HomeMy WebLinkAboutEngineer's OWTS Design Plan129 CaINs LANE
CARBoNDALE,CO 4I623
970.309.5259
CARLA.oSTBERG@GMAIL. cOM
sttl>'t' r(r ( :()NlJt rr,'l' l;\(;
April6,2025 Project No. C1947
Patrick Gilson
patrick@korultd.com
Subsurface lnvestigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
TBD Divide Creek Road
Garfield County, Colorado
Patrick,
CBO lnc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 3.812-acre property is located outside of Silt, in an area
where OWTSs and wells are necessary.
Legal Description:Section: 12 Township: 7 Range: 92 LOT 1, JOSEF P. LANGEGGER SUBDIVISION
EXEMPTION, AS PER FINAL AMENDED PLAT RECEPTION NO. 927211.3.812 ACRES
Parcel lD: 24O1 -124-00-262
SITE CONDITIONS
The property is currently undeveloped. A 3-bedroom residence is proposed with a future bedroom
contemplated in the future.
An existing OWTS may exist on the southern portion of the property. An application was made to
Garfield County on September 10, 2020 and is documented under Permit Application Number SEPT-O9-
10-2020. The previous owner had an RV parked on the southern portion of the property and there may
be a septic tank in this area. Any existing OWTS component must be abandoned.
The residence will be served by a private well on the property. The well is located to the south of the
proposed residence. The well is located greater than 5O-feet from the proposed septic tank and greater
than 10O-feet from the proposed soil treatment area (STA).
Divide Creek crosses County Road 31 1 (Divide Creek Road) south of the property and meanders along
the western side of the property. There must be at least S0-feet from any OWTS component to Divide
Creek.
The proposed STA location is located to the east of the proposed residence. The area parallels an
existing driveway (not used as a driveway in the proposed development)and slopes to the west at an
approximate 14% slope towards Divide Creek. The proposed area is vegetated sparse grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
Page2
SUBSURFACE
The subsurface was investigated by Geo Quest, Project No. 24-156 and is documented in a report dated
June 19, 2025 (enclosed).
Geo Quest has classified soils as SoilType 3, Sandy Clay Loam. A pressuredosed, over-excavated,
unlined sand filter with a minimum 2-feet sand filter material (Secondary Sand) is proposed. A long term
acceptance rate (LTAR) of 0.65 gallons per square foot will be used to design the OWTS.
DESIGN SPECIFICATIONS
Any existing O\Af|S component must be property abandoned, if they exist.
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th Bedroom) = 525 GPD
LTAR = 0.65 GPD/SF
525 GPD / 0.65 GPD/SF = 808 SF
(2) 10' x 40.5' pressure-dosed, over-excavated sand filter with min. 2' sand filter material
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 6173.33' has been established as
100' (Finished Floor, Lower Level). CBO lnc. should be notified of any discrepancies or problems with
grade elevations of proposed components during installation of the OWTS.
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions, Minimum grade refers to piping between components.
The 4-inch SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum
2o/o grade to the septic tank.
The system installation will include a minimum 12S0-gallon, two-compartment septic tank with an
Orenco@ Biotube Effluent Filter on the outlet followed by a SOOgallon, single-compartment pump chamber
with an Orenco@ Biotube Pump Vault and an Orenco@ PF3005 pump. We have specified lnfiltrator@
septic tanks that are typically locally available. The floats should be set to dose approximately 85 gallons
each pump cycle, allowing approximately 13 gallons of drain back. The control panel for the pump
must be located within line of sight of the septic tank. An electrician will be responsible for wiring the
pumping system and the contractorwill be responsible for connecting the plumbing. This office should be
contacted for start up of the system to verify its functioning and to perform a squirt test prior to use of the
system.
OWTS Gomponent Minimum Elevation
Primary Tank lnlet lnvert Approximate horizontaldistance 49'l min. 2%fall I
mln.12.25" lall
Automatic Distributing Valve Approximate horizontal distance 125' I min. 1% rise
/ min. 15.625" rise
lnfiltrative Surface Approximate horizontal distance 3' / min. 1o/o fall to
STA / min. 0,375" fall
Page 3
Pu Table
Effluent will be pumped through a 1.S-inch diameter pump line from the pump chamber to an Orenco@
automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1o/o grdde for proper
drain back into the tank after each pump cycle, The ADV must be placed at a high point in the system in an
insulated riser with access from grade. Screened rock must be placed below the ADV to support the ADV
and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance.
