Loading...
HomeMy WebLinkAboutApplicationGarfield i'ii 1.1,11.'i ii i,i Community DevelopmentDepartinent ; i 108 8th Street, Suite 401 Glenwood Springs, CO 81501 (97Ols4s-82t2 www.sarfield-counW.com Manufactured Home lnstaller: N/A Phone: ( ) Describe Work:ADDITION OF A ROOF TO COVER AN EXISTING TERRACE Mailing Address Email Address: BUILDING PERMIT APPLICATION WPEOFCOT{STRUCNON Commercial/Multi-Family Demolition Manufactured Home or Tiny Home (Single or Multi-Level) I Residential {SF, Duplex or Townhome)COVERED PATIO ADDITIC Reroof Accessory Dwellins Unit (ADU) - MAXIMUM SIZE OF 1,200 SQUARE FEET INVOTVEDPANNES / STEVE & SHAY PENTON 26 SWEET GRASS DRIVE 1958Phone: Email Address. 25PENTON@GMAIL.COM Property Owner: Mailing Address: TBD Phone: ( )Contractor: Mailing Address: Email Address: Architect: BRAD JORDAN/JORDAN ARCH|TECTUR|pnone, (970 )6186690 PO BOX 1031, GLENWOOD SPRINGS, CO 81602 Emait Address. BRADJORDANARCH ITECT@GMAI L-COM Mailing Address Emait Address. SrEVE@MOU NTAI NTOWN CG. COM 107766Phone:Engineer:STEVE EDMISTON/MTCG Mailing Address:PO BOX 1577, BASALT, CO 81621 t/ t robAddress:26 SWEET GRASS DRIVE Assessor's parcet Numb er 239320404118 sub.ASPEN GLEN Owne/s Valuation of Work:7200.00 Sq. Ft. of Building:EXISTING Height: Lot D18A ebck 1 Propefi Size (Sq. Ft. or Acres):.787 AC EXISTING f of Ftoors.EXlSTlNG Class of Work: Garage ched Remodel/Alteration Detached PROJECT DETAITS CONNNUED i Septic: Type of Heat:ral Gas Propane Community Electric Other l Driveway Permit: pt Permit #: AuthoriW. This application for a Building Permit must be signed by the Owner of the propefi, described above, or an authorizod agont- lt thp sisnatrrre helow ic not thet nf the (.)wnar a (Fn2ra+e lettpr nf rr rthnritrr <iorrrrl lrrr the Owner, must be provided with this Application. legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for purposes of inspections by the Building Division. Other Permits. Mu Itiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit, (3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access or a State Wastewater Discharge Permit. Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days affler commencement. CERNFrcANON I hereby certify that I have read this Application and that the information contained above is true and correct. I understand that the Building Division accepts the Application, along with the plans and specifications and other data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and applicablc land use regulations (County Regulation(s)). All County developnrent requirirrg a pernrit, except for residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building Permit may be suspcnded or revoked, upon notice from the County, if the location, construction or use of the structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law. I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I frrrther acknowledge that thp issuanrp of the Building Permit does not prevent the Building Official from: (1) requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction or use of the structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this Application, including submittals, and inspections of the work by the Building Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or builder. I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have provided the required information which is correct and accurate to the best of my knowledge. Steven Penton 3131t202s Property Owner Sign Date oFFlctAL usE oilLY-C -l Special Conditions: 6e? a,LLa riz I cANb / TONS Adilrsted Valrration: 6-/^ 2!O.oa "qL:"f;r"Permit Fee:153,^5 Manu. Home Fee: '-- Misc. Fees: Uo53z,8u Fees Paid:qq vt Balance Due: z | 63 ^2" BP No: A-I,AE -qns OWTS No: t#f8.6.occ Group: IRC ton*lPa -'l5r i'n I v BUTTDTNG / '.