Loading...
HomeMy WebLinkAboutBlower Door TestTesting Company: Name: Address: Technician: Name:Brian Chesney Credentials:BPI Certified ID#5068969 Email:c5energygj@gmail.com Building Information: Project ID:177 eagle ridge dr. battlement mesa Address:177 Eagle Ridge Drive Battlement Mesa, Colorado 81635 Geo-Tag Data:Latitude: 39.443663 Longitude: -108.029422 Timestamp: 2025-05-28 08:57:55 Customer Information: Name: Address: Measured Leakage:2.61 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:Blower door Purpose of Test:Envelope (IECC) Measured CFM50:1,013.3 Effective Leakage Area: 55.7 in² Building Volume:23,308.0 ft³Enclosure Surface Area: 0.0 ft² Coefficient (C):79.7 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 70 °F Altitude: 5,372.0 ft Outdoor Temp: 76 °F Time Average Period: 10 seconds Test Date and Time:2025-05-28 09:02:55 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.3 -50.0 -50.8 -50.5 -28.9 979.8 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc.