Loading...
HomeMy WebLinkAboutApplicationGarfield County 1: Commu nlty Development Dcparfttent MAI{ 'l 7 ,ltl'15 108 gth Street, sultertgliqr:q;i, g ., .., ;rI r i :. GlepwoodSprlngs,co81m1 ,, ,,. '- ' .,,1 i,1,1,,1 ;ri:iil {970f 945+212 $l{AR 2 7@;,,,, Demolition trr Reroof Contractor:WESTERN SLOPE BUILDERS Phone:1970 16184043 Mailing Address:po Box 1031, GLENWOOD SPRINGS, CO 81602 EmailAddrccs:TAYLOR@WE STERNSLOPEBU I LDERS.COM Archltect BRAD JORDANI/JORDAN ARCHITECTURE Phone:(970 16186690 MailingAddress:PO BOX 1031, GLENWOOD SPRINGS, CO 81602 Emall Address:BRADJORDANARCH ITECT@GMAIL.COM EnBineer:STEVE EDMISTON/MTCG Phone:.206 r9107766 Mailing Address:PO BOX 1577, BASALT, CO 81621 Email Address:sTEVE@MOUNTATNTOWNCG.COM i , I ! !j Ij i I 1 I BUILDING PERMIT APPLICATION Manufactured Home lnstaller:NIA Phone;{ } MallingAddress: Email Address: ._ Descrlbe Workl NEW SINGLE FAMILY RESIDENCE Job Address:1422HIGH ASPEN DRIVE Aseessor's Parcel f{umber:218725204013 Sub.HIGH ASPEN RANCH bt 13 dock owne/s valuation of Itvor x, * 4 I &5 *4 , -l L Propefi slre (sc. Ft. or Acres|:35.821 AC 5q. Ft. of Buildln$# of floors: 1 Glrs*Addition Garagc: 4416 Helglrt;20'sn Detached PRCtEgr, DETA$S.Silnf t$ GD Septic: fype of Ueatt Gas Propane I Community iteit.i. -' . iermit f: Other i i I I i , Drlveway i Permit; ilqrs - _ Authorl!% This application tor i atrliing eermit muii 6e signed oy itre owner of ihe property, described above, or an authorized agent. lf the signature below ia not that of the Owner, a soparate letter of authority, signed by the Owner, must be provided with this Appllcation. l*gal Access. A Building Permit cannot be issued without proof of legal and adequatr access to the property for purposes of inspections by the Building Division. other Permits. Multiple separate permits may be required: {1) State Electrical permit, (2) County OWTS permit, {3) another permit required for use on the property identified above, e-g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 1g0 days of the date o[ issuartce arrd i[ work ls suspended or abandoned for a period of 180 days after commencement. ccRaf{eAno1{ I hereby certify that I have read this Application and that the information contained above is true and correit. I undersFand that the Building Division accepts the Application, along with the ptans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application. a Building Permit will be issued granting permission to me, as owner, to construct the structure(s) and facilities detailed on the submifcals reviewed by the Rrrilcling Division. tn consideration of the issuance of the Euilding Permit, I agree that I and my agents will comply with piovisions of any federal, state, or local law regulating the work and the Garfield County Building Code, OWTS regulations and applicable land use regulations (County Regulation(s))- All County development requiring a permit, except for residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the BuildingPermit may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure{s} and facility(ies}, described above, are not in compliance with County Regulation(s) or any other applicable law. lherebvgrantnprmi<cinntnthaArrilr{in-niui.;^^+^^h}^,+L^ r----!L-r, .-i !'