Loading...
HomeMy WebLinkAboutGeotech Investigationtants lncn GsotGchnlel / Envlronmentel Engincerlng. ltlat€ridt Tcttlng June 19,2018 Deb Fiscus Garfield County Landfill 0075 County Road 246A Rifle, Colorado 81650 Job Number:02-5136 Subject: Preliminary Geotechnical Investigation and Geologi c Hazard Evaluation, West Parcel Development, Garfield County Landfill (GCLF), Rifle, Colorado Dear Ms. Fiscus: An approximate2}-acre parcel located at the west side of GCLF is owned by Garfield County and intended for future landfill use as the facility develops. An open and vacant area at the north side ofthe landfill access road andjust before the scale house encompasses a portion ofthe 20- acres. For discussion purposes this will be referenced as the West Parcel Development O[PD). The general vicinity is shown on Figwe 1 and the WPD area is shown on Figure 2. Backsround Based upon Garfield County's directive during approximately 2009, NWCC developed conceptual designs to construct an engineered and robust polyethylene doublelined cell including leak detection at the WPD in response to Energy and Production (E&P) Industry pressure to dispose highly contaminated E&P wastes at GCLF. The intent was to respond to industry waste disposal needs while limiting potential environmental release liabilities through consfruction of a waste disposal cell adequately designed to contain these highly contaminated materials. A Sfiategic Solid Waste Management Plan (SSWMP) (NWCC/AECOM, May 2014) was developed and implemented by the Garfield Board of County Commissioners during 2014 to systematically develop the landfill into a self-sustaining enterprise system through thoughtful and careful planning. The E&P waste cell was recommended with the addition of a solidification basin. However, shortly after implementation of the SSWMP, a down-turn in the E&P industry occured, E&P waste receipts declined, and continues to date. Therefore, the county determined to suspend discussions regarding this facility. To help expedite landfill planning and help determine how the WPD might best be used, GCLF requested that NWCC, Inc. (NWCC) conduct a preliminary geotechnical evaluation of the WPD. Numerous options exist and use of the parcel should be encompassed in overall landfill development, planning, and revision of the SSWMP. This geotechnical phase is a first step and additional evaluation (e.g. groundwater characterization) may be required depending on what the final intended use of the WPD will be. NWCC conducted field activities on September 28, 20I'l that included obtaining data from cursory observations, excavation and logging of five test pits, soil sampling, and subsequent analysis. GCLF provided excavation services. Soil samples were fransported to the NWCC (970) 879-7888. Fax (970) 879-7891 2580 Copper Ridge Drive . Steamboat Springs, CO 80487 Geotechnical Investigation - West Parcel Development June 19,2018 Geotechnical Laboratory located in Steamboat Springs, Colorado for soil classification and materials properties testing. Field activities and findings are surnmarized below. Site Conditions The WPD was undeveloped and vacant during site activities and appears to be situated within a previous burn area. The vegetation consists of sage brush, sparse weeds, and grasses and the topography is variable and generally slopes moderately down to the south-southwest. West Sherrard Creek intermittently flows along the east side of the parcel and two intermittent drainages are located north to south, one through the approximate middle and one along the west side of the WPD. Surface water was not observed in these intermittent drainages during site activities. Natwal gas pipelines are located along the east and south perimeters of the WPD. Ge olo gic H az ard C onditi ons Landslide or signs of slope instability were not observed in the WPD and cut slopes or excavations are anticipated to be relatively stable. NWCC concurs with the Land Transfer Audit (Land Transfer Audit, West Garfield County Landfill, TerraMatrix, May 1995) findings