Loading...
HomeMy WebLinkAboutBlower Door Test ReportResidential Air Infiltration Test Report Test date:4/4/2025 Project name:Ditlow Residence Address:3683 County Rd 241, New Castle Garfield Code:2018 IECC Conditioned volume:68,858 Cubic Feet Attic:Non-vented Crawlspace:conditioned Garage:excluded Measured airflow:893 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:65 Temperature; Outside:48 Elevation:5,597 Corrected airflow:892 CFM50*Cubic Feet per Minute at 50 Pascal 2015 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:0.8 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. Final blower door test. Passes the 2018 IECC infiltration requirments.