!re eu,'vrilb rv srrrsr rrrv !,lelrEr ry, uElLiluFil .lilrrvg. (ur lnspecl tne work, Ifurther acknowledge that the issuance of the Building Permit does not prevent the Building official from: (1t requiring the correction of errors in the submittals, lf any, discovered after issuance; or {2} stoppinj construction or use of thestructure(s) or facility(ies) if such is in violation of county Regulationtsl or any other applicable law. Review of thisApplication, including submittals, and inspections of the work by the Buildin6 Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, Iacknowledge that resPonsibility for compliance with federal, state and local laws and county Regulations rest withme and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I hereby acknowledge that I have read and understand the Notice and Certificatlon abovg as well as, haveprovided the regulred lnformatlon which ls correct and accurate of my knowledge, ll { h.lr b e Property Onner Print and Date oF.figAf I I Speclal Condltions: Adjusted valuatlon: 4q2. sos.zo Plan Chedr Fee: 2 otc .<e P€rmlt Fee: a \4.55 Manu. Home Fee:Mlsc. Fees: Total FLes: 5 Ztt.ol Balance Oue: 'Lq.tl ALiE-ql raA BP filo: SaQt-qtl'3 OWTS No: 5etbacks:Const.Zonlne: P. BUll-Dlr{G / PtAt{Ntt{G DtvtstoN : ocCGroup: fVC o 4 -2s."5 Date ENERGY COMPL|ANCE SHEET REQUIREIIIENTS: Effective June 30, 2O2SPlease provide details showing how building complies / meets Garlietd County's adopted 2018 IECC and Climate Zone 5. Depict and show outline the structure's building thermalenvelope. Outline should clearly show portions of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining unconditioned outside this envelope) Energy Compliance Plan should further include: Chosen Energy Compliance Path. EBPscr!E!!ve:, Cross Sections of insulated assemblies including the selected material/ R-Value and U-Values to comply with IRC Table R4O2.1.2r U--FactorAltemative: Provide a ResCheck Reporto Total U-FactorAltemative: Provide softnare generated submittaldesign reports and inspection checklist for any RESNET ERI index or other performance path designs Air sealing details around openings, pipes, penetrations, joints Fenestration U-factors Provide mechanical system design details including proposed efficiency rate$, types of equipment, fuel types, locations Energy ef{icient lighting specifications - 90% to be high-efftcacy (LED compties) ManualJ Report required for new building structures and new equipment installations. STRUCTURAL PLANS: Please provide the following information on the structural plans.. SOIL$ REPORT - lf the project is located in a subdivision with a final plat reguiring site specific soils investigation report or if Structural plans make a specific reference to a soils report, ihen a copy of the soils report is required to submit a building permit application.e Design specifications to include roof and dec* snow load, wind and seismic design and frost depth.r Foundation plan showing complete footing and foundation dimensions.r Footing and foundation delails specifying reinforcement and referenced on plans.. Framing plans for each floor level and roof. All beams, columns, joists, r#ters and trusses specified. Pre-manufactured strudurcs require the engineerc stamp, signature and date.r Framing /connection details, braced wall lines, shear wallschedule, location and hold downs. NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold untilthe required infonnation ie provided. Work may not proceed without the issuance of a permil. The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Road lmpact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having wriften authority from the owner to act as their representative. Building cannot be occupied untila Certificate of Occupancy (CO) is issued. Using the building without a CO willbe considered an illegaloccupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I !erg!,f acknowledge I have read, understand and will abide by the rcquirements of this checklist Owner Print sign,Date:g "/\ ?:<d) RE$DEilNAL EilEFCY EFF|clEilCY a' rt-valDo's rre minimumc' u'facmrs and $Hcc arE maximums. lfo'hcrc insulation is inslallcd in a cavity thar is lcss than the Jrbel or rlcsign thiclnacs of rheinsuhrion.lhc inslallcd f-value of rhc inzulation shrll bc not tess fiar or *-r"fue s[afred in rhc rrble.b. 