premier SlPs. Vertical gypsum joints offset a minimum of 12 inches (305 mm) from Premier SlPs spline joints. Gypsum secured to the OSB with '1sle-inch-long (41.3 mm) PC cupped head drywall nails spaced 12 inches (305 mm) on center vertically and 16 inches (406 mm) on center horizontally. Gypsum board joints are covered with paper joint tape and joint compound. Nail heads are covered with joint compound. 4.2.11.2.3 (ltem No. 3) Spline: Double 2xO #2 Hem-Fir dimensional lumber. Double lumber members shall be nailed together with 0.148-inch x 31/a-inch (3.76 mm x 82.6 mm) coated sinker nails ('l6d) spaced 24 inches (610 mm) on center staggered along the spline length. The double lumber spline shall be installed in the recesses between adjacent Premier SlPs and secured to the OSB with not less than 0.122-inch x 2-inch (3.1 mm x 50.8 mm) (6d common) nails spaced 6 inches (152 mm) on center. Caulk complying with ASTM C834 shall be apptied to the spline surfaces in contact with the EPS. 4.2.11.2.4(item No. 4) Wall Top Plate: Doubte 2xG #2 Hem-Fir dimensional lumber. The first plate shall be installed in a 3-inch-deep (76.2 mm) recess at the top of the Premier SlPs and secured to the OSB facings with 0.122-inch x 2-inch (3.1 mm x 50.8 mm) (6d common) nails spaced 6 inches (152 mm) on center. The first plate shall also be secured to each spline with two 0.148-inch x 31L-inch (3.76 mm x 82.6 mm) ('16d common) nails. The second plate shall be placed above the first plate and secured to the OSB facings with 0.122-inch x 2-inch (3.1 mm x 50.8 mm) (6d common) nails spaced 6 inches (152 mm) on center. The second plate shall also be secured to the first plate with 0.148-inch x 31/a-inch (3.76 mm x 82.6 mm) coated sinker nails (16d) spaced 16 inches (406 mm) on center staggered along the plate length. Caulk complying with ASTM C834 shall be applled to the plate surfaces in contact with the EPS. 4.2.11.2.5(ltem No.S) Wall Bottom Plate: Single 2x6 No. 2 Hem-Fir dimensional lumber. The plate shall be installed in a 11lz-inch-deep (38.1 mm) recess at the bottom of the panel and secured to the OSB facings with 0,122-inch x 2-inch (3,1 mm x 50.0 mm) (0rJ contnrur) nails spaced 6 inches (152 mm) on center. The plate shall also be seourcd to cach splrnc with two 0.148-inch x 3'r/,r-inch (3.76 mm x 82.6 mm) (16d common) nails. Caulk complying with ASTM C834 shall be applied to the plate surfaces in contact with the EPS. 4.2.11.3 One-hour Limited Load-bearing Wall Assembly Using Premier SlPs with Box/Block Splines (Type S) - t hour (Figure 7): 4.2.11.3.1 (ltem No. 1) Structural lnsulated Panels: Premier SlPs with thicknesses of 4 %, 6 Y., or 8 % inches (114, 165, or 21 0 mm) are used to construct a one-hour fire resistance rated wall assembly. The SIP core is recessed 1lzinches (38mm) from the bottom sip edge and lTzinches (38 mm) from the top SIP edge. The recesses receive nominally 2-by lumber bottom and top plates with a depth to match the core thickness. 4.2.11.3.2 (ltem No. 2) Splines: The SIP core is recessed on the vertical sides to receive Box/Block Splines in accordance with Section 3.2.5.1 of this report. A /, inch (13mm) diameter bead of Premier Low VOC Sealant is applied at all foam to foam and foam to wood interface per the manufacturer's details. The splines must be connected to the SlPs by fastening through the SIP OSB facing with not less than 0.113 inch diameter (2.87 mm) x 2 3/a inch (60 mm) long nails spaced 6 inches (152 mm) on center. 4.2.11.3.3 (ltem No. 3) Gypsum Board: The SlPs must be covered with two layers of 5/e inch thick (15.9 mm) Type X gypsum wallboard, complying with ASTM C1396, on each side. Where the panels are exposed to the exterior, the exterior layers of gypsum boards must be 5/8-inch-thick (15.9 mm), Type X gypsum sheathing complying with ASTM C1396. The verticaljoints of the first layer of gypsum board must be offset a minimum of 16 inches (406 mm) from the spline joint. The first layer of gypsum board must be fastened to the panel facing with 15/a inch long (41 .28 mm), Type W, self-piercing tapping screws complying with ASTM C1002, spaced 24 inches (610 mm) on center vertically and 16 inches (406 mm) on center horizontally. The second layer of gypsum board must be installed with 2 inch long (50.8 mm), Type W, self-piercing tapping screws complying with ASTM C1002, spaced 12 inches (305 mm) on center vertically, in rows offset 12 inches (305 mm) from screws securing the first layer of gypsum board, and 16 inches (406 mm) on center horizontally, in rows offset 8 inches (203 mm) from screws securing the first layer of gypsum board. The vertical joints in the second layer of gypsum board must be offset a minimum of 16 inches (406 mm) from vertical joints of the first layer of gypsum board. Exposed gypsum board joints must be covered with joint tape and joint compound and the exposed screw heads covered with joint compound in accordance with ASTM c840. 