HomeMy WebLinkAboutEngineer's OWTS DesignI29 CAINS LANE CARBoNDALE,CO 81623 970.309,5259 cARLA. OSTB ERG@GMAllL. COM ttf,ll"t' l(' ('( )NsI I r.'l'tN(i May 21,2025 Project No. C1954 Matt Jurmu mad.iurmu@bouldercs.com Subsurface lnvestigation and Onsite Wastewater Treatment System Design 3-Bedroom Residence Lot 21, Mountain Springs Ranch Garfield County, Colorado Matt, GBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 35.139-acre property is located outside of Glenwood Springs, in an area where OWTSs and wells are necessary. Legal Description: Section: 29 Township: 6 Range: 89 A TR lN SW AKA LAT 21 MOUNTAIN SPRINGS RANCH Parcel lD: 21 85-293-00-1 09 SITE CONDITIONS The property is currently undeveloped. A 3-bedroom residence is proposed. The residence will be served by a private well on the property. The well had not been drilled at the time of this design but will be greater than S0'feet from the proposed septic tank and greater than 1O0-feet form the proposed soiltreatment area (STA). The proposed soil treatment area (STA) location has an approximate 15 percent slope to the south. The proposed area is vegetated with sage, native grasses, and sparse trees. High groundwater was encountered in the area of the proposed STA and mounding will be necessary. There should be no traffic or staging of material over the future STA slte to avoid compactlon of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on April 7,2025 by digging one soil profile test pit excavation (Test Pit). A visual and tactile soil analysis was mmpleted by Cada Ostberg at the time of excavation.l The materials encountered in Test Pit #1 consisted of moist, dark brown topsoil to 2.0-feet, underlain by moist, reddish brown clay loam to a maximum depth explored of 6,0-feet. Free groundwater entered the uphill side of the test pit at approximately 1-foot below grade. ' Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 2 A sample of the soil was taken from Test Pit #1 at 3-feet below grade, Soil structure grade was moderate. The soilformed a ball and a ribbon 1 to 2-inches in length before breaking, Soils were very moist and difficult to run the tactile evaluation. The soil is consistent with Soil Type 3, Clay Loam, with moderate structure grade. Mounding of the STA will be necessary due to the presence of high seasonal groundwater. A mounded, unlined sand filter with a minimum of 3-feet of sand filter material to create the required separation between the infiltrative area and high season groundwater is proposed. A long-term acceptance rate (LTAR) of 0.65 gallone per square foot will be used to design the STA. Page 3 DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD LTAR = 0.65 GPDiSF 450 GPD / 0.65 GPDiSF = 692 SF Please see enclosed Mound Sysfem Design Spreadsheef forslope information The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD will be used, For the purposes of this OWTS design, Benchmark Elevation at grade 7698.06' has been established as 100' (Finished Floor). CBO lnc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. *Elevations are upon standard OWTS installation practices. Component elevations may change during installation due to site conditions. Minimum grade refers to piping between components. The 4{nch SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2o/o grade to the septic tank. The system installation will include a 1OOO-gallon, two-compartment lnfiltrator@ poly septic tank with an Orenco@ Biotube Effluent Filter followed by a 500gallon, single-compartment lnfiltrator@ poly Pump Vault OWTS Gomoonent Minimum