'Ihe fencstration U-factor colunrn excludcs ekyliglns- The $HGC "otumn appt;cs io'.il gluoa tb*r*riorr.Exception: ID climale zones I through 3, skylith8 shail bc permined to # cxcnaea dom glazcd fcnestration $H6e r-cqtirrmcrrs pmlided tbal ftc sHGcfor mch rkyligtrn doeo ns1 5x.a.6 a.rt. c- "10/l3"meansR'locoulinuousinsulationontheinteriororexieriorofthehonrcorR-l3cavityinsuluionon&cintcriorofthebrscrftntc,sll. "t5/t9" rncanr R-15 continuous insulatior on the inrerior (r ertcriorof thc home o, R-fS *"iE, in J;rh;,h" l";rior of thc btsmcnt $/all AlGrnarivsly,complirnce with "l5/19" shall be R'13 cavity incularionon the intedor of tt u t"ro**r wall plur R-5 couinuous instl|tiolr on drc intefior or exterior df thehomc. I d' R-5 insulation shgll bc nruvidcd undcr the fuli tlab arca of a hearsd sleb in eddition to rle required strb rdge insulotion R-valuc lbr slabs. as indicarcd i, theI rablc- rhe slab edgc iaurlation for hearud rnrr, ,tJrli u. nqrrired to cxrcnd berow rlrc srab.e. Tftcrc art no SHGC rcrluiremcnts in thc Marinc2onr.l" Basctnent wsll ininlation is not rcquirrd in warm-irurnid locrtions as definEd by pigure R3ot,t ad,l.ablc R3Ol.l.g' Altomrtivoly, ingulttion rufficicnl to fitl rtt franrirrg caviry mrl pror.iding not iessilan an R-valuc of R-I9-h' 'lle fust valuc is covitv insulari,n. tl," secsrd "aiue is'ontinirous inJrsrion Th;*f;; ;;;;;;, ..13+5., nrecns R-13 caviry inrulariq ptus R_5continuous inrulatinn, t L Mrsswrljsshatlbcioaccordancswilh'scstionR4o2.2.5-ThesccondR-valrxappliesrvheremorerhmhrlfofttreinsulatimisonthcitrteriorofthoruassw,ll- TABLE R402,I.4 NSULANOilAHD TABTE R4tl:t 1.2 FEilEgf RAnOn RECH,IR EIEI{TS By Cotlpoll$tr cr.rt YE zoilE FEi{HntAnoit t fAcTo#sKl'uoHf {,FACTON GLAED FE}IESTBATOiI $BOCq. cEil-FlG FVALUE vtooD FHAIIEWALL TVAI.UE lr Ss WAII FYALUET FAOOR T}VALI'E BASEilElfi' WALI. FVALUE st-At! SVALUEI I}EPTH cilAtrL SPACE' WALL f;PVALUENR0.25 30 r3 3t4 ll o 0 o 0,rl0 0.25 38 l3 416 t3 0 o IJ J o.32 0.55 a.2s 38 2O or I3+5"8lt3 I9 s/t3'o slrS4 cxccpt Marine o-32 0.55 0.40 49 20or lltSh 8/13 l9 r0 /13 10,2 fi l0/13 5 ard Mnrim 4 030 0.55 NR 49 20 nr l1+5h t3tt7 308 r5lr9 10,2 ft t5n9 NR 49 Xl+Soor 13+l0l r5120 30r l5/r9 10,4 n rs/I9 7 arul 8 NR 49 4115" or l3+l0r tgnt 3Etr r5lt9 to,4 ft r5/r9 NR=11e1i*uir"O- For SI: I foot = 394.9 *n- EQIIVAtEI{T ITFACTOFS' CiUUATE zoltE FEIIESTNAT|OII T'+ACTOR st(Yltclfr I'.FACTffi ccll.rlro GFACTON FNAXE WALL u-Ftcroa ttassrvALL {tFrgroR!Ft-ooF tlFAc?oa 3AgEreilT WATLgfAEron CPAIUL SPACEWALL fr,F cToRI0.50 0.15 o.03J 0.0M 0.t97 0.0a[0.360 0A7720.'m o65 0.030 0.084 0.165 0.064 0.360 0.47730-r12 n(<9.VJt V,UOU I',UYU u.rl47 0-(Bl"0.r364 exccptMarinc 0.32 0.55 0.026 0.060 0.098 0.047 0.05e 0.0655 and Marine 4 0_30 0.55 0.026 0.060 0.0E2 0.033 0.050 0.05560.30 0,55 0-o26 o.or5 o.060 o.o33 0.o50 0.0557and80.30 0.5s 0.0?6 0_045 0.057 0.028 0.0550.050!- Nonfctlsslr{tiun U-fsctorn shAil bc obnaincd hom ttl6g6u'sm€nf , calculation Of an approved source.I b. Mass wallr shsll br: in nccordancc with Section R402.?.5- Where moft $iil halftlrc irsulation is {rn thc intcrior, thc mass wall L{faanrg shall not excced O. | ?in Ctimce 7-onc l, 0.14 in Climae Zone 2, 0. t ? in Climatc Zone 3. 