4.2.11.3.4 (item No.4) Wall Top Plate: The walltop plate consists of nominal 2-by spruce-pine-fir No. 2 or better lumber with a depth to rnatch the core thickness. The plate is connected to the SlPs by fastening through the SIP OSB facing with 8d box nails spaced 6 inches (152 mm) on center, on each side of the SlP. ESR4524 I Most Widelv Accepted and Trusted Paoe 5 of 19 4.2.11.3.5 (ltem No.S) Wall Bottom Plate: The wall bottom plate consists of nominal 2-by spruce-pine-fir No. 2 or better lumber with a depth to match the core thickness. The plate is connected to the SlPs by fastening through the SIP OSB facing with 8d box nails spaced 6 inches (152 mm) on center, on each side of the SlP. 4.2.11.3.6 This fire-resistance-rated wall assembly is limited to the heights shown in Table S.The maximum superimposed allowable axial compression load shall be no greater than the lesser of 1800 plf (26 kN/m) or 39% of the loads in Table 5. 5.0 CONDITIONS OF USE Premier SlPs as described in this report comply with the codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 lnstallation complies with this report and the approved construction documents. 5.2 This report applies only to the panel thicknesses specifi cally listed herein. 5.3 ln use panel heights/spans shall not exceed the values listed herein. Extrapolation beyond the values listed herein is not permitted. 5.4 The panels are produced in the production facilities in Puyallup, Washington, Belgrade, Montana, and Cottonwood, Minnesota under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with ICC-ES AC04 Acceptance Criteria for Sandwich Panels Approved June 2019 (editorially revised December 2020). 6.2 Reports of tests conducted in accordance with ASTM E119. 6.3 Reports of tests conducted in accordance with ASTM E455. ffiffiffi Box/Block Spline (Type S)Wffirm Engineered l-Beam Spline (TyPe l)WW 6.4 Reports of test conducted in accordance with NFPA 286. 7.0 IDENTIFICATION 7.1 Premier SlPs are identified with the following information: 7.1.1 fhe ICC-ES Evaluation Report number (ESR-4524) 7.1 .2 ln-plant quality assurance stamp 7.1.3 Company name (Premier Building Systems, LLC), or name of listees (Big Sky lnsulations, lnc., or Extreme Panel Technologies) 7.1.4 Project or batch number 7.2 Premier SlPs Low VOC Sealant is labeled with the words "for use with Premier SlPs (ESR-452a)." 7.3 Premier SlPs Screws are labeled with the words "for use with Premier SlPs (ESR-4524)." 7.4 Premier SlPs Tape is labeled with the words "for use with Premier SlPs (ESR-4524)." 7.5 l-beam splines are labeled with the words "for use with Premier Sl Ps (ESR-4524)." 7.6 The report holder's contact information is the following: PREMIER BUILDING SYSTEMS, LLC 18504 CANYON ROAD EAST PUYALLUP, WASHINGTON 98375 7.7 The Additional Listees' contact information is the following: BIG SKY INSULATION, INC. 15 ARDEN DRIVE BELGRADE, MONTANA 59714 EXTREME PANEL TECHNOLOGIES 475 EAST 4TH STREET NORTH COTTONWOOD, MINNESOTA 56229 wfi w Dimensional Lumber Spline (Type L)WW FIGURE 1-PREMIER SIP SPLINE fiPES ESR-4524 | Most Widetv and Trusted Page 6 of 19 w FIGURE 2_ZERO BEARING SUPPORT TABLE 1-MAXIMUM ALLOWABLE UNIFORM TRANSVERSE LOAD, ROOF/FLOOR (psf) - TYPE S SPLINEl,3 For Sl: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 'l psf = 0.0479 kpa. 1 Table values assume a simply supported panel with 11/z-inches (38.1 mm) of continuous bearing on facing at supports. permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load. Values do not include the dead weight ofthe panel. 2 Defleclion limit shall be selected by building designer based on the serviceability requirements of the structuie and the requirements of Spplicable building code. Values are based on loads of short duration only and do not consider lhe effects of creep. 3 Table values for 8-foot (2.44 m) spans apply to panels constructed with ihe OSB strength axis oriented either parallel or perpendicular to span direclion. Table values for other spans are based on the OSB strength axis oriented parallel to the span direction.aPanelsspanning 4fee|(1 .22m)shall beaminimumof 8-foot (2.44m)longspanningtwo4-foot(1 .22m)spans.s Panel thicknesses are based on overall (outside of facing to outside of fa;inir) with;7/16 inch OSB. \Men thickerfacings are used, the core remains the same thickness and the overall panel thicknesses increase. R PANEL THICKNESS5 (inches) DEFLECTION LIMIT, PANEL SPAN (feet) 44 I 10 12 14 16 18 20 22 24 4.5 L/360 100 32 23 18 14 11 u240 143 48 35 27 21 16 L/1 80 143 63 47 36 28 22 6.5 L/360 '105 51 38 29 23 19 't5 12 Lt240 162 76 57 44 35 28 23 19 L/1 80 191 80 61 50 42 36 30 24 8.25 L/360 120 67 51 40 32 26 22 18 15 13 Lt240 179 g4 71 57 48 40 33 27 23 19 L/1 80 179 94 71 57 48 41 36 32 26 22 10.25 L/360 '131 86 66 52 43 35 29 25 21 18 Lt240 168 94 75 63 54 47 41 36 32 27 L/1 80 168 94 75 63 54 47 41 36 33 28 12.25 u360 132 94 75 63 53 44 37 32 27 23 Lt240 163 94 75 OJ 54 47 42 37 34 3i L/180 163 94 75 63 54 47 42 37 34 31 ESR4524 I Most Widelv Accepted and Trusted Paqe 7 of l9 TABLE 2-MAxIMUM ALLOWABLE UNIFORM TRANSVERSE LOAD, WALL (PSf). TYPE S SPLINEI'3 For Sl: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 psf = 0.0479 kPa. 1 Table values assume an end-supported panel with zero bearing on facing at supports. Permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load. 2 Deflection limit shall be selected by building designer based on the serviceability requirements of the structure and the requirements of applicable building code. Values are based on loads of short duration only and do not consider the effects of creep. 