Loading...
HomeMy WebLinkAboutCorrection CorrespondenceCrre*az, Colleen Wirth From: Sent: lo: Subiect: Attachments: Follow Up Flag: Flag Status: Bob Burkett <alltecbob@gmail.com> Tuesday, May 13, 2025 3:53 PM Colleen Wirth Re: BLRE-O4 -25-9176 - BURKETT FAMILY TRUST 1 1 59 CR 237 is now under review Property Owners Certificate.pdf; Cool Calc -2.pdf Follow up Flagged You don't often get email from alltecbob@gmail.com. Learn why this is important Colteen Thanks for taking the time with me on the phone. The information you shared witl be hetpfut in moving my project forward. I have attached the Property Owner's Certificate of Comptiance per question 2. Question #3 My wife is over the fatt pastures water so what will you need from her? Question #4 Timberl,yne has sent you revised drawings showing the crawtspace access. There witt be no fueted equipment in the crawl space; it witt be unconditioned space with no radiant or heat mats. Question #5 There wil,l, not be a pocket door between the barn and ADU that witt be a fire rated metal door. Question #6 Loft wil,l, be used as a part of the barn onty. Question #7 I have attached Coo[ Catc with the - 2degrees. After discussing Question #8 with you it seems tike I witt need to use the prescriptive path for our energy compl,iance. We wil,l, meet the minimum R vatue for insulation and our windows wit[ have the u-factor necessary for our area. Thanks foryour hetp Bob Burkett Atttec Services (970) 963-1182 Office (970)379-4609 Cett On Mon, May 5, 2025 at 9:56 AM Cotteen Wirth <cwirth@garfietdcountyco.gov> wrote: Buitding permit application: BLRE-04-25-9176 Burkett at Tract 8 Antlers Orchard (1159 CR237 outside Sitt, in unincorporated Garfiel'd County, Cotorado) Courtesy Message for Burkett FamityTrust project team: \ s \ N {t\ s 1 Hetto, this is Garfietd County Ptans Examiner, sending an update as I progress with examining ptans for your stick-buil,t barn / 650 sq ft ADU. Below is tist of questions I witl, need further detai[ (or cLarification) before reteasing an issued buitding permit: QUESTTONS BELOW: 1 . Viewing the historic stamped lmprovement Location Certificate from March 26,2021. 1.a. ls the 'untabeled' structure depicted roughty 180 ft EAST of an 'wood-frame' house represent the proposed BARN / ADU being submitted under this current buitding appl.ication? 1 .b. Does the 'untabeled' structure from tne 2021 ptan stitt reftect the currentty proposed location for said BARN I ADU? 1 .c. However, if the proposed BARN / ADU is not yet shown on this historic 2021 plan detait-- please resubmit (2)futt size copies of an AMENDED SITE PLAN graphicatl,y depictingwhere this BARN / ADU is going on the 10 acre site. Doing so witt attow me to complete the zoning compliance review for this project. Thankyou. 2. Ptease open the attached Link to view, fitt out and sign and date a Property Owner's Certificate of Compl,iance form for the proposed ADU. The fornr needs to be received before the buitding permit torbarnl ADU is issued. Thankyou. accessory-dwetti ng-u n it-com ptete-packet-2. pdf iG'**s** l-ropfllyqnrf ir-(!4!tl9.!9.at.!!l!!plli!!! A(essory Dw€lllng Unlt (ADU) 3. White reading through Fa[[ Pasture Water Association Dectarations for Shared Water System, on page 4, Section 3.2 Further Subdivision / Additionat Residences or ADU's, it seems afurther permlssio n or letter of approval by the Assocratio n is needed. l'm finding the original document from Marcn 20,2Q19 presumed for the originaI primary residence, but not anything from voting members of the Water Association to acknowl,edge acceptance of a further ADU? ( l'm erring on the side of caution, to hel.p avoid a possibte civil issue, surprise or delays during construction). 2 4. Submitted foundation and fl,oor framing ptans appear to suggest a 650 sq ft crawl space beneath the main [eve[ Accessory DweLting Unit. 4.a. Ptease identify proposed crawl space access opening size and location. 4.b. Please verify / confirm if any mechanicaI or propane fueted equipment witt be ptaced in the crawl space (hope not)? 4.c. Witt the crawl space be conditioned or unconditioned space? 4.d. Witt there be any inftoor radiant heat tubing or mats instatted in tiving floor space? 5. CONCERN: The main [eve[ floor ptan, seems to graphicatty depict a barn or pocket door (not a side-hinged door) between the ADU tiving space and adjacent non-residentiat attached garage or barn occupancy. lt is al,so unclear what fire-assembty materiats / products witt be instatted to separate the Living space from the garage. 