Loading...
HomeMy WebLinkAboutConditions of PermitcoNDrilo NS OF PERMIT BLCO-04-25-9221 ASTER PLACE CLUBHOUSE AFFORDABLE HOUSING FAM ILY DEVELOPMENT 5 STONE OUARRY ROAD, BATTLEMENT MESA PARCEL N U M BER 2407 1 81 21 OO2 1) THE APPROVED PLANS ARE TO BE ON-SlrE FOR INSPECTIONS. 2) SANTTARY FACTLnES ARE REOUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. RMITS 4) UNDERGROUND UTrLrry LOCATES rS THE RESPONSTBTLTry OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE. 5) DRAINAGE ACROSS PROPERry LINES SHALL NOT EXCEED THAT WHICH EXISTED PRIOR TO GRADING. EXCESS OR CONCENTRATED DRAINAGE SHALL BE CONTAINED ON SITE OR DIRECTED TO AN APPROVED DRAINAGE FACILIry. EROSION OF THE GROUND IN THE AREA OF DISCHARGE SHALL BE PREVENTED BY INSTALLATION OF NON-EROSIVE DOWN DRAINS OR OTHER DEVICES. 6) ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 7') SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE COUNTY PLANNER FOR THE APPLICATION. B) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUM ENTATION OF THE I NSPECTIONS. 9) THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE STATE ELECTRICAL INSPECTOR IS REOUIRED (303)869 3458. PLENSE HNVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. 1O)THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. I I)ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO BACKFILLING. 12)PLEASE PROVTDE SPECTAL TNSPECTTONS REPORTS TO THE BUTLDTNG DEPARTMENT, WELDING AND BOLTING IS MINIMUM. 13)GEOTECHNICAL OBSERVATTON tS REOUTRED WHEN THE EXCAVATTON rS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 2000 PsF. 14)ALL EXTERTOR LtGHTtNG rS TO BE DOWNCAST AND SHTELDED. 1 5)SAFETY GLAZING WILL BE CHECKED DURING THE FRAMING AND FINAL r NSPECTTON. ( r BC 2406.4) 16)A KNOX BOX IS REOUIRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION. 17)IF THE FIRE SPRINKLER SYSTEM REOUIRES A FIRE PUMP. THEN THE UTILITY ROOM THAT HOUSES THE PUMP WILL BE REOUIRED TO BE ONE-F|OUR CONSTRUCTION. (rBC TABLE s08.2.s) 18)THE WALLS SURROUNDTNG THE TOTLET ARE TO BE NON-ABSORBENT FOR A HEIGHT OF 48" AND 2' PAST ON EACH SIDE OF THE TOILET. 19)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, TNCLUDTNG POCKET AND SLTDTNG DOORS. (ANS| A1 17. | - 404.2.6) 20)GRAB BAR BACKTNG rS TO BE rN PLACE FOR ALL TOTLETS AT FRAMTNG INSPECTION. 21)A PASSTNG BLOWER DOOR TEST rS REOUTRED TO BE SUBMTTTED pRtOR TO ISSUING THE CERTIFICATE OF OCCUPANCY. 22)ANY EXPOSED FOAM rS TO BE COVERED W|TH AN TGNTTTON BARRTER OR A THERMAL BARRTER BASED ON LOCAT|ON. (tRC R316) 23)ENGINEER STAMPED TRUSS DRAWINGS ARE REOUIRED TO BE PROVIDED TO THE INSPECTOR AT FRAMING INSPECTION, 24)SLAB EDGE TNSULATTON rS SHOWN ON THE TNSTDE OF THE FOUNDATTON WALLS, PLEASE HAVE AN INSPECTOR VERIFY PRIOR TO COVERING. 25)THE SHADE STRUCTURE IS DEFERRED TO A VENDOR, RCP STRUCTURES, PLEASE SUBMIT ENGINEER STAMPED DRAWINGS FOR REVIEW PRIOR TO ERECTION. 26)IT APPEARS THAT WINDOWS B AND D MAY NEED TO BE SAFETY GLAZED DEPENDING IS THE PANES WILL BE OVER 9 SO. FT. 27)RESTROOM 5 WrLL REQUTRE A RTGHT-HAND FLUSH MODEL WATER CLOSET. 28)GYPSUM IS BEING USED FOR LATERAL BRACING. SEE THE SHEARWALL SCHEDULE AT DRYWALL INSPECTION AND DETAIL 4/55.20 TO THE ROOF SHEATHING BETWEEN TRUSSES. 29)l losr DtB, wt l-1, ts NoT To BE |NSTALLED tN THE EXTERTOR WALL CORNER. 30)THE HEATPUMP WATERHEATER tS TO BE tN A ROOM W|TH A VOLUME OF 700 CUBIC FEET. THERE IS A CONCERN THAT THE VOLUME OF THE ROOM WILL BE LESS THAN THE MANUFACTURER'S REQUIREMENT WITH THE EOUIPMENT AND DUCTING IN THE ROOM. LOUVERS OR A DUCTING KIT MAY BE NESSASARY FOR PROPER FUNTION. 31)AN EXTERTOR EX|T LtcHT ts REOUtRED ouTslDE EVERY EXIT DOOR, THE PLANS ONLY INDICATE ONE OVER C104. EMERGENCY LIGHTS ARE REOUIRED OVER C1O1 AND C102.