3 Table values for 8-foot (2.44 m) spans apply to panels constructed with the OSB strength axis oriented either parallel or perpendicular to span direction. Table values for other spans are based on the OSB strength axis oriented parallel to the span direction. a Fanel thicknesses are based on overall (outside of facing to outside of facing) with a 7/16 inch OSB. When thicker facings are used, the core remains the same thickness and the overall panel thicknesses increase. PANEL THICKNESS4 (inches) DEFLECTION LIMIT2 PANEL SPAN (feet) 8 t0 12 14 16 18 20 22 24 4.5 L/360 32 23 1B 14 1'l Lt240 48 35 27 21 16 L/1 BO 55 44 36 28 22 6.5 L/360 51 38 29 23 19 15 12 Lt240 67 53 44 35 28 23 19 L/1 80 67 53 44 38 33 29 24 8.25 L/360 67 51 40 32 26 22 18 15 13 Lt240 75 60 50 42 37 33 27 23 19 u180 75 60 50 42 37 33 30 26 22 10.25 L/360 B3 66 52 43 35 29 25 21 18 u240 83 66 55 47 41 36 33 30 27 u180 83 66 55 47 41 36 33 30 27 12.25 L/360 89 72 60 51 44 37 32 27 23 Lt240 89 72 60 51 45 40 36 32 30 L/1 BO 89 72 60 51 45 40 36 32 30 ESR-4524 I Most Widoly Aoooptcd and Trusted Page 8 of 19 PANEL THICKNESSs (inches) DEFLECTION LIMIT2 PANEL SPAN (fe6t) 44 8 10 't2 14 16 18 20 22 24 8.25 L/360 132 136 93 60 50 40 31 21 19 16 u240 31 8-148-107"91 92' 75 59 45 31 27 23 UIBO 3't8^148^1 07^8/t8 60 41 36 30 10.25 u360 1Vt 1tt4-124-72 67 61 48 34 29 24 Lt240 336-164.124.'t07-96 B4 70 49 43 36 L/1 80 336.164-124*107*96 84-76 65 56 47 '12.25 L/360 258 143*1 03.B6 83 77.61 42 37 32 u240 31 8.143-1 03.93"85 77*68 59.54 46 L/1 80 31 8-143-1 03.93-85 77-68 59.54 49- TABLE 3-MAXIMUM ALLOWABLE UNIFORM TRANSVERSE LOAD (psf) - TYPE I SPL|NEl,3 ForSl: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 psf = 0.0479 kPa. lTable values assume a simply supported panel with 11l2-inches (38.1 mm) of continuous bearing on facing at supports. Permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load. Splines consist of one wood l-beam, 21l4-inch (57.2 mm) wide flange (minimum) with a depth equal to the core thickness, spaced not to exceed 48 inches (1219.2 mm) on center.2 Deflection limit shall be selected by building designer based on the serviceability requirements of the structure and the requirements of applicable building code. 3 Tabulated values for $-fool (2.44 m) walls apply to panels constructed with the OSB strength axis oriented either parallel or perpendicular to supports. Tabulated values for other lengths are based on the strong-axis of the facing material oriented parallel to the span direction.4 Panels spanning 4leet(1.22 m) shall be a minimum of I foot QAifl long spanning-a minimum of two 4-foot (1.22 m) spans. No single span condition is allowed. 5 Panel thicknesses are based on overall (outside of facing to outside of facing) with a 7/16 inch oSB. When thieker faeings are used, the core remains the same thickness and the overall panel thicknesses increase.*An asterisk (-) indicates the value shown is governed by the average peak load divided by 3. TABLE 4-MAXIMUM ALLOWABLE UNIFORM TRANSVERSE LOAD (psf) - TYPE L SPL|NE1,3 For Sl: 1 inch = 25.4 mm; 'l foot = 304.8 mm; 1 psf = 0.0479 kpa. rTable values assume a simply supported panel with 1llz-inches (38.1 mm) of continuous bearing on facing at supports. Permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load. Splines consist of No. 2 or better, Hem-Fir, 11lz inches (38.1 mm) wide with a depth equal to the core thickness, spaced to provide not less than two members for every 48 inches (1219.2 mm) of panel width.2 Deflection limit shall be selected by building designer based on the serviceability requirements of the struiture and the requirements of applicable building code. 3 Tabulated values for B-toot (2.44 m) walls apply to panels conslructed with the OSB strength axis oriented either parallel or perpendicular to supports. Tabulated values for olher lengths are based on the strong-axis of the facing material oriented parallel to the span direction.1 Panels spanning 4 leel (1 .22 m) shall be a minimum of 8 foot (2.4i m) long spanning- a minimum of two 4-foot (1 .22 m) spans. No single span condition is allowcd. 5 Panel thicknesses are based on overall (outside of facing to outside of facing) with a 7/16 inch OSB. When thicker facings are used, the core remains the same lhickness and the overall panel thicknesses increase.*An asterisk (.) indicates the value shown is governed by the average peak load divided by 3. PANEL THICKNESSs (inches) DEFLECTION LIMIT2 PANEL SPAN (feet) 4*I {0 12 14 t6 18 20 22 24 4.5 L/360 103 45 33 24 18 11 u240 225 68 47 34 26 17 L/1 80 297-91 61 45 34 23 6.5 L/360 307.129 57 42 34 25 20 15 Lt240 307-182"87 61 49 37 30 22 L/180 307-182*112-80 65 49 39 29 8.25 L/360 253 171 82 66 54 41 32 23 Lt240 288-1 BB-128 100 81 61 48 35 L/180 288.1 88-1 33.117.105 80 63 45 10.25 u360 286 1 88.117 101 80 5B 47 36 32 27 Lt240 326-1 88.'147-134"120 90 71 52 47 41 L/1 80 326.189*147-134.121 108.93 6B 61 53 12.25 u360 327-I 88.'t67.14'l 116 91 75 58 47 36 Lt240 327.1 88-'t67* 167- 1 53. 1 53- 132 132 1 10- 1 10. 97 83-69 53 L/1 80 327.1 88.o7 83-83 70 ESR4524 I Most Widelv Accepted and Trusted Paqe 9 of 19 PANEL THICKNESS6 (inch) PANEL SPAN (fEEt) I t0 12 l6 20 24 4.5 3,500 2,553 2,453 2.117 6.5 4,250 4,043 3,373 3,923 2,817 2,183 8.25 4,917 4,327 4,473 4,197 3,497 3,067 10.25 4,600 4,414 4,228 4,417 3,389 3,248 12.25 3,889 3,959 4,028 4,408 3,837*3,333 TABLE s-MAXIMUM ALLOWABLE UNIFORM AXIAL LOAD (plf) - TYPE S SPLINEI'2'3'4'5 For Sl: I inch = 25.4 mm; 1 304.8 mm; 1 psf = 0.0479 1 plf = 14.6 N/m 1 Splines consist of Box/Block splines not less than 7/re inch (1 1.1 mm) thick inserted below the facing on each side of the panel Permanent loads, such as dead load, 2 Uniform axial loads may Section 4.1.5 and Table 6. shall not exceed 0.50 times the tabulated load be applied in accordance with Section 4.1.4. Concentrated point loads shall be addressed in accordance with 3 Both facings must bear on the supporting foundation or structure. a Tabulated-values for g-foot (2.44m)walli apply to panels constructed with the OSB strength axis oriented either parallel or perpendicular to supports.