Elevation Approximate horizontal distance 3f i min. 2o/ofall I min.7.75" fall Primary Tank lnlet lnvert Approxirnate horizontal distance 15'/ min. 1o/o rise I min. 1.875" rise Automatic Distributing Valve Approximate horizontal distance 24' I min. 1o/o tall to STA / min. 3" fall lnfiltrative Surface Page 4 and an Orenco@ PF3005 pump. The floats should be set to dose approximately 65 gallons each pump cycfe, allowing approximately 2 gallons of drain back. The control panel for the pump must be located within line of sight of the septic tank. An electrician will be responsible for wiring the pumping system and the contractor will be responsible for connecting the plumbing. This office should be contacted for start up of the system to verifu its functioning and to perform a squirt test prior to use of the system. P Table Effiuent will be pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco@ automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1o/o grade for proper drain back into the tank after each pump cycle. The ADV must be placed at a high point in the system in an insulated riserwith access from grade. Screened rock must be placed below the ADV to support the ADV and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance. Effluent will be pressure dosed to through 1.5-inch diameter distribution lines to two 10' x 35' beds (which can be set end to end with distribution piping extending f in from the touching ends of the sand filters. A minimum of 3-feet of sand filter material beginning 1-foot below native grade the uphill side of the sand fllter. Sand filter material must be clean, coarse sand, all passing a screen having four meshes to the inch. The sand must have an effective size between 0.15 and 0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting ASTM 33, for concrete sand, with three percent or less fines passing 200 mesh sieve may be used. A gradation of the sand medla must be submitted to this office prior to obtaining the sand. Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 3-feet on center, installed on the GeoMatrM with the filter fabric over the laterals. Laterals should be placed 2-feet from the edges of the bed with 3.0-feet between the laterals. Laterals will be connected with 1.5-inch diameter level manifolds. Three 39" wide GeoMatsrM must be placed on the 10-foot wide beds. All material associated with the GeoMatrM installation must be proprietary products associated with the GeoMatrM, including orifice shields and geotextile fabric. Manufacturer instructions must be followed regarding installation of the GeoMatrM. Each 1.S-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing. Valves should be placed in a 1O-inch sprinkler box for access. Laterals must be covered by a soilseparation fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There shall be no cobble-sized (>2.5") or greater rock in final cover over the GeoMatrM. Inspection ports must be placed at each corner of each bed, Ports may be cut to grade and covered with a valve box for access. The mound must have a minimum 3:1 slope (horizontal:vertical); therefore, the basalarea will extend approximately 9-feet beyond the sand filter the downhill side and ends (with a mound height of approximately 3.S-feet above native grade). Soils in the sloped perimeter areas of the mound must be well draining and able to support vegetative growth. This soil must be approved by this office prior to installation. The mound must be crowned in a manner to promote drainage off the STA. More details are provided regarding sloping areas off of