Effluent will be pressure dosed to through 1.S-inch diameter distribution lines to two 10' x 40.5' bed. A
minimum of 2-feet of sand filter material will be installed in the over-excavated footprints. Sand filter material
must be clean, coarse sand, all passing a screen having four meshes to the inch. The sand must have an
effective size between 0.15 and 0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting
ASTM 33, for concrete sand, with three percent or less fines passing 200 mesh sieve may be used. A
gradation of the sand media must be submitted to this office prior to obtaining the sand.
Laterals must be 1.SJnches in diameter with 5/32-inch diameter orifices facing down, spaced 3-feet on
center, installed on the GeoMatrM with the filter fabric over the laterals. Laterals should be placed 2-feet
from the edges of the bed with 3.0-feet between the laterals. Laterals will be connected with 1.SJnch
diameter level manifolds. Three 39" wide GeoMatrM sheets must be placed on the 1O-foot wide beds. All
material associated with the GeoMatrM installation must be proprietary products associated with the
GeoMatrM, including orifice shields and geotextile fabric. Manufacturer instructions must be followed
regarding installation of the GeoMatrM.
Each 1.S-inch diameter lateral must end in a sweeping ellfacing up with a ball valve for flushing. Valves
should be placed in a 1O-inch sprinkler box for access. Laterals must be covered by a soil separation
fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There shall be no
cobble-sized (>2.5") or greater rock in final cover over the GeoMatrM. lnspection ports must be placed at
each corner of each bed. Ports may be cut to grade and covered with a valve box for access,
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
Max = 144.25 gal. (525 GPD x
25o/o + 13 qallons drain back)
Min. 67 gal. (13.5 gal x 4) + 13
oallons drain back
Dose Range
Dose Setting 85 gallons/dose 13 gallons drain back (125' I 1.5"
diameter pump line)
6.5" on/off float separationFloat Separation 500 gallon, single-compartment
lnfiltrator@ poly pump chamber
28.5 gallons per minute (GPM)33.4 feet total dynamic head
ffDH)
Pump Criteria
COMPONENT MANUFACTURER MODEL NO.COMMENTS
Septic Tank lnfiltrator@ M-1530-2CP Minimum 1250-gallon,
lwo-compartment poly
septic tank
We have specified a
1 S0}-gallon septic tank
as ft is locallv available
Effluent Filter Orenco@ =ullsize 4" diameter
Page 4
Construction must be according to the jurisdiction's adopted On-Site Wastewater Treatment System
Regulations, the OWTS Permit, and this design.
PERMIT APPLICATION INSTRUCTIONS
An OWTS Permit Apptication must be submitted to Garfield County Environmental Health Department.
https://wu4qarfield-county.com/environmental-healthifilesqcco/sites/16/OWTS-Application-Complete-
Packet-Dec.-2019.pdf. lf the OWTS Permit Application will be submitted with a Building Permit
Application, it should be submitted directly to Garfield County Building Department.
All questions regarding permit submission can be directed to Garfield County Environmental Health
Department, 970-945-6614 x81 50.
INSTALLATION CONTRACTOR
CBO lnc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO lnc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed, CBO lnc. should be notified 48 hours
in advance to observe the installation.
ln an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
Pump Chamber lnfiltrator@ tM-540-1CP 50O-gallon, single-
compartment poly pump
chamber
Pump Orenco@ PF300511 %HP
120 Volt
Biotube ProPak Pump
Packaoe
Orenco@ BPP3ODD Vault, Filter, Control Panel
ldemand dose)
Tank Risers and Lids Orenco@ Double-walled PVC Risers and
Lids (24" diameter)
ADV Orenco@ v64024 1.5" lnlet and Outlets
ADV Riser and Lid Orenco@ Double-walled PVC Risers
and Lids (30" diameter)
Flushing Assembly Orenco@ 1.5" diameter 2) 45" or 90' long sweep only
6 total)
GeoMatrM GeoMatrix Systems,
LLC
39" wide sheets / Orifice
Shieds
243' of GeoMatrM / 78 Orifice
Shields
Page 5
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular inigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additionalwater is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. lf soil conditions encountered are different from conditions
described in report, CBO lnc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Page 6
Please call with questions.
Sincerely,
CBO lnc.