- Limited byl/e inch (3.2 mm) deflection (compression). u the maximum allowable axial load is limited to 7'lo/o ';f lhe reported allowable axial load when used as shear walls in Table 1 1 . 6 panel thicknesses are based on overall (outside of facing to outside of facing) with a 7i16 inch OSB. Wtren thickerfacings are used, the core remains the same thickness and the overall panel thicknesses increase. TABLE c-MAXIMUM ALLOWABLE UNIFORM AXIAL LOADS (plf) - TYPE L SPLINET'2'3'4'5 For Sl: '1 inch = 25 I Splines consist of than two members mm; 1 foot = 304.8 mm; 1 psf = 0.0479 kPa; t plf = 14.6 N/m. No. 2 or better, Hem-Fir, 1llz-inches (38.1 mm) wide with a depth equal to the core thickness, spaced to provide not less for every 48 inches ('1219.2 mm) of panel width. Permanent loads, such as dead load, shall not exceed 0.50 times the TABLE 7-MAXIMUM ALLOWABLE AXIAL COMPRESSION POINT LOADS (lbs) - fiPE S SPLINEl'2'3'4 tabulated load. , nxiif foaOs shall be applied concentrically to the top of the panel through repetitive members spaced not more than 24 inches (609.6 mm) on center. Such members shall be fastened to a rim board, cap plate or similar member to distribute along the top of the Premier SlPs panel. 3 Both facings must bear on the supporting foundation or structure. a Tabulated-values for B-foot (2.44'i't) waiis apply to panels constructed with the OSB strength axis oriented either parallel or perpendicular to supports.. Limited by1/s inch (3.2 mm) deflection (compression) 5 The maxihum allowable axial load is limited to 51 7o of the reported allowable axial load when used as shear walls in Table 1 1 . 6 panel thicknesses are based on overall (outside of facing to outside of facing) with a 7/16 inch OSB. \Men thicker facings are used, the core remains the same thickness and the overall panel thicknesses increase. PANEL THICKNES56 (inch) PANEL SPAN (feet) I 10 12 t6 20 24 4.5 4,723 3,903 3,273 2,623 6.5 5,850 5,890 4,277 4,310 2,933 2,837 8.25 6,807 6,1 10 5,557 5,180 4,837 4,083 10.25 5,473 5,709 5,946 5,948 4,729-4,250 12.25 5,667 5,474 5,281 5,775-4,729"4,223 TOP PLATE CONFIGURATION 11/2" MINIMUM BEARING WDTH 3" MINIMUM BEARING WDTH Single 2x4 No. 2 or Better Hem-Fir Plate 2,040 2,450 Single 2x4 No. 2 or Better Hem-Fir ToP Plate with 11/e in. minimum thickness Cap Plates'6 4,030 4,678 For Sl: 1 inch = 25.4 mm; 1 lb = 4.45 N. 1 Top plate secured to facings as required in Section 4.2'3. 2 pe;manent loads, such as dead load, shall not exceed 0.50 times the tabulated load. 3 Concentrated loads shall be applied concentrically to the top of the panel. a Tabulated values are based on the strong-axis of the facing material oriented parallel to lhe span direction. 5 See Figure 3. 6 cap plite shall have a minimum stiffness of 1.3E and span the full width of the slP. ESR-4524 I Moat Widoly Aaocpted and Trusted Page 10 of 19 Top Plate Cap Plate Top Plate FIGURE 3-TOP PLATE CONFIGURATIONS TABLE 8_MAXIMUM ALLOWABLE UNIFORM PREMIER sIP HEADER VERTICAL LoADs (p|f) 4vr|NCH THROUGH l2rL INCH TH|CKNESSI,2 ForSl:1 inch = 25.4 mm; l foot= 304.8 mm; 1 psf = 0.0479 kpa; 1 ptf = 14.6 N/m 1 V€rtical loads only. Lateral loads shall be transferred to lhe edges ofthe openings through continuous plate(s) designed in accordance with accepted engineering practice. Permanent loads, such as dead load, shall noiexceedb.s0 times the'tabuiaied load.2 Tabulated values are based on the strong-axis of the facing material oriented perpendicular to the direction of header span.3 Minimum depth of facing above opening. n Deflection limit shall be selected by building designer based on the serviceability requirements of the structure and the requirements ofapplicable building code. 5 Panel thicknesses are based on overall (outside of facing to outside of facing) with a 7/16 inch OSB. When thicker facings are used, lhe coreremains lhe same lhickness and the overall panel thicknesses increase. HEADER DEPTH3,5 (inches) DEFLECTION LIMITl HEADER SPAN (feet) 4 6 8 l0 't2 U4BO 740 384 228 142 L/360 740 384 229 142 u240 740 384 229 142 18 L/4BO 798 574 385 311 u360 798 574 385 3't1 Lt240 798 574 385 311 24 L/4BO 886 629 429 361 L/360 886 629 429 361 Lt240 886 629 429 361 ESR-4524 I Most Widelv Accepted and Trusted Page 11 of 19 HEADER DEPTH3,6 (inches) DEFLECTION LIMIT4 HEADER SPAN (feet) 4 6 I l0 12 L/480 345 243 156 99 u360 450 295 190 125 Lt240 630 382 236 153 18 Lt480 705 388 254 235 L/360 750 482 302 281 u240 750 482 302 281 24 L/480 698 556 368 350 L/360 896 556 368 350 Lt240 896 556 368 350 TABLE 9-MAXIMUM ALLOWABLE UNIFORM HEADER LOADS (plf) (PANEL SPLICE A MINIMUM OF 6 INCH FROM EDGE OF OPENING) 41lz INCH THROUGH 12114 INCH THICKNESSIT For Sl: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 psf = 0.0479 kPa; 1 plf = 14.6 Nim 1 Vertical loads only. Lateral loads shall be transferred to the edges of the openings through continuous plate(s) designed in accordance with accepted engineering practice. Permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load. 2 Tabulated valuel are based on the strong-axis of the facing material oriented perpendicular to the direction of header span. 3 Minimum depth of facing above opening. 