Loading...
HomeMy WebLinkAboutCorrection Letter&rrehbn h/h- Colleen Wirth From: Sent: To: Cc: Subject: Attachments: Colleen Wirth Monday, March 3,2025 11:41 AM mattjurmu bouldercs.com; hannawit@outlook.com Ernest Kollar; lisabecchetti@hotmail.com; jkeithbryan@yahoo.com BLRE-02-25-9067 - Bryan Becchetti residence is PENDING Building Code Requirements - Residential.pdf BLRE-02-25-9067 - 3030 Etk Springs Dr Lot 42 For Lot 42Elk Springs project team: Hetto, this is a message from Garfiel,d County Ptans Examiner, Cotteen Wirth. BU I LDI NG APPLICATION REVIEW U PDATE: Structural ptan review is completed with no required corrections. Thankyou. Zoningcomptiance review is compteted with no required corrections. Thankyou. REQUTREp CORRECTTONS 1. Please provide written ctarification on pool spa scope. 1 .a. ls the outdoor spa pool noted on C1.0 inctuded under the current buitding application BLRE-02-25-9067 scope? 1 .b. Witt the outdoor spa pool be constructed AND finished when the general contractor schedutes the buitding finat I C.O. final inspections? 2. Resubmit (2) FULL SIZE PAPER COPIES of AMENDED sheet "A 01 ftoor plan - tiving space" to inctude a code comptiant "office" area. PLANS EXAMINER FEEDBACK: "Office" on A 01 ftoor ptan does notcomptywith Garfietd County's 2015 lRC, Section R304, and R304.1 minimum area for habitabl,e rooms. Architect of Record / Design professiona[ encouraged to view 2015 IRC section R304.1 and chapter 2 definition for habitabte spaces. Submitted office is less than 70 sq ft with room enctosed by doorway. (Architect and owner may wantlo consider en[arging the enctosed room space and/or remove DOOR "24" plus some portion of interna[ room partition so said "Office" becomes open to the adjoining'haltway'. Ptease discuss desired ftoor ptan Layout with owners and submit reptacement sheets A 01) 3. Submit a REVISED and CORRECTED MANUAL S REPORT that lists an accurate SITE ELEVATION ANd COTTECIEd WINTER DESIGN TEMPERATURE. PLANS EXAMINER FEEDBACK: Etevation on C1.0 at 7,035 ft etevation white the received ManuaI S Report (with tower etevation of 6,896 sq ft and lesser winter design temperature at minus 2 degrees). Materials do not appear to be coordinated across the entire buitding apptication set. lnasmuch as the StructuraI Engineer of Record indicates a snowload design to accommodate home placement above 7,000 ft elevation - Garfietd County presumes the elevation on C1.0 at 7,035 ft is correct? lf so, then ptease have MANUAL S Comptiance Report (February 3,2025) updated with corrected ELEVATION data and a CORRECTED winter design 1 temperature of minus 16 degrees. We are concerned the ptanned mechanicaI design may not be sufficient. Buitding Code Requirements PDF atso attached. Wintar Deeign Temperature: Minus 2 - Up to 70O0 ft. elevation Minus 16 - Over 7000 ft. elevation NEXT ACTION STEPS: Ptease submit requested items 1 - 3 in one comprehensive resubmission package to our Garfietd Gounty Community Devetopment front desk in downtown Gtenwood Springs. Onty responses to items 1 - 3 are requested at this time (PLEASE DO NOT print and submit FURTHER PAGES FROM THE PLAN SET where no corrections or changes appty. Sl.ip sheeting witt occur by ptans examiner during the next review, thank you). Golleen Wirth Buitding Ptans Examiner Garfietd Gounty Community Development 108 8th Street, Suite 401 Gtenwood Springs, CO 81601 (970) 945-1 377 ext 1 61 0 cwi rth@ga rf ie [d co u ntyco.gov 2