the mound and depth of sand as the sand filters are built into the hillside in the enclosed Mound Sysfem Design Spreadsheet and W3.0/1 and 2 Mound Plan and Section Views. Dose Range Max = 114,5 gal, (450 GPD x 25o/o + 2 oal drain back) Min. 56 gal. (13.5 gal x 4) + 2 gal drain back Dose Setting 65 gallons/dose 2 gallons drain back (15' I 1.5" diameter oumo line) Float Separation 500-9allon, single-compartment lnfiltrator@ poly pump chamber 5" on/off float separation Pump Criteria 24.4 gallons per minute (GPM)18.0 feet total dynamic head ffDH) Page 5 COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO lnc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. Construction must be according to the jurisdiction's adopted On-Site Wastewater Treatment System Regulations, the OWTS Permit, and this design. PERMIT APPLICATION INSTRUCTIONS An OWTS Permit Application must be submitted to Garfield County Environmental Health Department. https://www.qarfield-county.com/environmental-healthifilesgcco/sites/16/0UffS-Application-Complete- Packet-Dec.-2019.pdf. lf the OWTS Permit Application will be submitted with a Building Permit Application, it should be submitted directly to Garfield County Building Department. All questions regarding permit submission can be directed to Garfield County Environmental Health Department, 970-945-661 4 x81 50. I NSTALLATION CONTRACTOR CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. COMPONENT MANUFACTURER MODEL NO.COMMENTS Septic Tank Effluent Filter Pump Chamber nfiltrator@ Orenco@ lnfiltrator@ rM-1060-2CP 4-inch diameter rM-500-1cP-HH 1O00-gallon, two- compartment septic tank Fullsize 500-gallon, single- :ompartment pump ihamber with HH pumo Pump Orenco@ PF300511%HP 120 Volt Biotube ProPak Pump Packaoe OrencoG)BPP30DD Vault, Filter, Control Panel ldemand dose) Tank Risers and Lids Orenco@ Double-walled PVG Risers and rids (24" diameter) ADV Orenco@ v64024 1.5" lnlet and Outlets ADV Riser and Lid Orenco@ Double-walled PVC Risers and Lids (30" diameter) Flushing As$embly orencoGJ 1.5" diameter (2) 45" or 90" long sweep only (6 total) GeoMatrM GeoMatrix systems, LLC 39" wlde sneets 21u'GeoMat'M and 6U onflce rhields Page 6 INSTALLATION OBSERVATIONS CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO lnc. should be notified 48 hours in advance to observe the installation. ln an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, lncluding path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed obJects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQU IREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular inigation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS" Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS, The OWTS is engineered for domestic waste only, ADDITIONAL CONSTRUCTION NOTES lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high- water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated, Page 7 Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade, Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. lf soil conditions encountered are different from conditions described in report, CBO lnc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation, Please call with questions./GCROAIK Sincerely, I'.t), fio.t r;o ,\firc&, ft) tlr GBO lnc, '17o. tio,oiTt f k re/r,r_1,[r,crotr&r.rorrr/.t,rl,conr Rer,ielvecl By: (:',&,r,Ly A#fu"8 Carla Ostberg, MPH, REHS Kachayla R. Cronk, PE, Colomdo License No. 61440 6il40 0h It{It 1 rnroa ? i\ Pump $election for a Pressurized System. Single Famity Residence Project Lot 21, Mountain Springs Ranch Parametere 300 