that, "Steep slopes on the north edge ofthe property pose a geologic hazard for the northern portions of the property. Hazards include rock fall and mass movement. A majority of the site is free from geologichazards." Based on NWCC's site observations, terrain at the WPD is relatively flat while the overall terrain gently slopes to the south and southwest. The immediate land surface at the north side of the WPD is further from the cliff base and does not rise nearly as high or as steeply as along the north and northwest sides of the main landfill areas. The slope appears stable as the topography is relatively flat and the area appears well drained. Even though clays are present on-site, the swell potential appears relatively low and should not have an adverse impact on proposed structures, if properly designed and constructed. Overall, geologic hazards at the WPD appear minimal and less likely than in the main landfill area along the cliff base. Subsurface Conditions To investigate subsurface conditions, five test pit locations were proposed. Prior to test pit excavation, a surveyor under confract with GCLF located the proposed test pits. GCLF excavated the five test pits using a Volvo EC300 EL trackhoe. Excavations continued unfil the limits of the trackhoe were reached or refusal. The approximate test pit locations are shown in Figure 2. Test pit locations were not surveyed. The subsurface conditions encountered were variable and generally consisted of a relatively thin layer ofnatural topsoil and organic materials overlying interbedded clays, gravels and sands to the maximum depth investigated. Test Pits 1 through 3 were excavated to 21 feet below the existing ground surface (bgs), which was the maximum reach for the trackhoe. Practical rig refusal with the tackhoe on boulders was encountered in Test Pits 4 and 5 at depths of 16 and 17 feet bgs, respectively. Graphic logs of the exploratory test pits, including the associated legend andnotes, are provided in Figures 3 and4. A layer of natural topsoil and organic material was encountered at ground surface in all the test pits and ranged from 2 to 10 inches in thickness. Interbedded clays, gravels and sands with numerous cobbles and boulders were encountered beneath the topsoil and organic materials in all of the test pits and extended to the maximum depth excavated in each test pit. The interbedded clays, gravels and sands were fine to coarse grained with numerous cobbles and boulders, low plastic, medium dense to stiff, dry to slightly moist, and brown in color. Samples of the soils ITWCC,Inc. Geotechnical Investigation - West Parcel Development Garfield County Landfill, Garfield County, Colorado May29,2018 obtained from the test pits at various depths classified as CL to CL-GC to GC to CL-SC soils in accordance with the Unified Soil Classification System. Groundwater was not encountered in the test pits during the field investigation; however, groundwater levels in monitoring wells at the adjacent landfill increase and decrease with seasonal changes. Shallow groundwater is typically perched atop impervious bedrock and believed to be recharged through precipitation and seasonal runoff. Bedrock was not encountered in any ofthe test pits. Soil Sample Collection A total of 10 soil samples were collected including, one sample at Test Pit 1 from 20 to 2I feet bgs, three at Test Pit 2 from 5 to 6, Il to 12, and 19 to 20 feet bgs, three at Test Pit 3 from 2 to 3, 10 to 11, and 17 to 18 feet bgs, one at Test Pit 4 from 7 to 8 feet bgs, and two at Test Pit 5 from 1 to 2 and 9 to 10 feet bgs. For testing puq)oses, portions of each sample were composited at the laboratory into sample 1P*. Laboratorv Results Samples obtained from the test pits were examined and classified in the laboratory by the project engineer and principal engineer, prior to conducting the testing. Laboratory testing included natural moisture content, grain size analysis, liquid and plasfic limits, standard Proctor, unconfined compressive strength and falling head permeability