Aa',rtfu
Carla Ostberg, MPH, REHS
K-CRONK P.0.8orr4o
MacA, C()
g7 o. z5o.o y z / kacfi ayla.cmn &@oudoola con
ReviewedBy:
KachaylaR Cron&, PE.
Colorado License No. 61440
6il40{*a
Pump Selection for a Pressurized System - Single Family Residence Project
Gilson Residence
Parameters
300Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Dishibuting Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
Galculations
1.25
125
40
1.50
6402
3
40
1.50
10
6
40
1.50
6
39.5
40
1.50
5132
3
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
feet
002
0)
o,l!
foF
d
G
o,
.9
o
o
E
o
250
150
100
50
PumpData
510 15 20 25
Net Discharge (gpm)
30 35 40
inches
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per zone
% Flow Differential lsULast Orffice
Transport Velocity Before Valve
Transport Velocity After Valve
Frictional Head Losses
0.68
42
28.5
3
0.8
4.5
4.5
gpm
gpm
Yo
fps
fps
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
Pipe Volumes
5.7
5.9
6.5
0.1
0.1
0.1
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
0 0
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
)quirements
28.5
33.4
13.2
0.3
0.6
12.5
13.2
13.5
gals
gals
gals
gals
gals
gals
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1@ 60H2,200V 36 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
23OV 10 60H2, 200/460V 3@ 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1@ 60H2, 200/460V 3@ 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1t2HP
23OV 1A 60H2,2O0l23Ol460V 3@ 60Hz
gpm
feet
====:
J
=:s
t
=i,
t;
I
I
)
I
System Curve: -
Pump Curve: *
Pump Optimal Range: -
Operating Point: O
o
Design Point:
m"SYSTEMS
LINE
4
N
ffi
THE LOCATION OF PROPOSED IMPROVEI\4ENTS SHOWN ARE
NOT THE RESULT OF A PROPERry SURVEY. THE LOCATIONS
ARE APPROXIMATE. IT IS THE HOMEOWNERS' DUTY TO
ENSURE ALL CONSTRUCTION AND IIMPROVEMENT LOCATIONS
ARE ACCUMTE. PROPERry UNES AND SETBACK DISTANCES
SHOULD BE CONRRMED PRIOR TO EXCAVA]ION. SCALED
FOR PRINTING ON 1 1" X 17" PAPER.
SCALE: 1 = 50'=0"(\
DRAWINGS I\4UST BE USED IN
CONJUNCTION WTH DESIGN
LETTER DATED 04106/2025
/i SITE PLAN
l" - S-0"
w1.0I
H
CBO lnc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla.ostberg@gmail.com
w2.0
1
l
I
l
I
/
*
GARAGE
/,
(t4-B
\
l
I
\''*"7
TANK
SEPTIC,
STA
o
Gilson Residence
TBD Divide Creek Road
Garfield County, Colorado
ProjectNumber: C1947 Drawn by:
Reviewed by: KC
DD
Oatei 0410612025
Designed by: CBO
Sh€et 1 0F 4
).I
no.It
ou>-fnI
o€I
6
(
--+
F
6175
()o)Y\
\
\
n--
ir
s
(t
-5o
T'c
trz
F
z
sgn
z
(D
ox-lo{
zx
l.)
(
8;- gE
2f; -;gqdruE
$H Ef;r+ ni >@> n4m--{'-ro>o -r
\
\.k
-\\
\-
m
\T
qt
mtf
in
g
(nor
Fo-m
mr
zT
rg
it
gt
U'o-Ao
!
c)
s
U,Jn
(!cIoz
trzm
-{o
m
-
tI,
mo
-o(f\-o<
-m=>fld-
iF EsIti,;
+o
^N-iir>-(fI\mzir
-uoz
--{
9=9620-nmxmo5
# c,R
szi
=TmY=@
=il81n7I?JM--{e I->onza,m'mm|9cl
e4e
=<qH80
fi-Qo<
Iild-oImm-ia
8<e<S-:'m =ono'UI Fafr,Q-{fi g
ds Ana =TT 1cll dm!-l -a1\.:rL) =FB *o< Fa>a
ao
_--\
t,4<
.\
rz\
m
c;>
DIUIDE
qeqar
&o<o
€
NO
E
ru
ao
rt!
