Loading...
HomeMy WebLinkAboutBlower Door TestResidential Air Infiltration Test Report Test date:5/29/2025 Project name:Coffey Residence Address:115 Sundance Garfield Code:2018 IECC Conditioned volume:51,962 Cubic Feet Attic:Vented Crawlspace:conditioned Garage:excluded Measured airflow:2,464 CFM50 Cubic Feet per Minute at 50 Pascal Temperature; Inside:65 Temperature; Outside:68 Elevation:6,074 Corrected airflow:2,554 CFM50*Cubic Feet per Minute at 50 Pascal 2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal Tested air leakage rate:2.9 ACH50 Air Changes Per Hour at 50 Pascal Test code compliance:PASS Test notes: Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL * Test results have been corrected for elevation and air density temperature differential. final blower door