HomeMy WebLinkAboutEngineer's OWTS Design PlanINFILTRATOR SYSTEMS INC. INFILTRATOR SYSTEMS INC. QUICK4 CHAMBER QUICK4 STANDARD CHAMBER SAME END SERIAL DISTRIBIBrION. TRENCH DETAIL (PLAN VIEW) NOT TO SCALE SLOFE WICK4STANDPADCHAMBM TANK- INSPEC,IDNP03i 3, � R,rcrmiq 5I C PffE QUICK4 STANDARD MULTIPORT END CAP MULTIPORT END CAP r MATORSlKTEna. INC. rv6Bxl5NE. PARR ROM INFILTRATOR SYSIEME INC. INEUTRATOR$YVEN INC. 6BIIl5Nb9PMFRPAO P.o.ld'(7 QUICK4 CHAMBERS P.O.BOX Ibe INFILTRATOR SYSTEMS INC. CC inYBRO(SR; Cio6m5 SAMEENDSERIAI oLD snveaoorc,ttams YQUICK4STANDARD PLEASE NOTE ALL INFILTMTOR CHAMBERS MAYBE BE USED IN THIS MANNER rx.�em sn-rao6 DETRIBATHON Px,ImaI22Rdld6 CHAMBERDRAIL EFIMAIBn=mBI www.luFIMaz M.CoM, TRENCH DETAIL wwrv.wxLmArounRee4s.eoen Scats NOTED SCALE Checked BOP Scale NOTTOSCALE Checked BCP pate 03/31/2006 Q4 SAME END Dale 0313072006 04 STDTECH Drawn ST. KJB Sheet 1 Of 1 Drawn fly: KJB Sheef 1 Of I INFILTRATOR SYSTEMS INC. QUICK4 CHAMBER QUICK4CHAMBER SLOPED SERIAL DISTRIBUTION INSPECTION PORT DETAIL CROSS SECTION TYPICAL INSTALLATION DETAIL NOT TO SCALE (Not toSple) ORIGINAL GRADE DIFFERENT ELEVATION OVERFLOW Option A: CHAMBER RISER TO GRADE Option B: INSTALLATION WITH VALVE BOX ESTABLISH VEGETATIVE COVER IZ MIN_H-10 LOAD AREAS "av itI 6- MIN., NON -TRAFFIC AREAS iRRwnaovuvi mom, o-rs�oE WTAS£"BLYE OL,CN4 STPNOPR o-` 'q"i cPacNPE (a >{��v� .- ''�` ���':i. TowPPoNrem� I^K�. :'sS,� 12" L s.:., wcxlf wrro En -iiN;::"O aI.Tor,r SI SPACING CENTER-TPER %{y FbTP WCPIFEONTCPK 4x0.EBPW T£ST4-PJCPIF MTPCP - INS T IusPECTCNfYIRTNAT. CODE PER CODE MENreaT c:=."o-..I�"avcrE�Ir+LLi sP�wcewmn ,�E"ciRas sE wr�i svuwmo- PLEASE NOTE: ALL INFILTRATOR CHAMBERS MAY BE USED IN THIS APPLICATION IxxnRAToksrsTenss, rvc. m1MATORsvn.,wC. 6 BY6NfSS PARK ROM INFILTRATOR SYSTEM1E INC. 6 Bx6NES5 PAIllt.l r.o.eox veB QUICK4 CHAMBER Po.Bw P6e INFILTRATOR SYSTEW INC. ..'a ROOCcio64ls vx. I., z2, u SLOPED SERIAL DIST. otosnveacoK. cT mas PH.Imol ni.bas QUICK4 STANDARD Ex. N.)sn-mm DETAIL CROSS SECTION f%. Ieml sv2g,pl INSPECTION PORT DETAIL wwx.wfamATORsysriaxooM www.wrnwAToresrsTEna.mm Scale NOT TO SCALE Checked BCP Scab NOTTOSCALE Checked BOP Date 03/31/2006 Q45ERIAL-% Dole 05/19/2006 ACAD E10 fl 1�A., Drawn By: KIN Sheet 1 Of I Drawn By: KJB Sheet 1 Of 1 " J , pi --"------- 16. -4 U Profile Holes (2) 1 � ro �-; Q4Infiltrators (2),4Runs'of Qcw," ell 38 total / r Pv ADO INFILTRATOR SYSTEMS, INC: PLACEMENT OF FILL MATERIAL WITHIN ZONE OF DISPOSAL CONFINING LAYER NOT APPLICABLE TYPICAL TRENCH DETAIL SHEET NOTES: 1) REFER TO MANUFACTURER FOR ADDITIONAL INSTALLATION REQUIREMENTS @ WWWANFILTRATO R.COM FOR QUICK 4 SERIES PRODUCTS. 2)REFER TO VALLEY PRECAST FOR ADDITIONAL TAN K, PUMPING AND CONTROL SYSTEM REQUIREMENTS @ WWW.VALLEYPRECAST.COM OR (719) 395-6764. 3)ALL SEPTIC ELECTRICAL TO BE BY VALLEY PRECAST OR OWNER'S MASTER ELECTRICIAN EXPERIENCED IN SEPTIC PUMPING SYSTEMS AND NEC REGULATIONS. qW / c �.� /y 9y \ /�F OF MSE GRAVITY / \ , S WALL H<4' d /� BOT WALL 8974 i . TOP WALL 8878 I �/ �18 F� ���I/ -1 o.00' - ) T F FN Clean i a / Out �r 200AMP Ij 11 'n METER LOAD ; 1 acc cc G CENTER-W/ ''i : a- Do Qr qy, DISCONNECT New 1.500 aallon precast concrete septic tank with bio filter 58(W 2% min. inspect i - Fernco Shear Guard Union 0 20' 40' 1" PURE CORE WATERSERVICE 7 WELLHEAD �2) 2" SCH.80 r' .