HomeMy WebLinkAboutBlower Door Testretrrr Retrotec rGloud
Quality Assurance Report
Single Direction Multi Point Blower Door Test
PASS Your Result: 1.12 ACHSA $73.26 CFM50 * 60 / 46883 ft')
Tarset < 3 ACH50
Test lnformation
Test Name
Test Date
Export id
Gompany Name
Technician Name
Technician Email
Building lnformation
Address
City
State
ZiplpostalCode
Country
Year Constructed
Elevation
Address Verified?
Building Latitude, Longitude
GPS validation
Estimated Distance From Address
Test Equipment
Fan Model
Fan Serial Number
Pressure Gauge Model
Gauge Serial Number
Envi ronmental Gonditions
P re-test Indoor Temperatu re
P re-test Outdoor Temperature
Wind Speed
Average Barometric Pressure
Test Dimensions
Gonditioned Floor Area
Volume
143 Maroon Dr
2025-04-14 08:29 AM (PDT)
zBUCZ02B
Dexter Diagnostics
Amanda Poindexter
dexterd iag nostics@g mail. com
143 Maroon Dr
Glenwood $prings
co
81601
United States
Not available
6175 ft
Yes
39.500346, -107.31 0792
Tester location not verified
Not available
Retrotec 5000
sFN105365
Retrotec DM32X
502769
68 "F
44 "F
5 MPH
102.5 kPa
4219 ftz
46883 ft3
1
rEtra Rctrotec rCloud
Test Results Summary
Test Type
Flow Reference Pressu re
Time Averaging
Corrected Flow
Air Changes Per Hour
Percent Uncertainty
Gorrelation, r
lntercept
Slope, n
Test Results
Test Data $et 1
Flow Direction
Gauge Location
Single Direction Multi Point Blower Door Test
50 Pa
10 seconds
873.26 cFM @ 50 Pa
'1.118
8.0%
o.977
11.O73
1.1 16
Depressurize
lnside
Baseline initial
Baseline Duration
Average baseline
seconds
-7.28 Pa
-6.45 -6.82 -7.09 -7.29 -7.52 -7.69 -7.73 -7.62 -7.47 -7.12
Measured Pressure (Pa)
Fan Pressure [5000 - 82] (Pa)
Fan Pressure [5000 - 84] (Pa)
Fan Pressure [5000 - B8l (Pa)
1 -23.68
51.63
436.04
o4 -39.24
'176.26
846.63
151.38
Flow FM 3s3.52
89.5
581.42
Measured Pressure (Pa)
Fan Pressure [5000 - 82] (Pa)
Fan Pressure [5000 - 84] (Pa)
Fan Pressure [5000 - 88] (Pa)
44.14 -53.-61.03
Flow CFM
44.73
881.73
59.31
1026.51
72.36
1143.22
final
Baseline Duration
Average baseline
10 seconds
-6.05 Pa
-6.44 -6.5 -6.34 -6.23 -6.12 -5.98 -5.93 -5.86 -5.42
2
retrn Retrotec rGloud
Test Notes
No notes entered
Flow Equation Parameters - Retrotec Calibrated Flow Parameters
Fan Last Calibrated: 2024-09-11
Fan Model Retrotec 5000
Fan Serial Number 5FN105365
Fan Last Calibrated: 2024-09-11
Units Used For Flow Parameters in Equation CFM
Fan pressure (FP) is the measured fan pressure when using a self-referenced fan or when the room pressure is
negative. lf using a fan which is not self-referenced, and the room pressure is positive, fan pressure is calculated
by subtracting the measured room pressure from the absolute value of the fan pressure.
lf PrA is greater than 0 or fan is self-referencing: f,p = lPrBl - PrA
lf PrA is less than 0 or fan is self-referencing: FP = PrB
Flow calculations are not valid if fan pressure is less than either MF or (K2 x lRPl)
FP = fan RP = room
Range
Open
A
B8
N
0.4990
0.5030
o.5270
K
555.2054
290.8751
121.5413
K1
0.0000
0.0000
0.0000
K2
0.3000
0.4000
0.7000
K3
0.0000
0.0000
0.0000
K4
I
1
1
MF
10
20
35
Xflow =FP-RPxKl +K3xFP xK4
Range
B4
82
B1
874
B.47
B.29
B
-0.01530302
-0.00466154
-o.00313712
-0.00095010
-0.0003s905
-0.00014900
c
6.2742
2.7545
1.4891
0.5900
0.2435
0.0920
D
138.42
25.7',\
'to.71
18.00
12.05
4.40
t<2
0.8000
1.0000
1.0000
0.8000
1.0000
0.6000
A
0.0000176573
0.0000025309
0.0000027369
0.0000007960
0.0000002690
0.0000001 1 10
F
0.59
o.92
0.45
0.15
0.09
-0.02
MF
40
50
60
35
50
50
G
50
50
50
25
25
25
flow =x +BxF +X +D x