tr
NqII
*>z
Q rto..rc)3.T9 Uq
3 i E s,Yg@d.= d
E-d * 3'ci A- b)
@FS'dE$qE.3 Bboo6
N
f;Ei=d9hE
Ir{Po>-Vtr€Itr8*ng
otlc-.tada€
Et#8H=o9' 4CSr --{ :o>fi*1--11o'- <tAmm=zZ'- 1OO6O5m-ofrlco=3ooT<+
x6=io=RI
I
I
I
70
<_+
ZOsto- o):ng>n
-o.oAa-imi€zm
AA!-o
m
={rorm
zoc--l
\
)Io
u
o
m ut al< \in
^@EHrZrOTi \.m
r.F\9\{\@
ano
@mo,o\o'-o\
-o.O
"s dg g
z o3. )
5 e&r6fo(Dq:sdo; P* d:.i Fl oR;Rf! +a O
0N
!q
o
oo
NoNo
onq
P<.q.s o@
€ts3.
o< ls
"ag 552.31's 00"00'19" E
3o
-to
(2) 10'x 40.5'PRESSURE DOSED,
END EACH LATEML IN A 90'
THREE SHEETS OF GEOMAI
(EACH 39',) ON EACH BED
1.5'DIA SCH.4O PVC PUMP LINE FROM
TANK (MIN. ,1% DRAIN BACK TO PUMP
CHAMBFR)
ADV MODEL 6402 AT HIGH POINT,
ACCESSIBLE AT GRADE
DIA SCH.4O PVC DISTRIBUTION
LINE TO EACH BED
1.5'DIA SCH.4O LEVEL MANIFOLD
1.5" DIA SCH"4O PVC LATERALS W 5i32"
ORIFICES FACING DOWN, 3' O.C.
LATEMLS PLACED ON TOP OF
GEOMAT, UNDER FILTER FABRIC
RNISHED GRADE
SWEEPING ELL FACING UP WTH A
BALL VALVE IN A VALVE BOX
ACCESSIBLE AT GRADE
/iSTA PLAN
\,,-_.-.ffflfrffi
INSPECTION PORI AT EACH
CORNER OF BED
4' DIA SDR-35 SEWER LINE
(MrN 2% SLOPE TO TANK)
SCREENED
OR SAND FOR
BEDDING
/T FLUSHING VAL\E DETAIL\3/-----!!r'ldG
3" MtN.
I'MtN.
/iTRENCH DETAIL\gr____.__-_-.-_ftrffi
FABRIC
SHEILDS1.5" DIA SCH.4O PVC LATEMLS
WTH 5/32" DIA ORIFICES FACING
DOWN,3'O.C., ON GEOMAT
SND ELTERMTERI
'SECONDffiYSND'
EFFECIVE SE r O15.006mm
UNFORMil COEFFOENT <7.0
% ENES PNNG #200 sEGSlO
PORT AT EACH
GRADE
10" OIA VALVE BOX
WTH SECURED LID
1.5' PVC SLIP X MALE
PIPE THREAD
ADAPTER WCAP
T
TOPSOIL COVER
CORNER
NOTE:
3 SHEETS GEOMAT ON EACH BED
OVER-EXCAVATE
APPROX 3'6'BELOW
NATIVE GMDE AND
FILL WTH MIN. 2'SAND
FILTER MATERIAL
INSTALL FLUSHING
VALVE ECCENTRIC TO
CENTER OF VALVE BOX
,1.5" DIA BALL
VALVE
1.5" DtA SCH.40 PVC
LONG SWEEP 90" ELBOW
1.5" DrA SCH-40 PVC
LATERAL
w3.0
/TSTA SECTION\t-Tt'fsd
2'
r r':,
SAND
CBO lnc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla. ostberg@gmail.com
Gilson Residence
TBD Divide Creek Road
Garfi eld County, Colorado
ProjectNumber: C1947
Oalei 0410612025
Drawn by: DD
by: CBO
by: KC
Designed
Reviewed Sh€t 3 0F 4
DESIGN
PROPOSED 4.BEDROOM RESIDENCE
75 GPD X 2 PERSONS/BEDROOM X 3 BEDROOMS + 75 GPD (4th BEDROOM)
WASTEWATER FLOW = 525 cPD
USE MIN, 1250 GALLON, TWO-COMPARTMENT SEPTIC TANK FOLLOWED BY A sOO-GALLON,
SINGLE-COMPARTMENT PUMP CHAMBER
SOIL TREATMENT AREA (STA):
LONG TERM ACCEPTANCE RATE (LTAR) = 0.65 GAL/ SF
CALCULATED STA = Q/LTAR = 525 / 0.65 = 808 SF
30" DIAMETER PVC
RISER
STA TO WATER COURSE 50'
STA TO WELL '100''133'
STA TO HOUSE 10' I 20',10' I 20'
SEPTIC TANK TO WATER COURSE 50'50'
SEPTIC TANK TO WELL 50'220'
HOUSE TO SEPTIC TANK
OWTS COMPONENTS AND
PHYSICAL FEATURES
MINIMUM REOUIRED
SETBACK
APPROXIMATE PROPOSED
SETBACK
Finished Grade
12" Minimum Cover
Distdbution Pipe