-ANNTNG DrvrsroN , ( L! ;r44x- 'l ^ A-Zi .:-. ^ lJrtsilcq ApPruvilt uate ENERGY COMPLIANCE SHEET REQUIREMENTS: Effective June 30, 2023Please provide details showing how building complies / meets Garfield County's adopted 2018|ECC and Climate Zone 5, Depict and show outline the structure's building thermal envelope. Outline should clearly show portions of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining unconditioned outside this envelope) Energy Compliance Plan should further include: Chosen Energy Compliance Patho Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value and U-Values to comply with IRC Table R402.1.2 r U-Factor Alternative: Provide a ResCheck Report. Total U-Factor Alternative: Provide software generated submittal design reports and inspection checklist for any RESNET ERI index or other performance path designs Air sealing details around openings, pipes, penetrations, joints Fenestration U-factors Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel types, locations Energy efficient lighting specifications - 90% to be high-efficacy (LED complies) Manual J Report required for new building structures and new equipment installations. STRUGTURAL PLANS: Please provide the following information on the structural plans. . SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific soils investigation report or if Structural plans make a specific reference to a soils report, then a copy of the soils report is required to submit a building permit application.. Design specifications to include roof and deck snow load, wind and seismic design and frost depth.r Foundation plan showing complete footing and foundation dimensions.. Footing and foundation details specifiTing reinforcement and referenced on plans. . Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses specified. Pre-manufactured structures require the engineers stamp, signature and date.. Framing /connection details, braced wall lines, shear wall schedule, location and hold downs. NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf determined by the Building Official that additional information is necessary to review the application and/or plans for compliance, the application may be placed on hold untilthe required information is provided. Work may not proceed without the issuance of a permit. The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as well as any Road lmpact fees will be collected when the permit is issued. The permit application must be signed by the owner or by person having written authority from the owner to act as their representative. Building cannot be occupied untila Certificate of Occupancy (CO) is issued. Using the building without a CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO inspection requirements will be attached to your approved field set of plans.) I hereby acknowledge I have read, understand and will abide by the requirements of this checklist. Owner Print: Steven Penton Sign Date:3131t2025 too743404 RESIDENTIAL ENERGY EFFICFNEY R402.1.1 Vapor retarder. Wall assemblies tn the build- ing thermal envelope shall comply with the vapor retarder requirements of Section R.7O2.7 of the International Resi- dential Code or Section 1404.3 of the International Build- ing Code, as applicable. R402.1.2 Insulation and fenestration criteria. The building thernwl envelupe shall urcct [rc requiremelts of 'l'able R402.1.2, based on the climate zore specified in Chapter 3. R402.f3 R-value computation. Insulation material used in layers, such as framing cavity insulatioz or continuous insulation, shall be summed to compute the corresponding component R-value. The manufacturer's settled R-value shall be used for blown-in insulation. Computed R-values shall not include an R-value for other building materials or air filmo. Whoro inoulatod oiding io ucsd for tho purposc of complying with the continuous insulation requirements of'lable R40?.1.2, the manut'acturor's labolsd R valuo for the irrsulated siding shall be retluced by R-0.6. R402.1.4 U-factor alternative. An assembly with a U-fac- tor equal to or less than that specified in Table R4O2.I.4 shall be an alternative to theR-value in Table M02.1.2. 2018 INTERNATIONAL ENERGY CONSERVATION CODE@ CoPFighte20rTlCC. ALLRICmSRESERWD-Accssedhytohnplano(iplano@erbondaleco.net),(ToMofca.bondite)OrderNumb€rrtoo743s4onAug13,2oreo7r3AM(PDT)pu*uantto LiensAgrem€ntfrthICC. Notur&srr€pmdudionordistsibutionauthodz€d. Singtewronlrcopyhgildreorkingprohibiled.ANYUNAUTHORIADWRODUCfIONORDISTRIBUTION iS A !'IOiAflON OF THS TEDEML COPYruGHT ACT ND ffiE LICENSE ,\GWENT, AND SUBJECT TO CML ND CruMNI PNALTTES THEMWDER. TABLE R4O2.