4 Deflection limit shall be selected by nuiioing designer based on the serviceability requirements of the structure and the requirements of applicable building code. s ianel thickness6s are based on overall (outside of facing to outside of facing) with a 7/16 inch oSB. When thicker facings are used, the core remains the same thickness and the overall panel thicknesses increase. TABLE 1O-ALLOWABLE IN-PLANE RACKING SHEAR STRENGTH FOR PREMIER SIPS SHEAR WALLS 4112 INCH THROUGH 12114 INCH THICKNESS WND AND SEISMIC LOADS IN SEISMIC OESIGN CATEGORIES A, B AND C1 For Sl: 1 inch = 25.4 mm; 1 plf = 14.6 N/m. i Shear strength values, as published in this table, are limited to assemblies resisting wind or seismic forces when the aspect ratio (height:width) does not exceed 2:1. ) Cn-orOs, hold-downs and connections to other structural elements must be designed by a registered design professional in accordance with accepted engineering practice. 3 Spline type at inierior pin'et+o-panet joints only, solid chord members are required at each end of each shear wall segment. o n'equir# connections must be made on each -side of the SlP. Dimensional or engineered lumber shall have an equivalent specific gravity not less than specified.i For ilesign to resist seismic forces, shear wall height-width ratios greater than 2:1, but not exceeding 3.5:1, are permitted for assemblies using lum6er splines provided the allowable shear strength values in this table are multiplied by Zwlh SPLINE TYPE3 FRAMING MINIMUM sG4 MINI MUM FACING CONNECTIONS4 ALLOWABLE SHEAR LOAD5 (pl0chord2'3 Plate2 Soline3 Box/Block or Lumber Spline (Type S or Type L) 0.50 0.1'13"x2-112" nails 6" on center 0 . 1 1 3"x 2-1 12" nails , 6" on center (7/16" OSB Faced x 3" wide Box/Block Spline) 0.113"x 2-'112" nails,6" on center 410 0.50 0.1 1 3"x 2-318" nails, 6" on center stagger (2 rows) 0.113'x 2-318" nails, 6" on center (7/16" OSB Faced x 3" wide Box/Block Spline) 0.1 13"x 2-318" nails, 6" on center 460 0.42 0.1 13"x 2-318" nails, 6" on center stagger (2 rows) 0.113"x 2-318" nails, 4" on center stagger (2 rows) (7/16" OSB Faced x 3" wide Box/Block Spline) 0.113"x 2-318" nails, 4" on center 700 o.42 0.148"x 2-318" nails, 6" on center stagger (2 rows) 0.148"x 2-318" nails, 3" on center (23132" OSB Faced x 3" wide Box/Block Spline) 0.148"x 2-318" nails, 3" on center stagger (2 rows) 1 000 ESR-4524 I Most Widoty Aaocptcd and Trusted Page 12 of 19 TABLE 11-ALLOWABLE IN-PLANE SHEAR FOR PREMIER SIPS SHEAR WALLS 4 THROUGH I21L |NCH THICKNESS IN SEISMIC DESIGN CATEGORIES A THROUGH tl, Fl, INCH 2,3,4,5 SPLINE TYPE BOTTOM PLATE TOP PLATE END POSTS PLATES TO POSTS FACING NAIL TYPE ALLOWABLE LOADS (olfl o Surface, Box/Block (23i32 OSB Faced) or Lumber, 3" widc Single 2x bottom plate (0.50 SG) Double 2x lumber (0.50 SG) 0.131 x3-114" llails 2 r'ows, 5 inch on center Double 2x lumber or Single 4x (0.50 SG) 0.131 x 3-1/4" rrails 2 rlws, 5 inch on center (2) 0.162 x 3 Nails 0.113"x 2-318" nails, 6" on center (3/4" edge distance)360 540 n 9urfacc, Box/Block (23132 OSB Faced) or Lumber, 3" wide Sittgle 2x lrullnrrr plate (0.50 SG) Dr-rrrhle 2x lumber (0.50 sG) 0.148 x 3" nails 2 rows, 6 inch on center Double 2x lumber or Single 4x (0.50 SG) 0.131 x 3" nails 2 rows, 5 inch on cenler (2) U.1ti2 x 3 Nails 0.1 13'x 2 3/8" nails, 2 rows, 4" on center, staggered (3/8" and 3/4" edge distance) o Surface, Box/Block (23132 OSB Faced) or Lumber, 3" wide Single 2x bottom plate (0.50 SG) Double 2x lumber or Single ax (0.50 SG) 0.148 x 3" nails 2 rows, 6 inch on center Double 2x lumber or Single 4x (0.50 SG) 0.131 x 3" nails 2 rows, 5 inch on center (2) 0.162x3 Nails 0.1 13"x 2-3i8" nails, 2 rows, 3" on center staggered (3/B" and 3i4" edge distance)720 6 Surface, Box/Block (23132 OSB Faced) or Lumber, 3" wide Single 2x bottom plate (0.50 SG) Double 2x lumber or Single ax (0.50 SG) 0.148 x 3" nails 2 rows, 5 inch on cenler Double 2x lumber or Single ax (0.50 SG) 0.131 x3-114" nails 2 rows, 5 inch on center (2) 0.162 x 3 Nails 0.1 1 3"x 2-318" nails, 2 rows,2" on center, staggered (3/8" and 3/4" edge distance)920 For Sl: 1 inch = 25.4 mm; 1 plf = 14.6 N/mlEnd posts and splines must be framed to provide full end bearing in accordance with IBC Section 2304.3. OSB facings must be fully !eaf19.9n structural supports. A hold-down device must be attached to the vertical studs at each end of the shear wall assembly. 'lnstallalion of the hold-down devices must be in accordancewith the hold-down device manufacturer's instructions and as designed bythe registered design professional. 