HomeMy WebLinkAboutBlower Door TestResidential Air Infiltration Test Report
Test date:5/29/2025
Project name:Coffey Residence
Address:115 Sundance
Garfield
Code:2018 IECC
Conditioned volume:51,962 Cubic Feet
Attic:Vented
Crawlspace:conditioned
Garage:excluded
Measured airflow:2,464 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:65
Temperature; Outside:68
Elevation:6,074
Corrected airflow:2,554 CFM50*Cubic Feet per Minute at 50 Pascal
2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:2.9 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
final blower door