` WELL PERMIT #166915 G/ELEC. .� O� J/r 6 ' .� - 1000 GALLON .# PROPANE / ` t . TANK Ile, , POWER POLE r SEPTIC PLAN BROCIC CIVIL, LLC Professional Services P.O. BOX 23 Eagle, CO 81631 Cell 970-471-2121 JUNE 16, 2025 7W Christian Ranch, LLC. 3412 CR 151, Garfield County, CO PN: 186328100118 DESIGN CALCULATIONS FOR DOMESTIC LOADS REFERENCES Eagle County Public Health Agency On -Site Wastewater Treatment System Regulations adopted July 10, 2018 ("Regulations"). Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 100243. DESIGN FLOWS Number of bedrooms = 3 Number of persons per bedroom = 2 (design flow) Single Family Residential Design Flows = 75 gallons/day/person Q design = 3 bdrms x 2 persons/hdrm x 75 gallons/person/day = 450 gpd PER 43.6 TABLE 6-1, USE 450 GPD C i JCW ID &-S D 1 S 0 0-C.4 , SOILS PROFILE (Visual and tactile investigation): Soil Type 2 ( See USDA) - From profile hole 1 - sample at 4 ft. Ribbon 17 man Profile Holes (2) Textural Classification 0.0 to 1.0 ft Topsoil with heavy organics 1.0 to 8.0 ft Silty loam and sand, single grain structureless, granular (USDA) No groundwater. No wetting of soils or mottling in profile holes PERCOLATION TESTS: Visual and tactile evaluation of the treatment soil indicates silty loam, sandy with a percolation rate of 15 IMlinutesnrich, with no limiting layer. INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION Given this information, the residence would be best served by a chamber system in serial trench distribution. Treatment Level 1 Effluent: Per Tables 6-2: 10-1. Surface of Soil Treatment Area (STA) shall be based on LTAR and not the percolation rate. Soil Treatment Area = Design Flow (gals/day)/LTAR gal/day/SF. Long Term Acceptance Rate is estimated to be 0.7 GaVday • Reductions: (per 43.10,D. Tables 10-2 & 10-3) Trench serial chambers: 0.7 • Design Flow = 450 GPD / (0.7 Gal/day/SF) X 0.7 = 450 GPD • Using standard Quick 4 Infiltrators: 450 GPD / 12 SF per infiltrator = 38 infiltrators • Trenches shall be (2) runs of (19) infiltrators; Total (38) • Valley Precast 1000 gallon tank • Chamber Product to be Infiltrator Systems, Inc. "Quick 4" Low Profile Chambers. SEPTIC TANK: Per table 9-1, for a maximum 3 bedroom residential structure, Minimum Tank Capacity is tMallons in the first 2 chambers. Pr osed Valley Precast Tank IND gal 2 compartment: Inlet side Wn gallons and Outlet,$07 gallons. Water tightness per Section 9, ASTM C 1227-12. 667 323 INSTALLATION Install all components to the required setbacks required by regulations. No over excavation allowed for septic tank or trenches. DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 62.33 ft' • f c @ 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with w }-• table less than 2' below grade • Meets C1644-06 for resilient col • Inlet and Outlet identified above • Delivered complete with internal • PVC or concrete risers available • Secondary safety screen available PVC riser • Option of pump or siphon install ALLOWABLE BURY (Based an Water Table) WATER TABLE ALLOWABLE EARTH FILL 0' - 0" 3' - 0" 1'-oil 3'-0" 2' - 0" 4' - 0" S-0" 