testing. Laboratory testing was conducted in general accordance with applicable ASTM/AASHTO specifications. Results of the labomtory tests are summarizedin Table 1. Based upon testing of the 10 collected samples, in-situ moisture contents ranged from 5.2 to 8.0%; liquid limits ranged from 23 to 29o/o and plasticity indices from 9 to l4%. Composite sample lP was screened on the /+-inch sieve and a standard Proctor test was conducted on the materials passing the 314 -inch sieve in accordance with ASTM D 698. The standard Proctor Test provides maximum remolded dry density and optimum moisture content data to assess material conditions for compaction and construction pwposes. Sample lP classified as a CL-SC soil (gravelly sand and clay), the optimum moisture content is I3.5% and the maximum remolded dry density was 117.8%. The Proctor test results are shown on Figure 5 and summuizedin Table 1. Relatively undisturbed, hand drive samples were taken as the Proctor Test was completed. Falling head permeability and unconfined compressive sfrength tests were conducted on the remolded samples. Based upon laboratory results, the remolded permeability of the sample compacted to 98.7 percent of the maximum Proctor denstty and 1.3 % below the optimum moistwe content was 6.82 x l0-7 centimeters per second (cm/sec) and a sample compacted to 95.5% of the maximum Proctor density and 3.1 %o above the optimum moisture content was 2,400 pounds per square foot (psf). Results of the falling head permeability tests are shown in Table2. Preliminarv Geotechnical Recommendations The intent of conducting the limited geotechnical evaluation was to provide cursory information for planning purposes. Since the fuhre use of the WPD is unknown, this investigation is considered a first step to help evaluate what other investigations, if any, may be required depending on proposed uses of the parcel. NWCC understands that a scale house move to the landfill access road in this area is planned. This report, augmented by geotechnical engineer field observations, may be used to design improvements associated with the planned scale house move (e.g. scale house foundation, road base, and parking area base). NWCC, Inc. Geotechnical Investigation - West Parcel Development Iune 19,2018 The parcel may be considered adequate for numerous uses (e.9. septage treatment facility and/ or impoundments, recycle area, borrow source, solar panel farm). However, to achieve optimal use of the parcel, carefrrl and thoughtful planning is required. Preliminary Foundation Recommendations NWCC believes a feasible foundation system for the proposed buildings and./or stuctures at the site will consist of spread footings or reinforced mats placed on the natwal clays, gravels and sands or on properly compacted structural backfill materials. NWCC suggests that the recommendations outlined below be followed in the preliminary design of the buildings and sfructure foundations. 1) NWCC recommends the footings and./or mats be placed on the clays, sands and gravels or properly compacted structural backfill materials be designed using an allowable soil bearing pressure of 3,000 psf. Based on the assumed swell potential of the on-site clays, NWCC recommends the footings and/or mats also be designed using a minimum deadload pressure of 500 psf. 2) NWCC recommends a Site Class C designation be used in structural design calculations in accordance with Table 20.3-1 in Chapter 20 of ASCE 7-10. 3) Lateral resistance of foundations placed on the natural soils or properly compacted fill materials will be developed as sliding resistance of the footing on the foundation materials. Sliding friction at the bottom of the footings or mats can be taken as 0.40 times the vertical dead load. Passive pressure against the sides of the footings or mats can be calculated using an equivalent fluid unit weight of 250 pcf. Compacted fill placed against the sides of the footings or mats to resist lateral loads should be compacted to at least 100% of the maximum standard Proctor density determined in accordance with ASTM D698. 