Orifice
Orifce Shield
Native Soil and/or
Specified
39"
/A GEOMAT SECI]ON\9'-i6rffidiE
DISTRIBUTING
VALVE ASSEMBLY
SPRINKLER VALVE
BOX AT GMDESLIP-ON PVC
DO NOT GLUE
4'DIA
INSPECTION PIPE
STA
MEDIA
SLIP.ON PVC
DO NOT GLUE
INSULATED
TRACER WIRE
4" DIA
SEWER LINE
FINISHED GRADE
1/4" DIA HOLE DRILLED
INTO TWO SIDES OF PIPE
FOR VENTILATION
(BELOW SLIP ON CAP)
TO TANK
FINISHED GRADE
HOUSE
FROM
PUMPING SYSTEM
/-\ AUTOMATIC DISTRIBUTING\9,-----ftrfr-dffi
PVC INLET AND
OUTLETS
DIA SCH4O
VALVE DETAIL /ACLEANOUT DETAIL\9r--rir6-s3c
w4.0
TEnsmissive
CBO lnc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla,ostberg@gmail.com
Gilson Residence
TBD Divide Creek Road
Garfi eld County, Colorado
Project Number: C1947
Dale: 04106n025
by: CBO
by: KC
DD
Designed
Reviewed
Drawn by:
Shst 4 0F4
GgoGluasr (970! 318-6784
PO Box 1372
Rifle. CO 81050
geoquestco@pm,me
Geo Quest Project No. 24-1-56
Date:6/19/24
Patrick Gilson
Parcel No. 2401L2400262
Lot 1 County Road 311
silt, co 81652
RE: On-site Wastewater Treatment System (OWTS) Soil Evaluation
Dear Mr. Gilson,
Geo Quest was asked to perform a soil evaluation for a proposed OWTS at the property located at Parcel
No. 240112400262 along County Road 311 south of Silt, Colorado. This memo presents the investigation
details and USDA soil type encountered on May 25,2024. This soil evaluation may be used in OWTS de-
sign.
Bulk soil samples were collected from excavations that reached a total depth of 10 feet for classification
of soil within the treatment zone. These samples were reviewed by Geo Quest using the USDA Soil Tex-
ture and Sffucture Method. Generally, the soil on site correlates to a Type 3, Sandy Clay Loam, based on
Table 10-1from the Colorado Department of Public Health and Environment, Regulation No. 43 On-Site
Wastewater Treatment System Regulation. The soil classification is presented below.
Ground water was not encountered in the excavations at the time of the investigatton in the proposed
OWTS area. Neither bedrock nor a limiting layer were encountered within the depths explored. Random
cobbles and/or boulders were encountered during excavation and should be anticipated during construc-
tion.
Soil Treatment Area Long-Term Acceptance Rates by Soil Texture, Soil Structure, Percolation Rate and
Treatment Level
Respectfully submitted,
Kevin E. Dye, P.E.
Principol
Geo Quest, LLC
SoilType USDA SoiI
Texture
USDA Soil
Structure-Type
USDA Soil Structure-
Grade
Treatment Level 1
(MPr)
Treat-
ment
Level 1
3
Sandy Clay-
Loam
Granular 2-Moderate 41,-60 0.35
57r 59
Attachments: Test Pit Location Map
GeoGluwr ts70) s'18-6784
PO Box 1372
Rifle, CO 81650
geoquastco@pm,me
Approximate Test Pit Location map
PROPOSED OWTS LOCATION MAP
Joh No.: 24-155 Appcndix A
App6'dm.ET6
Pit to€lioE
PDpoi.d liom Sh.
