Loading...
HomeMy WebLinkAboutOWTS Permit Card Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 1155 CR 237, Silt Parcel No.: _212725300072 Owner Name: James & Connie Baker Owner Phone: (970) 920-2100 Designed By: CTL Thompson, Inc. Designer Phone: (970) 945-2809 Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 420 ft 2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9140______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _04/10/2025____________________ Expiration Date_04/10/2026_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CTL Thompson, Inc. February 21, 2025. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new three-bedroom residence. The irrigation ditch running to the West of the gravel driveway must be lined to reduce the setback to the proposed septic tank location. The system will consist of a new, three-compartment 1,250-gallon septic tank set level with access at grade and a screened high-head pump in the third chamber. Effluent will be pumped to two level manifolds that will distribute effluent to 576 ft2 of STA. Both the sewer line and effluent line are to be entirely encased as described by Garfield County OWTS Regulation 43, Table 7-2, Note 2. The new STA will consist of two gravel-less chamber beds, each bed consisting of 4 rows of 6 chambers (24 chambers per bed, and 48 chamber total). Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 5/32-inch orifices 5-feet on center and the laterals ending in 90-degree sweeping bends and flushing valves at the distal end of the laterals. Laterals are to be hung from the underside of the chambers. The orifices are to be facing upward, except for the last orifices (which shall face downward and be equipped with orifice shields for drainage purposes). Inspection ports are to be installed at each corner of each bed. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 04/10/2025 Issued By: Garfield County Environmental Health Department Date