HomeMy WebLinkAboutBlower Door Test ReportResidential Air Infiltration Test Report
Test date:4/4/2025
Project name:Ditlow Residence
Address:3683 County Rd 241, New Castle
Garfield
Code:2018 IECC
Conditioned volume:68,858 Cubic Feet
Attic:Non-vented
Crawlspace:conditioned
Garage:excluded
Measured airflow:893 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:65
Temperature; Outside:48
Elevation:5,597
Corrected airflow:892 CFM50*Cubic Feet per Minute at 50 Pascal
2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:0.8 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
Final blower door test. Passes the 2018 IECC infiltration requirments.