5.a. Pl,ease provide watl, / door opening fire- rating and assembl,y detaits to show how the R-3 residence wil,L be fire-separated and protected from the U attached garcge occupancy. Ptease reference 2015 lnternationat ResidentiaI Code Tabl,e R302.6 and Sections R302.5 and R302.6. 6. Submitted ptans depict a 393 sq ft "toft" with 40 PSF tive load in the ftoor system, exterior exit stairs, interior guardrait and 'open to below' area. Loft use remains untabeted on drawings. 6.a. ptease confirm the intended use and occupancy of the 'toft'? 6.b. Witt second story'toft'space be a continuation of the garcge use and occupancy? 6.c. Or other use(s)? As no fire-assembties or separations were found in original, submission, more information is most hetpfut, thankyou. Winter Design Temperature:Minus 2 - Up to 7000 ft. elevation Minus 16 - Over 7000 ft. elevation 7 ln viewing the geotechnical, and engineering findings, it appears the proposed site elevation is roughLy 5,820 sq ft? lf that etevation is accurate, then be advised Garfietd County's Local,l,y adopted winter design temperature for the site wil,l. be a minimum winter design of MINUS 2 degrees F. 7.a. For further awareness, the COOL CALC manual J report shows a stightty lower site etevation at 5,548 ft ASL and a warmerwinter design of PLUS 8 degrees F. Ptease consult your mechanical 3 supptier or preparer of the COOL CALC report and resubmit an AMENDED MANUAL J with correct EIEVAI|ON AND A COrrECtEd WINTER DESIGN TEMPERATURE. 8. White a SIPS Roof R-Val,ue is provided, there remains insufficient references and detai[s to perform an energy code comptiance review for this project. Highty encourage and recommend submitting a separate ENERGY COMPLIANCE SHEET as noted on our residentiat checktist ENERGY COMPLIANCE SHEET REOUIREMENTA: Effeclive Jute 30,2023PI€as provadedolails showing how building compli€s / m6ets Gsfreld Countys odoptod 101I IECC ond SgEgt ;l@-[ Dgpict and shwdling th€ structufe s buiidinA lhemalgnvsloDe. Oulline should Clserlv showpodions otlhe building to be cmdiliored inside lhe €nv€lope {and hb€lor otheMse idonlify rny areos remoning un@ndilioned ollsado lhis €nvolops) Enorgy Complianc€ Plan shdb funhe, indude: Chosen En€rgy Complian€ Palh . e@qio!!!q Cross S€ctions ot iBulaled asemblaes incllding lho s6l€ct0d mat€rioll R,Value and U-Volu€s to @nrplywilh IRC Table R402.1.2 . U-Faclor Altsnatve: F\@ide a Re3chak R€pon r Tolol I LFnclor Allemalavc Prnvidc nntunrp 0€ncmlad qil)mdlal dFsion reFrls ond lrsnF.llrn chocklist ftrany RESNET ERI ,rd€x orothBr p8rforman@ palh desigDs Air sealing dehrls around openings, pipes, ponehlaons, joinb Fenestration U-fuctors Paovide mechoni@l system design d€toais includilrg propossd efficiency roles, typos of equipmenl, fuel lypes. lo@lids En€rgy €ftiebnl lightng spffifimlions - 9096 lo be hjgh-etf@cy (LED @mpl6s) l'lanual J Repoi requid for new building slrucluros and n6w squipment inslallations 8.a. What is the referenced ENERGY CODE? Code book, code year, Garfietd County is in Ctimate Zone???? 8.b. What is your chosen ENERGY COMPLIANCE PATH? Ptease state in writing on your plans. No notations were found. 8.c. Provide a ctear outline of the proposed buitding thermal envelope, so that it is understood what spaces are heated and unconditioned, and what if any cavities within the buil,ding footprint wi[[ remain outside the thermaI envetope? 8.d. No window / door fenestration U-factors found on ptans, ptease advise which page reference if this has been missed. 8.e. Witt the attached garage be heated? 8.f. Provide further stab ftoor / watt / ceiting insutation assembty detaits. 8.9. Garfietd County Buitding Code Requirements- residential, guide is offered to aid in understanding cu rrently adopted mini mums. NEXTACTION STEPS: Review ltems 1 - 8 and resubmit (2) FULL SIZE comptete sets of REVISED / CORRECTED INFORMATION and written responses to the Garfietd County Community Development front desk. 4 Reference BURKETT buitding apptication BLRE-04-25-9176, attn: Cotteen Wirth, Ptans Examiner. Colteen Wirth Buitding Plans Examiner Garfietd County Gommunity Devetopment 108 B'h Street, Suite 401 Glenwood Springs, CO 81601 (970) 945-1 377 ext 1 61 0 cwi rth (oga rf ietd cou ntyco.gov Staff emait addresses are shifting to end in @garfieldcountyco.gov. However, personaI names/prefixes on email, addresses wil,l, remain the same. Ptease update our contact information domain. 5