4'-0" DRY 4' - 0" CHAMBER TRENCH CONSTRUCTION: Dig trench to geotechnical average depth to top of silty, sandy loam (max 4 ft); Engineer to inspect. Install chambers level in (2) runs of 19 chambers. Backfill the chambers and all voids to top of chambers. Import may be required for proper backfill. TOP SOIL CONSTRUCTION: Back fill over chambers with 12 inches of high organic top soil and reseed to native vegetation. Do not compact top soil! Mound topsoil for positive runoff, 1 ft. -18 inches. SEPTIC TANK & PIPE CONSTRUCTION: Install septic tank level with 5" sand gravel bedding. Install the delivery pipe from the residence to the septic tank minimum 2% slope, Schedule 40 PVC (preferred) (ASTM D 2665) or SDR 35. Septic tank to have risers brought to final grade and shall have a secure locking mechanism. Glued fittings for both pipe types due to tree roots. ALARM: A visual and audible alarm shall be incorporated into the controls and electrical connections. Alarm to be in an open area or area easily visible. NOTES: I. The building sewer line from the house to the septic tank shall have a slope of inch per foot (2D/e). Bends in the building sewer shall be limited to 45 degrees. 2. Use topsoil for vegetative cover. 3. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturer's recommendations. 4. Vehicle traffic, animal concentrated loads and irrigation over the system is prohibited. Fencing advised. 5. The Septic System Installation shall be inspected by the Design Engineer prior to backfill. Installer to call ECEH. 6. All installations shall meet the Arles and regulations of the Eagle County Environmental Health Department. 7. Electrical requirements of alarm to be determined by Electrical Contractor prior to construction. 8. The Bin effluent screen shall be installed in the outlet tee of the second chamber with both tees visible from the access portals. Screen shall be maintained annually or as needed. 9. Pump septic tank every 2-3 years minimum to prevent deterioration of concrete. 10. Installer must be licensed installer in Eagle County; see permit. MINIMUM DIMENSIONS TO FACILITIES ACTUAL (MIN. REQ'D) SEPTIC TANK TO BUILDING 60 FT (5 FT) SEPTIC TANK TO WATERLINE 20 FT (10 FT) SEPTIC TANK TO TRENCH 10 FT (10 FT) SEPTIC TANK TO SPRING/WELL NA (50 FT) ABSORPTION TRENCH TO SPRING/WELL NA (100 FT) ABSORPTION TRENCH TO BUILDING 25 FT (20 FT) ABSORPTION TRENCH TO WATERLINE 25 FT (25 FT) ABSORPTION TRENCH TO IRRIGATION NA FT (50 FT) ABSORPTION TRENCH TO PROPERTY LINE 90 FT (10 FT) BUILDING SEWER TO WATER LINE 10 FT (10 FT) See 43.7, Table 7-1 for further information and requirements if changes are made to assure proper clearances. SANDY LOAM 60% SAND 30% SILT 10% CLAY Top View 08« Section View Digging Specs Invert Dimensions Net Capacity Net Weight 13' Long x 8' Wide Inlet Outlet Length Width Height Inlet Side Outlet Total Lid Tank Total 56" below inlet 56" 53" 132" 68" 68" 1 gal gal ),591'gol 3600 Ibs 11180 Ibs 14780 IDS OE ON 0 � N J I O -o N[`J >X ^Y Um0 O0 O �0. U00 O0- WW wU> m LL Q L W0 Z Q J 0_ /Ldn VJ U) z 0 D > w of �7-000 n7-U� Q 0 U z­_0n <ZUc0 �0WM -UJ >-:)N Z00 INQZ U W� 0` W o b 0 Z LU CL w rl }I w Df ram >LLJ 4 O Z y Z C W EL to w I- aw= x SHEET SS1