4) Footings and mats should be placed well enough below final backfill grades to protect them from frost heave. Thirty-six (36) inches is recognized by the local building authority. 5) Based on experience, NWCC estimates total settlement for footings and mats designed and consfiucted as discussed in this section will be approximately I inch. Care should be taken when excavating the foundations to avoid disturbing the supporting materials. Disturbing the bearing materials may increase settlements. Preliminary Site Grading Recornmendations NWCC assumes site grading at the site could include cut and fills, ranging from 5 to 30 feet in depth, depending on the proposed development plan. The following recommendations should be observed for preliminary site grading design and construction. l) Temporary cuts for foundation construction should meet OSHA safety standards for trenching and temporary excavations. Permanent, unretained cuts should not exceed a 2(H):1(V) configuration. Permanent cut slopes should be limited to 30 feet in height or less unless stable bedrock is encountered. The risk of slope instability will be significantly increased if groundwater seepage is encountered in the cuts. NWCC should be notified immediately to evaluate the site if seepage is encountered or deeper cuts are planned. Additional investigations and/or stabilization measures may be wa:ranted at that time. 2) Contractor must provide a consffuction sequencing plan for excavation, wall construction and bracing and backfilling for the steeper and more sensitive portions of the site prior to starting the excavations or construction. IYWCC,Inc. Geotechnical Investigation - West Parcel Development Garfield County Landfill, Garfield County, Colorado May29,2018 3) Fills up to 30 feet in height can be constructed to a 2(H):1(V) or flatter configuration. Fill areas should be prepared by stripping topsoil and organics, scarification and compaction of exposed subgrade to at least 95%o of the maximum standard Proctor density and within 2% of optimum moisture content as determined by ASTM D698. Fills should be benched/keyed into natural hillsides after the topsoil and organic materials have been stipped using minimum 6-foot wide benches. Fill materials may consist of the on-site soils (exclusive of topsoil, organics or silts) and should be uniformly placed and compacted in 6 to 8 inch loose lifts to the minimum density value and moisture content range indicated above. 4) Where unstable fill surfaces cannot be stabilized by scarification and recompaction, additional stabilization measures will likely be required. These measures may include additional subexcavation and bacldrll with imported granular materials and/or placement of stabilization fabric (Mirafi 500X or equivalent) or geogrid products. Stabilization requirements are likely to be variable based on subsoils, groundwater levels and surface runoff conditions at the time of construction, and should be evaluated by NWCC at the time of construction. 5) Surface drainage features should be provided around all permanent cuts and fills and steep natural slopes to direct surface runoff away from these areas. Cuts, fills and other stripped areas should be protected against erosion by revegetation or other methods. Areas of concentrated drainage should be avoided and may require the use of riprap for erosion contol. 6) A registered professional engineer experienced in site plan preparation in this arid to semi-arid geographic area is recommended for site grading and drainage plan preparation. 