Loading...
HomeMy WebLinkAboutEngineer's Memo 02.20.23KURTZ & ASSOCIATES. INC. STRUCTURAL CONSULTANTS 5012 County Road 154 Phone (970) 945 6305 Glenwood Springs, CO 81601 MEMORANDUM Date: Feb.20,2023 (2) Pages To: Garfield County Community Development Depertment Copy: G.W. Shaver Constructiono Inc. Re: As Built Framing Notes: Gerbcr Residence at 170 Midland Loop, Aspen Glen Subdivision, Garfield County' CO. Our o{fice is the structural design engineer of record for the noted project, and as such issued construction documents on Oct. 12,2021. We also issued three (3) revisions to the construction documents (03117/22, A4l2ll22 & l2l08/22). The following comments address concerns raised during Garfield County's final framing inspection. I. Main Floor Framing: Near Grid Line'D,' approximately 5 ft, west of Line'9,' a electrical outlet was installed in the living room floor. The top flange of a BCI floor joist was cut. The impacted joist should be header off. See typical header detail R/S-6. II. Mein Floor Window Openings: The master bedroom suite occupies the south end of the home's primary wing. In the adjacent office and the master bath a series of 2 ft. & 3 ft. wide windows were specified with minimum ((3)-2x8) headers and (l) Jack + (l) King header supports. These window openings were framed and then in-filled as the windows were eliminated for architectural purposes. The windows as framed and in-filled are structurally acceptable. The 3 ft. wide man-door between the master bath & master bedroom was replaced with a pocket door. The header at this door on Grid Line '7' was upsized from (3)-9.ll2" LVr-'s to (3)-l1.7/8" LVL's. The dining room occupies the north end of the home's primary wing. At the north wall of the dining room (Grid Line'A') two window openings were eliminated and the wallwas framed with 2 x 6 studs at 16" O.C. This is structurally acceptable. The laundry room is on the west side of the interior stair and the north wall of the laundry is Grid Line'A.' The structural documents speci$ a 4 ft. window in that wall, but the drrchitect specified a 2 ft. wide window. For the as built 2 ft. opening, the minimum (3)-2 x 8 header with (l) Jack + (l) King each end is structurally acceptable. Windows relocated at the north garage wall (Grid Line 'A'): see attached partial framing plan. IfI. Upper Floor Framing: For framing revisions at the east garage wall (Grid Line '3') and the garage door headers see attached partial framing plan. IV. Upper Roof Framingl The interior wall on Grid Line '3' (above the east garage wall) was moved 5.112" to accommodate a bathroom redesign. See attached partial framing plan. A WlO x 26 spans 16 ft. on Grid Line 'C'. The WlO is at a roof pitch break ( rcl10 to 4ll2). The west end of the WlO bears at Grid Line '7.' The bearing of the WlO is a slight variation of the typical WlO to top plate bearing (Detail R/S-9) and includes two timber strand plates. The as built bearing is structurally acceptable. o2'2o -2 7 I: {,7 44It t