0.0f,? in Climetc ?lne 4 exepr Medrm. O,l{{5 in Climatc Z-ona 5 ud Mcrins 4. md O.O-r?in Climate Zones 6 lhmugh I, c- In wann-humid locatiofis at dcfrncd by F-i3urt R30l.l rnd Table R30l.I, drc bascmenr wall u-thctor shrll nor erceed 0.360- R402.1.f Vapor ret*der. Wall assemblies in the 6aiJd- ing thermal ewelope shall comply with Ore vapor r€tarder requkements of Section R1V2.7 of the lwcrnahonal Resi- dantial Cqdeor Section 14$4.3 rf the Internationat Build- ing Code" a$ applicflble. R402.f.2 Inmtrfiou ond fcne$rration criteria. Thc bailding thermal envelope shall mcet tbe requirements of Table R402.1.2, based or rhe dimate eonr. spccified in Chapter -3- Rl(}2.f3 f,-valuc computstion. trnsulation material used in laycrs, such as framing covity insulation or continuous insulation, shall bc summed lo compute the corrcsponding componcnt R-value. The manufacturer's settl€d R-valuc $hall be used for blowrpin insulation. Computed rt-values shdl not insludc an lt-valuo for ottror buildihg matcriuls or air films. Where insulated siding is used for rhe prqrose of conplying with tho coRtitruous insulation requirembnr of Tabh R4,02.1.2, Orc mamfacrurer's labclcd B-value for the insulatcd siding shall h reduced by R4.6. 8402.1.4 U.factor alternntivc. An assembly wilh a U-fac- tor equal to or lec.$ than thar sp€cified in Table Rrl02.l.4 shall b€ an aksrnative to the ft-vahc in Tuble R4O .l .2. R€O cq,lrrr'D&,,,..' A,.nrc,.TsrEsr*vr'.^*-rr,*.*ffi,, **X*f:-ffi[9.,""#sE'vtrto* coDEt Lr@it.*nrerhrrrc. Noridhdn rodudiorordr*ibrroreudnd*d sr{hwnr}..(qrirrudB'.seF@iled.{Nr,;Ilff;ilflT;;.#,JiXX1l.ff:lH:LXrji. Garfteld County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81501 (9701 94s-82L2 www.ga rf ield cou ntvco.gov BUITDING PERMIT FTE ESTIMATE WORKSHEET Applicant: Miller's Project Address: L422 High Aspen Drive Subdivsion: Phone: Lot:Block: Ivpe of Space Square Feet Valuation Finished Living Space (N/A for Manufactured Homes)44L6 s101.4s Unfinished Basement s32.00 Crawl Space s24.00 GaraRe (Attached)1.1.48 s32.oo Garage (Detached)S4o.oo Covered Patio/Deck 144 s24.oo Uncovered Patio/Deck 256 S18.oo Misc: Remodeled area 520.2s Misc so.oo i:' Ir.,:r '';.,.t|1,.,t,a.t '::l ..: i,a: a.:: .i.l .t:.4. l: tt.tt; i/.. . Manufactured Home Set-Up Fee Sinsle Level (5400)so.o0 Multi-Level (S600)So.oo '..'\, i .i'it, Septic {OWTS}Fee New lnstallation (5600) Septic - Maior Repair (New System & STA) (SOOOI Septic - Minor Repair (Tank Only) (5200) Alteration (S200) Vault & Haul (S7s)so.oo 52,076.46Plan Review Fee s3,r.94.ssBuilding Permit Fee Manufactured Home Set-Up Fee Septic Fee (OWTS) s2,703.00Other (Ex: Road lmpact Fee) ***All fees are estimates until final plan review is completed*** Gerfield Coan$t BUILDING DEPARTMENT 108 Eighth Street, Suite 401, Glenwood Springs, CO 81601 Tel: (970) 945-8212 PLAN R EVIE WCHE c KLIST EtRE-og-a6- ///,'llerPermit No: Building lssues Q?-ru wk v* (r/' Planning/Zoning lssues $J.ft-35 ft. Stream Setbacks l.)l: Ftood ptain lol t3 Property Line setbac-@ E)Engineered FoundatLo:n Permit Surveyed Site PIan eE77-0?4s-gtb3 Septic Permlt and Setbacks Grade/ TopographY 3O% Attach. Residential Plan Revievu List Subdivision Plat Notes Fire Department Review Valuation Determination/ Fees Red Line Plans/ StamPs/ Sticker Attach Conditions v/ / 76s Building Height Zoning Sign-Off Poad lmpact Fees Grade/ TopograPhY 40% Planning lssues Subdivision Plat pla.|- Application Signed Energy Compliance Path/Plan Received Plan Reviewer to Sign APPlication Parcel/ Schedule No 75 lb 40# snowload Letter - Manuf. Homes v'- soils Report Descri otion & Su marv: AfF,u/tfr, zR //u/6 D$xff t4?//6FR t4n- Nl, Auybq zt6VZFZotfztS 3r a,crsg fl)-) vanyt bf h iltv I 0t whilebirtkr ir.y Ai+e\-/creeLT I + 0r v.e' tl "f#O h**gbaA bo,,wdary = t't/ A$' / of lZ