GEo Qucsr
iI
Project Number: 24-156
Proiect Name:Gilson CR 311, Silt
Citv, State: Silt County: Garfield
GEo Glugsr
Weather Conditions: Cloudv, Wind, lntermittent Rain
Date Drilled:5-25-24 Time: 4:30 pm
Drill Ris
Sketch of Surface Conditions and Surrounding
Relative Features:
Enqineer: KED
Location: North Excavation Page 1of1
round Water
$o""
Date
rme:
Depth
(fee0
Sample
Type (1)
GPS Coordinates: WGS 84
NO
W"
Elevation: feet
CD
-9
.9
o(u
(,
D(AMPLE: Sandy CLAY FILL, brown-light gray, low plastic, moist, stiff to very
stiff, organics, calcareous, odor
VERY IMPORTANT!! MARK CHANGE IN SOIL IN GRAPHIC LOG
0
1
2
3 SAND, silt, clay, brown, calcareous, dry to moist,
4
5 Few Random cobbles and boulders encountered from
6 4.5 feet to the bottom
7
I
sc
I
10
Bottom of excavation at g feet
II
(1) SPT=Split Spoon, MC=Modified California Barrel, ST=Shelby Tube, CO=Core (Size), GB=Grab/Bulk Sample
Project Number: 24-156
Proiect Name:Gilson CR 311, Silt
Citv, State: Silt County: Garfield
GEO GWEAT
Weather Conditions: Cloudy, Wind, lntermittent Rain
Date Drilled:5-25-24 Time: 3:45 pm
Drill Ris
ketch of Surface Conditions and Surrounding
Relative Features:
Enqineer: KED
Location: South Excavation Page 1of1GPS Coordinates: WGS 84
NO
WO
Elevation: feet
g)oJ
.9
o(E
o
round Water
$dr"
D
Date
Depth
(fee0
Sample
Type (1)
EXAMPLE: Sandy CLAY FILL, brown-light gray, low plastic, moist, stiff to very
stiff, organics, calcareous, odor
VERY IMPORTANT!! MARK CHANGE IN SOIL IN GRAPHIC LOG
0
1
2
3 SAND, silt, clay, brown, calcareous, dry to moist,
Few Random cobbles and boulders encountered from4
5 2.5 feet to the bottom
6
7
8
sc
9
10
Bottom of excavation at 10 feetII
(1) SPT=Split Spoon, MC=Modified California Barrel, ST=Shelby Tube, CO=Core (Size), GB=Grab/Bulk Sample
Application Date
Parcel Number*
Permit Type*
Work Class*
Buildlng Permit Application
0911012020
240112400262
Septic - New
New
Project Name
Project Address*
City*
Block
Lot
Section-Township-Range *
Subdivision
*z,onrng
Applicant / Owner*
Owner Mailing rAddress *
Owner Phone*
Gontractor
Contractor Phone
Representative (Arch, Eng, etc.)*
General Description *
$ite Plan*
Bin #*
Fee Estimation:
TBD CR 311
Lot 1
12-07-92
Josef P. Langegger Sub Exemption
R- Rural
Gary & Leah Shaw
PO Box 923 Silt, CO 81652
s703193675
OWNER
lnstallation of new OWTS system.
r Yes No
PIF
silt
N/A
Estimated Plan Gheck Fee
Estimated Building Permit Fee
Additional Fees
Fee Name
$
{Due today)
$
This Eslimated Permit Fee is based on your estimaled vatoation and is subjeci to change
after plan review.