7) Subgrade preparation and placement of materials should be observed and tested by NWCC in the field and laboratory for compliance with the contract documents. Conclusions Based on NWCC's site observations, the results of the field and laboratory investigations, and experience with other projects at the GCLF, NWCC believes that the soil properties are acceptable for various construction purposes provided the structures are properly designed and constructed. Hazardous geologic conditions at the site that would render the proposed WPD unfeasible were not observed. Limitations This report has been prepared in accordance with generally accepted geotechnical engineering practices in this area. The conclusions and preliminary recommendations submitted in this report are based upon the data obtained from the exploratory test pits advanced at the approximate locations shown on the site plan, the results of the laboratory investigation and NWCC's experience with similar projects in this area. The test pits were widely spaced to evaluate the subsurface conditions in the vicinity of the WPD. We believe that this information gives a high degree of reliability for anticipating the conditions across the site. However, the recommendations contained in this report are professional opinions and cannot control nature, nor can they assure the subsoil and groundwater conditions beneath or adjacent to those observed. Professional judgments based on the subsurface conditions encountered are presented in this report. They are based partly on evaluation of technical information gathered, partly on our observations made during the field investigation, partly on our assumptions regarding the proposed construction, and partly on our experience with other projects having similar subsurface conditions. NWCC does not warranty or guarantee the performance of the project in any respect; NWCC, Inc. Geotechnical Investigation - West Parcel Development June 19,2018 only that our engineering work and judgrnent rendered meet the standard of care in our profession at the time it was rendered. This report is based on the investigation at the described site and on the assumed construction as stated herein. If either of these conditions is changed, the results would also most likely ohange. Therefore, NWCC strongly recommends that our firm be contacted prior to finalizing the construction plans so that we can verify that our recommendations are being properly incorporated into the construction plans. Man-made or nafural changes in the conditions of a property can also occur over a period of time. In addition, changes in requirements due to state of the art knowledge andlor legislation do from time to time occur. As a result, the findings of this report may become invalid due to these changes. Therefore, this report is subject to review and not considered valid after aperiod of 3 years or if conditions as stated above are altered, If you have any questions regarding this report or if we may be of further service, please do not hesitate to contact us. Sincerely, NWCC,Inc. Erika K, Hill, E,I.T. Project Engineer ,. Reviewed by Brian Principal Engineer Z:Uobs\02"5136 Gorffold County Landfill\Engineering\ West Parcel Dovolopmeht\GcLF WpG Preliminary Geo Inv snd Oeohlzsrd Evnluation NWCC, Inc. Figures 1 ioii CO-OIADOito a.i J:ritlei. rcsco5.000 w t GSS: rn7:ii.ooar !r 10sr8!.00Q'f/rntrsl oco rli N/G5S.::.00( rr l- I :f;.:.::. _o?t t.:. :.r-i C.i-:r.,. r-........_+r. 1. _ GARFIELD COUNTY LANDFILL 1 .O FI frLAAZ H<6 oa.aao AAp= (Jf q i>Hrzl tz7 ZvuF ffi $, m o r o=oo o o c=oo z > Idcm o tr Irze E = fi=l d F ! rda9 r i dlri = q > r*t E E fi EE' - ol's =F o-iFz=ga I oo c oo =tsH49>0a-f,d662@ oF69PTH;toogn trg 6z 6I czo u iEgFet=c*FcHE E I I Es65 *sfigH R d E F E3 ESEEx 5 d e t= Fii 'Hf; * 5 z MFH ilt-r: g 1l IFIH H c ou ofi 5 mz I ozIo - -5 a q( s(/ .3 ( "3 a fc -)$;ET E $ o f s++- "J"e"'q dI s T .\$ t ltt ?t.i ''Ll r H e 1 ,6 t i* ) /'t E a I E %l ,t I I\ ) q-g / c / tsd ss T ! !e r t T I Tt tI g I / I 3o ( f;-2--F t N o Es* FE6E385* ErEhFYT'OHZItJ4>1 ?H Fo C) 'l>ld 4a5'lz,r <FltrFd Hffi ) &i i ! d 3 \ I s R d e i i i .ri ! I + R Teet Pif. I Test Pit 2 Test Pit 3 Depth (ft) 0 0 5 5 10 10 15 15 20 20 25 25 T,EGEND:NOTES: 1) Test pits vere excavated on September 28,' 2OL7 rith a Volvo EC300 EL trackhoe provided by client.a TOPSOI AND ORGANICS w CIAYS, GRAVELS AND SANDS - Interbedded, fine to coarse grained with numerous cobbles and boulderg, lor plastic, medium dense to stiff, dry to slightly moist and brorn. 