HomeMy WebLinkAboutConditions of PermitCONDITIONS OF P ERMIT
BLRE-03 -25-9124
BRETT & MAURA WAMSLEY
914 sq ft Residential Addition
54 Pine St
Cooperton Twnste, Blk 9, Lot 27-29
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)
AND 2018 INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COU NTY BU I LDING REOU I REM ENTS". NU MBER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMTTTTNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL DOWNCAST LIG.HTING TO BE DOWNCAST AND SHIELDED.
S) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE
MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST
SERVICE AND LOCAL FIRE DISTRICT. SEE GARFIELD COUNry COMMUNITY DEVELOPMENT
DEPARTMENT WEBSITE FOR FURTH ER I NFORMATION.
6) OPEN HOLE SOTLS REPORT REOUTRED AT FTRST FOOTTNG tNSPECTION, 3,000 PSF SOIL
BEARING CAPACIry.
7) PRE-ENGTNEERED ROOF TRT.ISSES. HAVE ENGTNEERING FOR BUTLDTNG TNSPECTOR AT
TIME OF FRAME INSPECTION.
B) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO FINAL BUILDING INSPECTION &
CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL / SIGN-OFF FROM GARFIELD
COUNTY PUBLIC HEALTH DEPT.
9) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS
REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE _ INCLUDING PROVIDE
ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH
MINIMUM SETBACK REOUIREMENTS FOR RU ZONE DISTRICT.
1O) CURRENT SCOPE REVIEWED AS A ONE-FAMILY DWELLING WITH PRIVATE RESIDENTIAL
USES ALLOWED IN RURAL ZONE DISTRICT. FUTURE CHANGE TO BUILDING USE OR
OCCUPANCY, SHALL BE SUBJECT TO A NEW BUILDING PERMIT AND LAND USE CHANGE
PERMIT IN ACCORDANCE WITH ADOPTED CODES AND LAND USE REGULATIONS IN
EFFECT AT TIME OF FUTURE WORK.
NlI
s\
N