HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT
BLCO-O1 -25-9048
NUTRIENT HOLDINGS, LLC
REMODEL OF THE GREENHOUSE
9115 COUNTY ROAD 335, NEW CASTLE
%
1) THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS.
2) SANTTARY FACILITIES ARE REQUIRED TO BE PROVIDED FOR WORKERS.
3) A L|ST OF REQUTRED TNSPECTTONS WILL BE ATTACHED TO THE PLANS. THE
STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
HTTPS :/AAAAA/V. CO LORADO. G OV/PACI FIC/DORA/DPO EL CAL PLUMBING P
ERMITS
4) UNDERGROUND UTtLtry LOCATES rS THE RESPONSIBILITY OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILITY LOCATE HOT LINE.
5) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED
BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO
ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
6) SEPARATE SIGN PERMITS ARE REQUIRED FOR ANY EXTERNAL SIGNS. PLEASE
CONTACT THE COUNTY PLANNER FOR THE APPLICATION.
7) ELECTRTCAL CODE COMPLTANCE W|LL BE DETERMINED BASED ON FIELD
tNSPECT|ONS PERFORMED BY THE STATE ELECTRICAL TNSPECTOR, (303) 869-
3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE
WRITTEN DOCUMENTATION OF THE INSPECTIONS,
8) ALL EXTERIOR LIGHTING lS TO BE DOWNCAST AND SHIELDED.
9) SAFETY GLAZING IS NOT DESIGNATED ON THE PLANS. SAFETY GLAZING WILL
BE CHECKED DURTNG THE FRAMTNG AND F|NAL INSPECTION. (lBC 2406.4)
1O)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE
CONSTRUCTION WILL BE REQUIRED TO BE FIRE-STOPPED WITH LISTED FIRE
STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR
THE ASSEMBLTES AT THE FRAMING INSPECTION. (lBC 713)
11)A KNOX BOX tS REQUTRED TO BE MOUNTEDADJACENTTO THE FRONT DOOR.
PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION.
12)THE WALLS SURROUNDTNG THE TOTLET ARE TO BE NON-ABSORBENT FOR A
HEIGHT OF 48'AND 2'PAST ON EACH SIDE OF THE TOILET.
13)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO
GRrP, |NCLUDING POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6)
14)ALL FOOD SERVICE FACILITIES ARE TO BE LICENSED AND APPROVED BY
GARFIELD COUNTY ENVIRONMENTAL HEALTH DEPARTMENT. PROVIDE
APPROPRIATE APPROVAL PRIOR TO SERVING THE PUBLIC.
15)ANY EXPOSED FOAM tS TO BE COVERED WTH AN IGNITION BARRIER OR A
THERMAL BARRIER BASED ON LOCATION.
16) SHEET T1 SHOWS QUTTE A BtT OF FUTURE TNFRASTRUCTURE. THIS PERMIT
REVIEW IS FOR THE REMODEL OF THE EXISTING GREENHOUSE AND
ASSOCIATED SITE WORK FOR THIS STRUCTURE. NONE OT THE I-U IUI{E
INFRASTRUCTURE IS REVIEWED OR APPROVED,
17)THE PROPOSED BOTLERS WtLL REQUIRE ptpED COMBUSTTON AIR TO SUPPLY
THE UNITS.
18)THE EXISTING DOOR HARDWARE THAT SERVES EXIT DOORS SHALL BE
READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR
SPECIAL KNOWLEDGE.
19)F|RE EXTTNGUTSHERS ARE TO BE INSTALLED lN COMPLIANCE WTH IBC/IFC 906
20)THE COUNTY HAS RECETVED COMPLATNTS REGARDTNG L|GHTING ASSOCIATED
WITH THE SALES KIOSES. BUILDING PERMITS CAN BE HELD UP WHEN THERE
ARE KNOWN LAND.USE VIOLATIONS ON THE PROPERTY. IN LIEU OF THAT, THE
LIGHTS WILL BE REQUIRED TO COME INTO COMPLIANCE PRIOR TO THE FINAL
INSPECTION BEING SCHEDULED FOR THIS PERMIT. PLEASE CONTACT THE
COUNTY'S CODE ENFORCEMENT OFFICER FOR GUIDANCE.