Fee Type Fee Amount
Septic-New lnstallation
Permit Fee
Total Additional Fees Due:
Estimated Plan Check Fee:
Total Fees Due:
Payments:
Date
09t10t2020
Total Paid:
Set
$ 123.00
$
$ 123.00
(lncludes Plan Check Fee)
Check Number
$ 123.00
Please contact Gary at 970-319-
3675
Pay Type
Credit Card
$ 123.00
Amount Paid
$ 123.00
Special Notes
Permit Number Assignment
Prefix
Number
Monlh *
Year* (z)
Permit Number*
Received By
09
2Q
SEPT
6486
sEPT-09-20-6486
Brooke Winschell
G)qPublic.net'" Garfi eld Cou nty, co
Account
Number
Parcel Number
Acres
Land SqFt
TaxArea
Mill Levy
RO42344
240172400262
4
0
o23
60.7120
Physical O
Address
SILT
OwnerAddress GILSON, PATRICK L &ASHLEY
A
110 B COUNTY ROAD 121
CARBONDALECO 81623
TotalAcl.ual
Value
Overview
Legend
l_l Parcels
Roads
Parcel/Account
Numbers
OwnerName
[, lakes&Rivers
- CountyBoundary
Line
$180,000 Last2Sales
Date Price
6/74/2024 $350,000
70/29/2079 $120,000
81652
Date created: t2/ I8/2O24
Last Data U pload ed: L2/ L8/2O24 t2:3L:.26 PM
Develooed bvti SCHNEIDER
GEO9PATIAL
12/18124,4:03 PM qPublic.net - Garfield County, CO - Property Record Card: R042344
Garfield County, CO
Summary
Account
Parcel
Property
Address
Legal
Description
Acres
Land SqFt
TaxArea
Mill Levy
Subdivision
View Map
Map
RO42344
240r12400262
,srLT,co 81652
Section: 12Township:7 Range:92 LOT l,JOSEF P. TANGEGGER
SUBDIVISION EXEMPTION, AS PER FINAL AMENDED PLAT
RECEPTION NO. 92721.I.3.AL2 ACRES
3.812
0
23
60.7720
Owner
GILSON, PATRICK L & ASHLEYA
110 B COUNTY ROAD L2I
CARBONDALE CO 81623
Land
UnitType 1AC TO VT 5 AC - 0520 (VACANT LAND)
SquareFeet O
Actual Values
Tax Year 2024 2023 2022 2021 20.20
Actual Value $180,000.00 $180,000.00 $110,000.00 $110,000.00 $20,000.00
https://qpublic.schneidercorp.comiApplication.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=1007948883&KeyValue=R042344 112
12118124,4:03 PM qPublic.net - Garfield County, CO - Property Record Card: R0423214
2024 2023 20?2
Assessed Values
TaxYear 2021 2020
Assessed Value
Tax History
TaxYear
$50,220.fi)$50,220.q)
2023
$31,9(x).OO
2022
$31,900.00
2021
$5,800.00
2020
Taxes Billed $3,048.96
Click here to view the tax information for this parcel on the Garfteld Countyiea9uletbryeb$lq
Transfers
Sale Date DeedTvoe Reception Number Book - Page
$2,090.68 $2,357.16 $38e.12
Sale Price
6/14/2024 SPECIALWARRANTY DEED 99705L $3s0,000
6/t4/2024 SUPPLEMENTAL AFFIDAVIT 997050 $o
9t20/20.22 DEATH CERTIFICATE 993305 $o
70/29/2019 SPECIALWARRANry DEED 927504 $120,0oo
4/28/2014 EASEMENT 849919 $o
8/28/20L3 EASEMENT 840875 $o
7/2U2005 GMNTDEED 684437 t736-164 $o
70/LO/2004 DECLAMTION 662069 1-632-745 $o
4/5/2004 Plat 649844 $o
4t5t2004 RESOLUTION 64978s L575-667 $o
3/8/2004 EASEMENT 649796 r575-672 $o
9/rtl2003 AGREEMENT 638036 1526-277 $o
7l2Upa6 WARRANTYDEED 372857 0692-OO02 $295,000
7l13/198r QUITCLAIM DEED 311309 056+OO25 $o
2/25/7980 WARR,ANTYDEED 301967 o544-0343 $o
2/21/t980 AGREEMENT 301821 o54/-OO57 $o
t2/28/t979 WARRANWDEED 300578 0547-0669 $soo,ooo
Plat
Property Related Public Documents
Click here toview Propjgly@
Photos
No data available for thefollowing modules: Buildings, Sketches.
Tlre Garfield tlounty Assessor's Office makes ever-y effori to pi"oduce tlte rnost accuralc
iniormation possible. No warranties, expressed or irnplied ere provided for the data herein. its
use or ifiterf]retatio{r. Data is subject to constant change and its acclracy and ccmpleteness
cannot be guaranieed.
I User PrivaEy Peljgy I GDPBfrivacv Notice
Last DdaUoload: UL I8 /2O24. IO:31:26 AM
927277 $o
Contact Us Developed b'r'
SCHNEIDERotottaila!a
https://qpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=1007948883&KeyYalue=R042344 212