HomeMy WebLinkAboutBlower Door Testretrs Retrotec rCloud Ouality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 2.43 ACH50 (481 .68 CFM50 * 60 / 1 1869 ft3) Tarqet < 3 ACH50 Test lnformation Test Name Test Date Export id Company Name Technician Name Technician Email Building lnformation Address City State Ziplpostal Code Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre-test lndoor Temperature Pre-test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Volume 1 360 County Road 331 2025-03-18 09:32 AM (PDT) CVD1 L6Y6 Dexter Diagnostics Amanda Poindexter dexterdiagnostics@gma i l.com 1 360 County Road 331 silt co 81652 United States Not available 5489 ft Yes 39.527 7 93, -1 07 .66307 8 Tester location not verified Not available Retrotec 5000 5FN1 0536s Retrotec DM32X 502769 65'F 37 "F 18 MPH 100.4 KPa 913 ft2 11869ft3 EEretrs Retrotec rCloud Test Results Summary Test Type Flow Reference Pressure Time Averaging Corrected Flow Air Changes Per Hour Percent Uncertainty Correlation, r lntercept Slope, n Test Results Test Data Set 1 Flow Direction Gauge Location Single Direction Multi Point Blower Door Test 50 Pa 1 0 seconds 481.68 CFM @ 50 Pa 2.435 1.9o/o 0.998 30.319 o.707 Depressurize lnside Baseline initial Baseline Duration Average baseline 1 0 seconds -1.5 Pa -2.51 -1.89 -1 ,49 -1.34 -1.43 -1.43 -1.41 -1.13 -1.2 -1.13 Measured Pressure (Pa) Fan Pressure [5000 - B2l (Pa) Fan Pressure [5000 - Ba] (Pa) Flow (CFM) -15,61 7 4.O7 -22.46 112.85 -28.95 148.47 -37.95 235.11 297.68 348,24 45,61 413.97 Measured Pressure (Pa) Fan Pressure [5000 - 82] (Pa) Fan Pressure [5000 - Ba] (Pa) Flow (CFM) -46.42 -54.03 -61.78 58.93 469.64 78.05 544,32 89.15 586 Baseline, final Pa Baseline Duration Average baseline 1 0 seconds -2.3Pa -1.97 -2.09 -2.28 -2.39 -2.34 -2,36 -2.32 -2.3 -2.41 -2.58 ECrgtrgr Retrotec rCloud Test Notes No notes entered Flow Equation Parameters - Retrotec Calibrated Flow Parameters Certificate Number: 2O2408291152-5FN105365 Fan Last Calibrated: 2O24-Oq-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated: 2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self-referenced fan or when the room pressure is negative. lf using a fan which is not self-referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. lf PrA is greater than 0 or fan is self-referencing: FP = lPrBl - PrA lf PrA is less than 0 or fan is self-referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x lRPl) FP = fan re, RP = room re Range Open A B8 N 0.4990 0.5030 0.5270 K 555.2054 290.8751 121.5413 K1 0.0000 0.0000 0.0000 K2 0.3000 0,4000 0.7000 K3 0.0000 0,0000 0.0000 K4 1 1 1 MF 10 20 35 flow =P-RPxK1 +K3x xK4X Range B4 82 B1 874 847 B.29 flow =x A 0.0000176573 0.0000025309 0.0000027369 0.0000007960 0.0000002690 0.0000001110 +X B -0.01530302 -0.00466154 -0.00313712 -0.00095010 -0.00035905 -0.00014900 x +D+ C 6.2742 2.7545 1.4891 0.5900 0.2435 0.0920 D 138.42 25.71 10.71 18.00 12.05 4.40 F 0.59 0.92 0.45 0.15 0.09 -o.o2 K2 0.8000 1.0000 1.0000 0.8000 1.0000 0.6000 MF 40 50 60 35 50 50 G 50 50 50 25 25 25 +X