3The tabulated allowable racking shear loads are for slPs installed with the strong axis of the osB slp facings in either the vertical orhorizontal direction. aSplines must be as described in Section 3.2.5 of this report.sNails shall be installed on both sides of spline joint, bottom plate, top plate, and vertical boundary members (end posts) of the Slpshearwall. NailsmuslcomplywithASTMFl66TandhaveaminimumbendingyieldstrengthottOOtsi (689'Mpa).6This installation configuration is recognized for use as both load-bearing and -nonload-bea-ring sheanrualls in Seismic Design CategoriesA, B, C, D, E, and F with the seismic design coefficients of R=6.5; Systeh Overstrength Factdr, Oo=3.0; Deflection Amptifiiation Fictor, Cd=4.0 under the following provisions: a. For design to resist seismic forces, shear wall height-width ratios greater than 2:1, but not exceeding 9.5:i, arepermitted for assemblies using lumber splines provided the allowable shear strength values in this tible are multiplied by 2wlh.b. The shearwalls are supported by a rigid support, such as a concrete foundation.c. The wall SlPs must be installed in a manner such that both facings of lhe wall SlPs are equally and uniformly restrained at the top and bottom of the SlPs. The member, element or structure supporting th-e shear wall and the vertical restraint provided to the facers of the SlPs at the top and bottom of the wall SIF must be designed and detailed by a registered design professional.d. When used as load-bearing SlPs, the allowable axial load must be determined in accordance with Table 5 or 6 of this report.e. End posts must be designed by registered design professional. ESR4524 I Most Widelv Accepted and Trusted Page 13 of 19 TABLE 12_MAXIMUM ALLOWABLE IN.PLANE SHEAR FOR DIAPHRAGMS SUBJECTED TO WIND OR SEISMIC LOADINGI'5 ForSl:1 inch=25.4 mm; 1 lb=4.45 N; 1 plf ='14.6 N/m. 1 The maximum diaphragm length{o-width ratio of shall not exceed 4:1. Load may be applied parallel to continuous panel joints. 2 Ends of individual pan6ls arJrequired to be supported as required in Tables 1, 3 and 4. Specified fasteners are required through both faces of panels on both sides of joint where panels are joined over a support. See Figure 4A. 3 At unsupported interior panel{o-panel joinis, specifieil fasteners are required on the top of the panels on both sides of panel joint. See Figure 48. a Eoundary spline shall be solid 11lz inches (38.1 mm) wide, minimum, and have a specific gravity of 0.42 or greater' Specified spline fasteners ire required through both facings. See Figure 4C. Ends of individual panels are required to be supported as required in Tables 1, 3 and 4. 5 biaphragms shall be designed by a registered design professional in accordance with accepted engineering practice. Spllne Attachment (per table) Boundary Spllne Attachment Spllne (per table) Boundary Support Attachment (per table) lnterior Support Boundary Support Support Attachment (per table) FIGURE 4A_INTERIOR SUPPORT FIGURE4-DIAPHRAGM CONNECTION TYPES FIGURE 4B_BOXBLOCK SPLINE FIGURE 4C_BOUNDARY MIN IMUM CONNECTIONS2 ALLOWABLE SHEAR LOAD (plfl G' APPARENT SHEAR STIFFNESS {lbf/in) MAXIMUM ASPECT RATIO lnterior Supports2 (Fiqure 4A) Box/Block (Fioure Spline3 4B) Boundaryl (Fiqure 4C) SuDDort Spline PBS No. 14 SIP Screw with l" penetration 1 2" on center 0.1 1 3" x 2.5" nails, 3" on center 7116" x3" OSB Spline PBS No.14 SIP Screw with l" penetration 1 2" on center 0.113" x2.5" nails, 6" on center 430 24000 4:'l PBS No.14 SIP Screw with 1" penetration 1 2" on center 0.113" x 2.5" nails, 3" on center, 2 rows, staggered 7116" x3" OSB Spline PBS No.14 SIP Screw with 1 " penetration 3" on center 0.113" x2.5" nails, 4" on center 460 30300 4:1 PBS No.14 SIP Screw with 1" penetration 2" on center 0.1 13" x 2.5" nails, 3" on center, 2 rows, staggered 7/16" x 3" OSB SDline PBS No.14 SIP Screw with 1 " penetration 2" on center 0.113" x2.5" nails, 1.5" on center 655 41 300 4:1 PBS No.14 SIP Screw with l" penetration 4" on center 0.1 13" x 2.5" nails, 3" on center, 2 rows, staggered 7/16" x 3" OSB SPline PBS No.14 SIP Screw with l" penetration 4" on center O.1'13" x2 .5" nails, 3" on center 795 93700 3:1 PBS No.14 SIP Screw with l" penetration 4" on center 0.113" x 2.5" nails, 6" on center, 2 rows, staggered 23132" x4" OSB Spline PBS No.14 SIP Screw with 1" penetration 4" on center 0.113" x2.5" nails, 6" on center 1 130 1 10600 3:1 ESR,4524 I Most Wdelv Accepted and Trusted Paqe 14 of 19 Load-Bearing, Restrained Floor/Ceiling Assembly Rating - 1 Hour Load-Beari ng, Unrestrained Floor/Ceili ng Assembly Rating - I Hour VerticalSection FIGURE s-ASSEMBLY DRAWING FOR FIRE RESISTANCE SECTION 4.2,11.1 Load-Bearing Wall Assembly Rating - 1 Hour Horizontal Section Section A FIGURE G_ASSEMBLY DRAWING FOR FIRE RESISTANCE SECTION 4,2.11.2 Load-Bearing WallAssembly Rating - 1 Hour FIGURE 7-ASSEMBLY DRAWING FOR FIRE RESISTANCE SECTION 4,2,11.3 rc0 EVAL IIA]ION SI RVI Ct' ICC-ES Evaluation Report ESR-4524 City of LA Supplement Relssued February 2023 Revlsed January 2025 This repoft is subject to renewal February 2025. www.icc-es.orq I (S0O) 423-6587 | (562) 699-0543 A Subsidiary of the tnternational Code Council@ DIVISION: 06 OO 0O-WOOD, PLASTICS AND COMPOSITES Section: 06 12 0O-Structural Panels REPORT HOLDER: PREMIER BUILDING SYSTEMS, LLC EVALUATION SUBJECT: PREMIER STRUCTURAL INSULATED PANELS (SIPS) 1.0 REPORTPURPOSEANDSCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Premier SlPs, described in ICC-ES evaluation report ESR-4524, have also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). Applicable code editions: . 2023 City of Los Angeles Building Code (LABC) . 2023 City of Los Angeles ResidentialCode (LARC) 2.0 CONCLUSIONS The premier SlPs, described in Sections 2.0 through 7.0 of the evaluation report ESR-4524, comply with the LABC Chapters 7,23 and 26, and the LARC, and are subject to the conditions of use described in this supplement. 