Discharge Assembly Size Transport Lenglh Before Valve Transport Pipe Class Transport Line Siz6 Distributing Valve Model Transport Length Aft6r Valv6 Transport Pipe Class Transporl Pipe Sizo Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Siz€ Number of Laterals per Cell Lat€ral Length Lat€ral Pipe Class Lateral Pipe Size Oriflce Size Orifice Spacing Rosidual Head Flow Mster 'Add-on' Frictkln Losses Calculations 1.25 15 40 1.50 6402 24 40 1.50 2 6 40 1.50 6 33 40 1.50 5t32 3 5 None 0 inches inch6s inches fset inches inches feet feet feet feet incheg inch6s feet 250 150 100 50 0 PumpData 5 10 o ,fl To t a!o .c E Gtr o .E P 240 feet feet Minimum Flow Rate per Orifice Numbsr of Otifices per Zone Total Flow Rats per Zone Numb6r of Latorals per Zone 7o Flow Differential lsVLast Orifice Transport Velocity Before Valvo Transport Velocity Afier Valve FrlctionalHead Losses 0.68 gpm 36 24.4 gpm 3 0.5 Yo 3.9 fps 3.9 fps Loss through Discharge Loss in Transport Before V€lve Loss through Valve Loss in Transport after Valve Loss in Manifold Loss in Lateralg Loas through Flowmeter 'Add-on' Friction Losses Plpe Volumee 4.2 0.5 5.4 0.9 0.1 0.1 0.0 0.0 0 feet foet feet feet feet feet feet f6et gal6 gals gals gals gale gals 15 20 25 Net Discharge (Spm) 30 35 40 Vol of Transport Line Before Valve 1.6 PF3005 High Head Effluent Pump 30 GPM, 1/2HP 1151230V 10 6OHz,200V 30 60Hz PF3007 High Head Effluent Pump 30 GPM, 3/4HP 230V 1@ 60H2,2001460V 3@ 6QHz PF3010 High Head Effluent Pump 30 GPM, 1HP 230V 1 A 60Hz, 200/460V 3g 60Hz PF3015 High Head Effluent Pump 30 GPM, 1-1l2HP 23oY 16 60H2,20012301460v 30 60Hz Vol ol Transport Line After Valve Vol of Manifold Vol of Laterals per Zone Total Vol Before Valve Total Vol After Valve 2.5 0.6 10.5 1.6 13.6 uirements 24.4 18.0 gpm fset 1;lr'{f9-Yc \ t\ n Syslem Cunvei - Pump Curve: ' '' PUmp uptrmal Range: operatlng Point O o Design Poinl: ;i tlI'it { I TP1 + r- I I I I N 4 -r' 1z'L/- ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS ARE ACCURATE PROPERTY LINES AND SETBACK D|STANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALED FOR PRINTING ON 1.I'X IT PAPERSCALE: 1 = 50E0" DRAVYINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 05/2112025 /a SllE PL N w1.0 CBO lnc 129 Cains tane Carbondale, Cobrado 81 623 Phone 970-309-5259 carla-oslberg@gmal-6orn Banghart Residence Lot 21, Mountain Springs Ranch Garfi eld County, Colorado ProjectNumber: Clg Dele: OSf21l2D25 Designed by: GBO Reviewed by: KC Dmwnby: DD Slel1 0F4 CBO lnc. 129 Cains Lane cadondde, cob€do 8'l 6?3 Phone 970"309.5259 cada-ostberg@gmail.com { o) 1.5" DIA SCH4O LEVEL MANIFOLD T (MIN 1OlO DRAIN BACK TO PUMP CHAMBER) \\ \ \ 1.5' DIA SCH4O PUMP LINE. ADV MODEL6402AT HIGH POINT ACCESSIBLE AT GRADE oo o (" 15.5' BM 100'= FF 7698.06' 3.BEDROOM RESIDENCE Banghart Residence Lot 21, Mountain Springs Ranch Garndd County, Colorado Proiect Number: C1954 Dete: GSn1nO25 Dram Design€d Rev'rcwed by: DD by. CBO b)': Kc 4" DIA SDR-35 SEWER PIPE wlTH CLEANOUT MIN 2% FALL TO TANK lr INSPECTION PORTAT CORNER OF EACH BED 1UXTGALLON TWOSOMPARTMENT SEPTIC TANK WTH AN EFFLUENT FILTER ON THE OUTLET FOLLOWED BYA sOO.GALLON PUMP CHAMBER wlTH AN ORENCO PUMP PACKAGE. RISERS AND LIDS TO GRADE NOTE: LOCATION OF VVELL HAS NOT BEEN DETERMINED YET- WELL MUSTBE LOCATED AT LEAST 50' FROM SEPTIC TANK AND 1OO' FROM STA LINE FLUSHING VALVE AT END OF EACH TATERAL (2) 10'x 35' PRESSURE D0SED, oVER-EXCAVATED, UNLTNED SAND FILTERS (MrN.3 ASTM G33 coNcRETE SAND) WnH THREE 39" W|DE GEOMAT SHEETS EACH BED TP1+ (3) 1.5" DrA SCH-40 PVC LAIERALS wa? DlAoRtFlcEs FACTNG DowN,3 