2l Test pit locations rere determined by' instrument survey provided by client. 3) 4) The elevations of the test pits were not measured and the logs are drawnto t,he depths investigated. I Large Disturbed Bag Sample.The lines betveen materials shorn on the test pit logs represent the approximate boundaries betveen material types and transitions may be gradual. Title:LOG, LEGEND AND NOTES Dete: 5/3o/2018 1970)87sm. Fs (070)EB7&1 2S &ptd RBF Dil. Sbmhd Stlns, trd &87 Job Name: 'ITest Parcel Development Job No. 02-5136 Ioca$oa:Garfield County, Colorado It8ure B Test Pit 4 Test Pit 5 Depth (ft) 0 0 5 5 10 10 15 15 20 20 25 25 I,EGEND:NOTES: a TOPSOI AND ORGANICS.1)Test pits lrere excavated on September 28, 2017 rith a Volvo EC300 EL trackhoe provided by client. CLAYS, GRAVELS AND SANDS - Interbedded, fine to coarse-grained, ritb numeroua cobbles and boulders, low plastic, medium dense to stiff, dry to slightly moist and brown. 2)Teet pit locations were determined by instrument survey provided by client. 3)The elevations of the test pits vere not meaeured and the logs are drarnto the depths investigated. I I Large Disturbed Bag Sample. 4)The lines betreen materials shorn on the test pit logs represent the approrimate boundarieg betreen naterial tyles and transitions may be gradual.Indicates depth of practical rig refusal on boulder. Tltle:LOG, LEGEND AND NOTES Dete: 5/3O/2Ot8 (970)87$7E&. Fd(070)87e7&1 2S OpF Rtsgs 0to3 sbnbd sginF, mEdo u87 Job Nane: 'IYest Parcel Development Job No. 02-5136 Iocatlon: Garfield County Landfill, Garfield County, Colorado Fkure A.} (Jlo otN"rr l9lo lo "H l:illo HIF"r l?Nlo \lo 5oooo Dry Density - PCF N)oOoo(oo@O o (Jl o 3 9.o octlo(Jt o Ts N)o N)(Jr (r)o LI ,nLN 1,il t{ lrn il W I,rt IA n ( ITI,t 1 W tl Yt h il N t l1l ffi t 1)AI Il I ]l.Ll T\I ! n A v{ t 4 n I x 't$l.t fiT NV IlYt WI t{ v I I o Ezo I €oo ll 0)a() q_ clo 9.oE 3oa Ioq) =s9_o- oocf t-!) =o- = !noo-{on{ma,{-m U,c o I I @D g o ooql 3io oo 3!o c2. o CN 0) 3E 6- oI oooo:.It =to3 oa o) !P- @q))o- olo- a 0) I a)o 6oloo- o CD 5 = @ o o o!l 3oozo 1' =o x. 3tr 3 oeoo =o { bo ro C) oItF =9.o c o oo o:!? 9^'(,l s ! ooo CLtr o @+ g o)(O @ trltc CL tr i,l N)(Jl s ! ooEi c. 3 CLox os E, AI o N)(o No o o o, g \t s an AI J* 5o s 9, Fo ot ING'o 5o) s oC'z 9 oNt(,l (r) o) 'nq tr d gr Tables NWCC, Inc. TABTE 1 SUMMARY OF LABORATORY TEST RESULTS UNIFIED soIL CI,ASS. 1 zo-21 6.0 25 t2 39 26 35 Sandy Clay and Gravel GC-CL z 5-6 8.0 24 11 30 30 40 Sandy Gravelly CL z II-L2 7.6 24 11 28 27 45 Sandy Gravelly Clay CL 2 19-20 7.1 26 13 28 30 42 Gravelly Sandy Clay CL 3 2-3 7.O 25 I 39 29 32 Sandy Clayey Gravel GC-GM 3 10-11 7.2 z5 11 40 27 33 Sandy Clayey Gravel GC 3 t7-18 7.1 2?L4 36 26 38 Sandy Clay and Gravel CL-GC 4 7-8 5.2 25 13 42 23 35 Sandy Clay and Gravel GC-CL 5 1-2 5.7 29 T4 36 22 42 Sandy Gravel CL-GCand. b 9-10 5.4 23 10 44 30 z6 Clayey Sandy Gravel GC 1P 13.5r 117.8*25 10 l?".40 43 3400**Gravelly Sand aud Clay CL-SC SOIL or BEDROCK DESCRIPTION UNCONFINED COMPRESSIVE STRENGTH (PSF) PERCENT PASSING No. 200 SIEVE GRADATION SAND (%) GRAVEL (%) ATTERBERG UMITS PI,ASTICIfl INDE( (%\ IJQUID IIMIT (%) DRY DENSITY (pcr) NATURAL MOISTURE CONTENT (%) SAMPI,E LOCATION DEPTII(feet) TEST PIT roptimum moisture content and marimum dry density determined per ASTM D698. *t Unconfined compression test performed. on remold.ed. sample with moisture content = 16.6% and dry density = 112.5 fbs/ft3 +** Proctor Sample screened off 3/4" sieve. JOB NUMBER: 0Z-b136 TabIe 2. FALLING HEAD PERMEABILITY CALCULATION PROJEGT: West Parcel Development - Garfield County Landfill JOB NUMBER: 02-5136 DATE: 211312018 PERM NO.1 MATERIAL: Gravelly Sand and ClaY I SAMpLE: 1P Remolded Sample @ 98.7o/o of Maximum Std. Proctor Density & 1 .3o/o Below Optimum Moisture Content k = 2.303 * a*UA*t (log h1/h2) Start Time 113112018 (:A4 End Time 21121201815:25 Value Units H1=lnitial readino 102 cm a= afea 0.635 cm2 H2=final readino 92 cm A = Area of sample (brass liner)19.17 cm2 lloo h1/h2 0.04481 3.45 inches t = elapsed time 43852.50 seconds 8.7503 cm k = oermeabilitv 6.E2E-07 cm/sec