3.0 CONDITIONS OF USE The premier SlPs described in this evaluation report supplement must comply with all of the following conditions: . All applicable sections in the evaluation report$Bl[@[. o The design, installation, conditions of use and identification are in accordance with the2021 lnternational Building Code@ (lBC) provisions noted in the evaluation report ESR-4524. r The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. . Under the LARC, an engineered design in accordance with LARC Section R301.1.3 must be submitted. r premier Slps may be used in the construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban lnterface Fire Area, provided installation is in accordance with the 2021 tnternational"Building Coded (lBC) provisions noted in the evaluation report, the additional requirements of LABC Sections 701A.3, 7054 and 7074, as applicable, and the following conditions: . The premier Structural lnsulated Panels (SIPS) may be used as a component of a Class A classified roof assembly when installed in accordance with LABC Section 7054 and specifically recognized in an ASTM E108 or UL 790 listing approved by the code official. r The premier Structural lnsulated Panels (SIPS) may be used as a component in exterior wall construction in accordance with LABC Section 7074 when installed as described in Sections 4.2.11 .2 and 4.2.11 .3 of the evaluation report ESR-4524 or when specifically recognized in an ASTM E1 19 or UL 263 listing approved by the code official for a minimum 1-hour fire-resistance-rated (from the exterior side) wall assembly. r premier Slps may be used in the construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wldland-Urban lnterface Fire Area, provided installation is in accordance with the 2021 ICC-ES Evqluqtion Reports arc not to be constmerl as represenling qesthetics or any o,her attibutes not specrfically addtessed, nor are they to be constued qs an endorsement ofihe subiect ofthe report or d rccomnlendalionfor ils use. There is no u'atanty by ICC nvalualion Sevice, LLC, express or implied, as lo anyfinding or olher matler in lhis report, or as to any producl covered by lhe report. Copyright @ 2025 ICC Evaluation Service, LLC. All rights reserved. Nrril sfruffii *# Page 15 of 19 ESR4524 Gity of LA Su pplement I Most Widelv Accented and Trusted Paqe 16 of 19 lnternational Residential Code@ (lRC) provisions noted in the evaluation report, the additional requirements of LARC Sections R337.1.3, R337.5 and R337.7 of the LARC, as applicable, and the foliowing conditions: r The Premier Structural lnsulated Panels (SIPS) may be used as a component of a Class A classified roof assembly when installed in accordance with LARC Section R337.5 and specifically recognized in an ASTM E'108 or UL 790 listing approved by the code official. r The Premier Structural lnsulated Panels (SIPS) may be used as a component in exterior wall construction in accordance with LARC Section R337.7 when installed as described in Sections 4.2.11.2 and 4.2.i1 .3 of the evaluation repof FSR-41i24 r-rt wlrcrr specifically recognlzed ln an,ASTM E11g or UL ?63 lieting approvcd by thc code official for a minimum 1-hour fire-resistance-rated (from the exterior side) wall assembly. This supplement expires concurrently with the evaluation report, reissued February 2023 and revised January 2028. IKH rc0 IVALU/ITION SIRVICI' ICC-ES Evaluation Report ESR-4524 CA Supplement d Exterior Wildfire Exposure Rer.ssued February 2023 Revr.sed January 2025 This repoft is subject to renewal February 2025. www.icc-es.orq | (800) 423-6587 | (562) 699-0543 A Subsidiary of the tnternational Code Council@ DIVISION: 06 00 00-WOOD, PLASTICS AND COMPOSITES Section: 06 12 O0-Structural Panels REPORT HOLDER: PREMIER BUILDING SYSTEMS, LLG EVALUATION SUBJECT: PREMIER STRUCTURAL INSULATED PANELS (SIPS) 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Premier SlPs, described in ICC-ES evaluation report ESR- 4524,have also been evaluated for compliance with the code(s) noted below. Applicable code edition(sJ: | 2022 California Building Code (CBC) For evaluation of applicable Chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) Al(A: Califoinia Department of Health Care Access and lnformation (HCAI) and the Division of State Architect (DSA), see Sections 2.1 .1 and2.1.2below. . 2022 California ResidentialCode (CRC) 2.0 coNcLusloNs 2.1 CBC: The Premier SlPs, described in Sections 2.0 through 7.0 of the evaluation report ESR-4524, comply with CB^C Chapters 7, 16' and 26, provided the design and installation are in accordance with the 2021 lnternational Building Code@ (lBC) provisions noted in the evaluation report and the additional requirements of CBC Chapters 16 and 26, as applicable. premier SlPs may be used in the construction of new buildings located in any Fire Hazard Severity Zone within State Responsibil1y Areas or any Wldland-Urban lnterface Fire Area, provided installation is in accordance with the 2021 lnteinational'Buitding Coded(lBC) provisions noted in the evaluation report and the additional requirements of CBC Sections 70'1A.3, 705A and 7074, as applicable, and the following conditions. . The Premier Structural lnsulated Panels (SIPS) may be used as a component of a Class A classified roof assembly when installed in accordance with CBC Section 7054 and specifically recognized in an ASTM E108 or UL 790 listing approved by the code official. r The Premier Structural lnsulated Panels (SIPS) may be used as a component in exterior wall construction in accordance with CBC Section 7074 when installed as described in Sections 4.2.11.2 and 4.2.11.3 of the evaluation report ESR-4S24 or when specifically recognized in an ASTM E119 or UL 263 listing approved by the code official for a minimum 1-hour fire-resistance-rated (from the exterior side) wall assembly. 