O-C. COVERED WTTH ORIFICE SHIELDS o(, 99-q N \ tul0.,9/ 3/ey )././ / ,seaoPoSED owTs SCALE:1 =20=0" w2.0 \:/ shd2 0f 4 ffioFsAitDroTRffi msMIMffi 5' Emffi SWEErc ELL FACilG UPWTH AruLV{VENAVIV€ilAffiATGffi NSESTION rcMAT EACH coRffioF 8S r5m$ffircWrcffi[m 1-S dA SCre PVC LAIERAI,SW5A?DAOFffiSFAclT DOWN AT3 O-C. N GEOTIAT lSmsMffiN(mr%oRMKTOTffi) almil @rsrp-sc!q@ {2} 10 x S ffiSJRE.mED, UNE, iiO(ND€D SANO ilTeRS (w tASril rcdCretE Sm)wTllnRE 1-gMsHwcuruwffa DqoilFrcEs (w ffiE sffi) Frcre oowN AT 30.c- TOE OF SLOPE TYRG NIO HIISFE spm.mFmn$Er! NSEMrcRTATBEGNOFAGffi SUFilmNoTam RC€Rvre {ilffimE f msm-ssMR (un 2% sLoPE TO TSK) FIISHED GSD€ IOTM ACTTA UT ETI\rrc FNISHED GruE 24" MtN_ ORsmFG aEDOb6 3" MIN_ 8'MtN_ A IRE}{CH DEIE\rr-- @%.0.*.@m UEffiffi4N treN@sie:u UPSLOPE TG lruOETG scnfirY BoTTo*t oFffimre w3.0 CBO lnc- 129 Cains Lane Carbondale, Cdbrado 81 623 Phone 970.309.5259 carla.ctb€rg@gmal.corn Banghart Residence Lot 21, Mountain Springs Ranctr Garfield Comty, Colorado Project Numbec C1954 Ade: O5n1nO25 Dram bF DD by: CBO by: KC Designed Revieryed Std30F4 DESIGN PROPOSED 3-BEDROOM RESIDENCE (75 GPD x 2 PERSONS/BEDROOM x 3 BEDROOMS) WASTEWATER FLOW = 450 GPD USE 1OOO GALLON, TWO.COMPARTMENT SEPTIC TANK FOLLOWED BY A sOO-GALLON, SINGLE-COMPARTMENT PUMP CHAMBER WITH AN ORENCO PUMPING SYSTEM SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.65 GAU SF CALCULATED STA = CULTAR = 450 / 0.65 = 692 SF SLIPON F/C DO NOT GLUE 4" DIA INSPECNOil PIPE SOIL PROFILE TEST PTT NO. 1 STATOWATER COTJRSE 50'nla STATO WELL 100'not ddled STATO HOUSE 20'53' SEPT|C TAI{K TO WATER COURSE 50'nJa SEPTIC TANK TO WELL str not ddled HOUSETO SEPTICTN{K m' OWTS COMPONENTS AND PHYSICAL FEATURES MINIMUM REOUIRED SFTRACK APPROXMATE PROPqSED SETBACK FrSshed Grade '1? Minirum CoB Disbbulim PqF Oif6e O!fice Shidd llalive Sol andrs Spsifiod -0 -l 2 4 -5 -6 I -9l,o MOIST, DARK BROVJN LOAMYTOPSOIL MOIsT, REDDISH BROWN CLAY LOAM AINSPEC1ION PORT DETAIL\rr-?d:# /T FLUSHING VALV€ DETAIL\9,-...---_rr5f,lr FINISHED GRADE DIAHOT-E DRILLED INTOTWO SIOES OF PIPE FORVEMNLATION {BELOWSLTPON CAP) DIAVALVE BOX wlTH SECURED tID DIABALL VALVE DIASCH.4O PVC LONG SI'VEEP gI" ELBOI^' SPRINKLERVALVE BOXATGRADE 1_5' DIA SCH-40 PVC LATERAL STA MEDIA GROUNDWATER ENIERING TEST PIT ON UPHIT SIDE AT AI'PROXIi{ATELY 1+OOT BELOW GRADE Fuur EFcUo /?\GEOMAT SECIIO'I\y LEGEND Frq bpsof f,X *r*. 30'OI,AMEIER PVC RISER FROM PUMPING DISTR|BUNNG VALVE ASSEMBLY ,o /,*"r*r..r"","n xf^H-'E?'}^ffiJ3- DIASCH.4O .aSolLS LOG PVC INLETAND OUTLETS A AUTOI'AIIC DSIRIBU'IING\91-nF@ VAL\E DETAIL w4_0 CBO lnc. 129 Cains lane Carbondale, Colorado 81623 Phme 970-309-5259 €da"ctberg@gmail€rn Banghart Residence Lot 21, Mouniain Springs Rancfi Garfield County, Colorado ProlectNumber: C1954 Designed blc CBO Reviewed b]4 KC Drawnb\n DD tu: OSf21l2lJ25 Shet 4 0F 4 Calculatian: OWS - lylound System Design Notes: Desipn, Construction. Operation and Maintenance. dated August, 2020 2. Hightighted Yettow Cells / Red Text indicates User to lnput Data 3. Once catcutation inputs are finatized, ctick ctrl + P to print. l. ther lnput and Calcutated Values ParameterS Vatues Units 15.0 0.35 6.6 Revised: 4t18t2022 I{OTE: lf il -Error w/catc- m€ssqe pops np, this rneans that you have s€hcted certaio \ratu6 that exceed the calculated mlnirnsns or rna,{imu$s Manuatty lnput Units Soit LTAR Linear Loading Rate Sand Fitt Loading Min. upstope sand depth above grade Distribution ril€dia Depth Soit Cover Depth Downslope Upstope Total depth of imported 0.65 2 1 t 1.82 0.69 3 Percent Unitless Unittess Gat. /sq.ft. /d ay Feet Feet Feet