Loading...
HomeMy WebLinkAboutBlower Door Test Report 6.3.2025C31al1 J BUILDING LEAKAGE TEST Frostbusters & Coolth Co. PO Box 94 Basalt, CO 81621 Email: fritzd@frostbusters.com Website: frostbusters.com ,�.�l,�lit sr<��� • COOL ' Date of Test: 6/3/2025 Test File: 15 Horseshoe Ln Blower Door Test 6-3-2025 Customer: Janckila Construction, Inc. Technician: Fritz Diether 50 Sunset Drive Project Number: Final Blower Door Test Basalt, CO 81621 Phone: (970) 927-6714 Building Address: Westerfield Residence Email: alex@janckilaconstruction.com 15 Horseshoe Lane Website: janckilaconstruction.com Carbondale, CO 81623 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve 4. Test Settings: 5. Accuracy Level Infiltration Estimates 1605 CFM50 (+/- 2.9 %) 1.40 ACH50 w- 88.2 in2 LBL ELA @ Flow Coefficient (C) = 139.7 - 18.0 %) Exponent (n) = 0.624 ( +/- 0.050 ) Correlation Coefficient = 0.99513 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate 2. Estimated Design Infiltration Rate Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 96.2 CFM 0.08 ACH 19.2 CFM per person From 2018 IECC: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding (3.00 ACH50) three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with RESNET/ICC 380, ASTM E779 or ASTM E1827 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Building Passes at 1.40 ACH50 Winter: 168.7 CFM Summer: 114.9 CFM 0.15 ACH 0.10 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: Base Rate: 78.5 CFM 78.5 CFM BUILDING LEAKAGE TEST Page 2 of 4 COOLSH Date of Test: 6/3/2025 Test File: 15 Horseshoe Ln Blower Door Test 6-3-2025 Building Information Volume 68750 Surface Area Floor Area 4095 Height 29 # of Bedrooms 4 # of Occupants 5 Year of Construction 2025 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.80 Energy Climate Factor 19.00 Heating Degree Days 9000 Cooling Degree Days 28 Design Winter Wind Speed 1.6 mph Design Summer Wind Speed 10.9 mph Design Winter Temp Diff 77 deg F Design Summer Temp Diff 11 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 p9S S UST 44��v �V o. BUILDING LEAKAGE TEST Page 3 of 4 cool Date of Test: 6/3/2025 Test File: 15 Horseshoe Ln Blower Door Test 6-3-2025 Depressurization Test: Environmental Data Indoor Temperature (OF) Outdoor Temperature (OF) Altitude (ft) 70.0 64.0 6056.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) 0.4 n/a n/a -60.0 -60.0 100.0 -55.0 -55.0 91.0 -50.0 -50.0 76.0 -45.0 -45.0 66.0 -40.0 -40.0 57.0 -35.0 -35.0 47.0 -30.0 -30.1 40.0 -25.0 -25.1 28.0 -20.0 -20.1 222.0 -15.0 -15.1 174.0 -0.3 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1795 1830 1.7 Ring A 1715 1748 2.6 Ring A 1571 1601 -0.3 Ring A 1466 1494 -0.6 Ring A 1365 1391 -0.4 Ring A 1243 1266 -1.5 Ring A 1149 1171 0.2 Ring A 965 984 -5.6 Ring A 882 899 -0.9 Ring B 782 797 5.1 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters BUILDING LEAKAGE TEST Page 4 of 4 COOL-O Date of Test: 6/3/2025 Test File: 15 Horseshoe Ln Blower Door Test 6-3-2025 Comments None