2,1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. ICC-ES Evaluation Reports are not to be constmed as representing aesthetics or atry olher qltibules nol specifically addressed, nor are they to he construed as an endorsement ofihe subiect of the report or q recommendqtion for ils use. There is no u'arranty by ICC Evaluation Senice, LLC, express or implied, as to anyfnding or other maller in lhis report, or as to any product covered by lhe reporl' Copyright @ 2025 ICC Evaluation Service, LLC AII rights reserved N-aelp- ;R;,;I-:=lj.*: Page l7 of 19 ESR4524 CA Su lement I Mos/ Wirtclv AccenterJ and Trusted Paqe 18 of 18 2.2 CRC: The Premier SlPs, described in Sections 2.0 through 7.0 of the evaluation report ESR-4524, comply with CRC Sections R301 and R316, provided the design and installation are in accordance with the 2021 tnternational Residenta/ Code@ (lRC) provisions noted in the evaluation report. Premier SlPs may be used in the construction of new buildings located in any Fire Hazard Severity Zone within State Responsibility Areas or any Wildland-Urban lnterface Fire Area, provided installation is in accordince with the 2021 lnternational Residential Code@ (lRC) provisions noted in the evaluation report and the additional requirements of CRC Scctiong R337.1,3, R337,5 and R337.7, as applloattle, arrrl llre fr,rllr.rwirrg cr.rrrditiorrs; r The Premicr Strtte;tltral lnsulated Panels (SIPS) may be uaed as a component of a Class A olacsificd roof assembly when installed in accordance with CRC Section R337.5 and specificaily recognized in an ASTM E108 or UL 79b listing approved by the code official. o The Premier Structural lnsulated Panels (SIPS) may be used as a component in exterior wall construction in accordance with CRC Section R337.7 when installed as described in Sections 4.2 .11 .2 and 4.2.11 .3 of the evaluation report ESR-4524 or when specifically recognized in an ASTM E1 19 or UL 263 listing approved by the code official for a minimum 1-hour fire-resistance-rated (from the exterior side) wall assembly. This supplement expires concurrently with the evaluation report, reissued February 2023 and revised January 2025. IKH rcc I VAI UAII()N sr RvtcE' ICC-ES Evaluation Report ESR-4524 IWUIC Supplement /ssued October 2024 Revised January 2025 This report is subject to renewal February 2025. www.icc-es.orq | (800) 423-6587 | (562) 699-0543 A Subsidiary of the tnternationat Code Council@ DIVISION:06 00 00-WOOD, PLASTICS AND COMPOSITES Section: 06 12 00-Structural Panels REPORT HOLDER: PREMIER BUILDING SYSTEMS, LLC EVALUATION SUBJECT PREM|ER STRUCTURAL INSULATED PANELS (SIPS) 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that Premier Structural lnsulated Panels (SIPS), described in ICC-ES evaluation report ESR-4524, has also been evaluated for compliance with the codes noted below: Applicable code editions: . 2024,2021 and 2018 tnternationalWildland-Urban lnterface Code (lWUlC) 2.0 coNcLUSloNs The Premier Structural lnsulated Panels (SIPS), described in Sections 2.0 through 7.0 of the evaluation report ESR-4524, may be used in the design and construction of new buildings located in Wldland-Urban lnterface areas under the International Wildland-Urban tntdface Code (lWUlC) Sections 504, 505, and 506, provided the design and installation are in accordance with the 2024,2021 and 2018 Internationa! Wildland-tJrban lnterface Code (lWUlC), the design and installation provisions noted in the evaluation report ESR-4524, as applicable, and the following conditions: j. The Premier Structural lnsulated Panels (SIPS) may be used as a component of a classified roof assembly in accordance with IWU|C Sections 504.2,505.2 and 506.2 and specifically recognized in an ASTM E108 or UL 790 listing approved by the code official. 2. The premier Structural lnsulated Panels (SIPS) may be used as a component in exterior wall construction in accordance with IWUIC Sections 504.5, ltem 1 or 505.5, ltem I when installed as described in Sections 4.2.11.2and 4.2.11 .3 of the evaluation report ESR-4524 or when specifically recognized in an ASTM E'l 19 or UL 263 listing approved by the code official for a minimum 1-hour fire-resistance-rated (from the exterior side) wall assembly. This supplement expires concurrently with the evaluation report ESR-4524, reissued February 2023 and revised January 2025- ICC-ES Evaluation Reports qre not to be construed qs representing aeshetics or any other altilbules not specifically addressed, nor are lhey lo be construed as an endorsement ofihe subiect of the reporr or a recommendqtion for ils use. 'l'here is no u,arranty by ICC Evaluation Senice, LLC, express or implied, as lo qnyfinding or other mqller in lhis report, or qs lo any producl covered by the rcport Copyright @ 2025 ICC Evaluation Service, LLC. All rights reserved. W -riltp-;F,F*I1F.^.:: Page 19 of 1 9