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTe NR = Not Required. For SI: 1 foot = 304.8 mm. a. R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of the insulation. the installed R-value of the insulation shall be not less than the R-valne specified in the table. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: In Climate Zones I through 3, skylights shall be permitted to be excluded from glazed fenestration SHGC requirements provided that the SHGC for such skylights does not exceed 0-30- c. "10/l3"meansR-l0continuousinsulationontheinteriororexteriorofthehomeorR-l3cavityinsulationontheinteriorofthebasementwall. "1 5/1 9" means R-I 5 continuous insulation on the interior or exterior of the home or R-I 9 cavity insulation at the interior of the basement wall. Altematively, compliance with "15/19" shall be R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of lhe home. d. R-5 insulation shall be provided under the ftrll slab area of a heated slab in addition to the rcqutcd slab edge insulation rR-value for slabs. as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slab. e. There are no SHGC requirements in the MarineZnne. f. Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1. g. Alternatively, insulation sufficient to fill the framing cavity and providing not less than an R-value ofR-19. h. The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "13+5" means R-13 cavity insulation plus R--5 continuous insulation. i. MasswallsshallbeinaccordancewithSoctionM02.2.5.ThesecondR-valueapplieswheremorethanhalfoftheinsulationisontheinteriorofthemasswall. TABLE R402.1.4 EOUIVALENT U.FACTORS" CLIMATE ZONE FENESTRATION U-FACTOR SKYUGHT U.FACTOR CEILING UfACTOR FRAME WALL U+ACTOR IIASS WALL U.FACTORb FLOOR U.FACTOR BASEMENT WALL UfACTOR CRAWL SPACEWALL U+ACTOR I 0.50 0.75 0.035 0.084 o.197 0.064 0.360 0.477 2 0.40 0.65 0.030 0.084 0.165 0.064 0.360 o.477 J 0.32 0.55 0.030 0.060 0.098 0.047 0.091"0.136 4 exeelt Manne 0.32 0_55 0.025 0.050 n non no'1 n n<o n nK< 5 and Marine 4 0.30 0.55 0.026 0.060 0.082 0.033 0.050 0.055 6 0.30 0.55 o.026 0.045 0.060 0.033 0.050 0.055 7and8 0.30 0.s5 o.026 0.045 0-057 0.028 0.050 0.055 a. Nonfenestration U-factors shall be obtained trom measurement, calculation or an approved source- I b- Mass walls shall be in accordance with SectionFr4$2,2,5. Where more than half the insulation is on rhe interior, the mass wall {/-factors shall not exceed 0.17 in Climate Zone l, 0.14 in ClimateZone 2,O.12 in ClimateZone 3, 0.087 in Climate Zone 4 except Marine, 0.065 in Climate Zone 5 and Marine 4, and 0.057 in Climate Zones 6 through 8. c. In warm-humid locations as dcfined by Figure R30 1. I and Table R301.1, the basement wall U-factor shall not exceed 0.360. CLIMATE ZONE FENESTRATION {IFACTORb SKYLIGHTb U+ACTOR GLAZED FENESTRATION sHGCb'" CEILING FVALUE wooD FRAMEWALL RVALUE ITASS WALL P-VALUEI FLOOR BVALUE BASEi'EilTC WALL RVALUE SLABd RVALUE & DEPTH GIIAWL SPACP WALL BVALUE I NR 0.75 0.25 30 l3 3t4 I3 0 0 0 2 0.40 0.65 0.25 3E t3 416 l3 0 o 0 3 0.32 0.55 o.25 38 20 or 13+5"E/l 3 l9 slt3'0 slt3 4 except Marine 0.32 0.55 0.40 49 20 or l3+5h 8/l 3 t9 t0 lt3 10,2ft 10/13 5 and Marine 4 0-30 0.55 NR 49 .)ll ^. I L(h 12111 ?al8 I </to 1.} t fi t<r10 6 0.30 0.55 NR 49 20+5'or 13+10"15l2o 30r t5lr9 r0,4lf t5l19 7and8 0.30 0.55 NR 49 20+5" or 13+10'19t21 3gs r]it9 10, 4 ft r5/r9 INTERNATI c0DE couNcrr R-30 Ger$eld Coan$t BUILDING DEPARTMENT 708 Eiqhth Street, Suite 401, 6lenwood Springs, CO 81601 Tel: (970) 945-8212 PLAN REVIEW CHECKLI ST Permit No: A&-O(-ZO-?fl A Pla n ni ng lToning lssuesssues Fou.ndalio.n Driveway Permit Surveyed Site Plan Septic Permit and Setbac'rs Grade/ Topography 30% Attach Residential Plan Review List Application Signed Energy Complia nce Path/Plan Received Plan Reviewer to Sign APPlication Parcel/ Schedule No. 40# Snowload Letter - Manuf. Homes Soils Report B.E, Flood Plain o E -'ruilding Height Zoning Sign-Off /c,^del Topography 40% Planning lssues Subdivision Plat N 4 Road rmpact F".0 o w)^)n-1.S.) m ,) Description & Summarv Minop ov*/^oor I e{UeA ro+ ,?to,u o^l 1 ',1 antahrm *vzoo.oD