Unittess Unittess Feet Parameters Min. Distribution Cetl Lenth fi{in. Distribution Cett Min. Basat Area (sand) Width ,rlin. Downstope mound fitt depth Actuat width to toe of slope Upstope width End Overall tengti Auto-Catcutated Vatues 99-20 Feet Sq- Feet Feet Feet Feet Feet Feet 70.o0 7W 18.86 3.65 31.00 8.28 14.4 101.00 Feet Countp Garfield Date: 6!A2A25 En$neer/Designer: CBO lnc Add'l site information: 68.18181818 692-3{l.76923 18.86 3-67 30.98 8.28 14.51 $eE ru 51,41 (w) m are l, Orawirgs qre nottoscab A Toe of Upstope I I + Site Stope I tlornstoge A Plan View (Ad) 12.'t5381515 $.r).--.} 9.28 18-86 (r) (H*1) 31.98 Section A - A 10. (t-A)8.70 (H*1) 15.51 {K+{} DovrnstoBe Erdent of _-__S!9.81- Cell &tentd Ilistribudon (J+l) (A) 9.28 31"98 + I 18.86 0) - G)qPuhlic,net'" Garfi eld County, Co AccountNumber R070078 ParcelNumber 2L852%OAN9 Acres 35 LandSqFt 0 TaxArea t28 Mlll Levy 63.0774 D ate cr eated: 5 / 2!/ 2O25 Last Data Upload ed: 5/2t/2025 2:11:48 AM PhyslcalAddress 0 GLENWOOD SPRINGS 8T601 OwnerAddress BANGHART,TIMOTHYS 3751 NORTH l92NDAVENUE ELKHORN NE 68022 Overview Legend l-[ Parcels Roads Parcel/Account Numbers OwnerName i:, Lakes & Rivers - CountyBoundary Line TotalActualValue $0 Last2Sales Date Price !2/9/2024 $1,225,000 9/t2/2024 $S8O,OOO Develooed bvtil SCHNEIDER CEO6FATIAL 5121125,12:36 PM Summary Account Parcel Prop€rty Address l.egal Descrlptlon Acres Land SqFt Tax Area Mllltew SubdMsion View Map Owner BANGHART. TIMOTHY S 3751 NORTH l92NDAVENUE ELKHORN NE 68022 Land UnltType Square Feet Acres qPublio.net - Garfield County, CO - Property Record Card: R070078 Garfield County, CO R070078 278529300LO9 ,GLENWOODSPRINGS,CO 81601 Sectlonr 29Townshlp:6 Range:89ATR lN SWAKALOT 21 MOUNTAIN SPRINGS RANCH 35.139 0 128 630770 Map 3s AC TO Lfi 100 AC - 0550 (VACANT LAND) 0 35.13 ActualValues TaxYear 2025 2024 2023 2022 m2t i::::::r'ffi:ar:3:*::5=:ffi:;'i:.:5*:ffi;;=-;--;ffi;ffi1K"jw :r:::gim: ActuatVatue $300,000.00 $235,000.00 $235,000.00 $175,000,00 $175,000,00 Assessed Values Tax Year 2025 2024 2023 2022 2027 Non School Assessed Value $81,000.00 $0.00 $0.00 $o.oo $o.oo School Assessed Value $81,000.00 fo.oo $0.00 $0.00 $o.oo Pre2025AssessedValue $0.00 $65,570.00 $65,570,00 $50,750.00 $50'750.00 *House Blll 248-100tostabllshed a separate assessment rate for school distrlct resldentlal properties, effectlve for the 2025 tax y€ar and beyond. Click here for Asiessor FAQs https;//qpubllc.schneidercorp.com/Appllcation.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD.9447&KeyValue=R070078 'U2 5121125,12:36 PM qPublic.net - Garlield County, CO - Property Record Card: R070078 2023 TaxHlstory Tax Year 2024 2022 2021 Taxes Bllled click here to vlew the tax inform4tion for this parcel on thE Garfield countyTreasurerlLwebsite. $4,t35.96 $3,996.76 $3,459.84 $3,409.04 Transfers Salo Date Deed Tvoe ReceDtion Numb€r Book - Pale Sale Prlce tu9/2024 QUITCLAIM DEED too2419 $0 t2t912024 SPECIALWARRANry DEED t@2418 $1.225.000 llt26t2024 Correctlon (Of Anv Tvoe)1004033 $0 t0/29/2024 AFFIDAVIT LOOI299 $o 9/LU2024 SPECIAL WARMNTY DEED 99?930 $980.000 70/t6/2023 PROTECTIVE COVENANTS 9?0926 $o 4t30/2021 WARRANryDEED 955!J2 $2s0.000 7/6/1994 WARMNryDEED 466117 0909-036X $70,000 5/Ls/1990 WARRANWDEED 4L25s2 Property Related Public Documents Cl ick here to view Propjdyje!e!Cd.-Pd!!9-PgEC!0$!t Photos No data avallabletorthafollowlng moduleet Bulldings, Sketches' r ;r,1 r;tl irr: lllr:ri ;ri tilltr..!. | "U_ss_Prussv*9sley | 9of&?dvasvjtoijse Lastpala !,plsad:-ll?1129?5;LaX-U!AM a779-0052 $47,500 I r'r,rt|i{ lJl ['r;1.,i, ilr, E scr"ry"E,"?Fn 2t2