Loading...
HomeMy WebLinkAboutBlower Door Testretrrr Retrotec rGloud Quality Assurance Report Single Direction Multi Point Blower Door Test PASS Your Result: 1.12 ACHSA $73.26 CFM50 * 60 / 46883 ft') Tarset < 3 ACH50 Test lnformation Test Name Test Date Export id Gompany Name Technician Name Technician Email Building lnformation Address City State ZiplpostalCode Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Envi ronmental Gonditions P re-test Indoor Temperatu re P re-test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Gonditioned Floor Area Volume 143 Maroon Dr 2025-04-14 08:29 AM (PDT) zBUCZ02B Dexter Diagnostics Amanda Poindexter dexterd iag nostics@g mail. com 143 Maroon Dr Glenwood $prings co 81601 United States Not available 6175 ft Yes 39.500346, -107.31 0792 Tester location not verified Not available Retrotec 5000 sFN105365 Retrotec DM32X 502769 68 "F 44 "F 5 MPH 102.5 kPa 4219 ftz 46883 ft3 1 rEtra Rctrotec rCloud Test Results Summary Test Type Flow Reference Pressu re Time Averaging Corrected Flow Air Changes Per Hour Percent Uncertainty Gorrelation, r lntercept Slope, n Test Results Test Data $et 1 Flow Direction Gauge Location Single Direction Multi Point Blower Door Test 50 Pa 10 seconds 873.26 cFM @ 50 Pa '1.118 8.0% o.977 11.O73 1.1 16 Depressurize lnside Baseline initial Baseline Duration Average baseline seconds -7.28 Pa -6.45 -6.82 -7.09 -7.29 -7.52 -7.69 -7.73 -7.62 -7.47 -7.12 Measured Pressure (Pa) Fan Pressure [5000 - 82] (Pa) Fan Pressure [5000 - 84] (Pa) Fan Pressure [5000 - B8l (Pa) 1 -23.68 51.63 436.04 o4 -39.24 '176.26 846.63 151.38 Flow FM 3s3.52 89.5 581.42 Measured Pressure (Pa) Fan Pressure [5000 - 82] (Pa) Fan Pressure [5000 - 84] (Pa) Fan Pressure [5000 - 88] (Pa) 44.14 -53.-61.03 Flow CFM 44.73 881.73 59.31 1026.51 72.36 1143.22 final Baseline Duration Average baseline 10 seconds -6.05 Pa -6.44 -6.5 -6.34 -6.23 -6.12 -5.98 -5.93 -5.86 -5.42 2 retrn Retrotec rGloud Test Notes No notes entered Flow Equation Parameters - Retrotec Calibrated Flow Parameters Fan Last Calibrated: 2024-09-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated: 2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self-referenced fan or when the room pressure is negative. lf using a fan which is not self-referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. lf PrA is greater than 0 or fan is self-referencing: f,p = lPrBl - PrA lf PrA is less than 0 or fan is self-referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x lRPl) FP = fan RP = room Range Open A B8 N 0.4990 0.5030 o.5270 K 555.2054 290.8751 121.5413 K1 0.0000 0.0000 0.0000 K2 0.3000 0.4000 0.7000 K3 0.0000 0.0000 0.0000 K4 I 1 1 MF 10 20 35 Xflow =FP-RPxKl +K3xFP xK4 Range B4 82 B1 874 B.47 B.29 B -0.01530302 -0.00466154 -o.00313712 -0.00095010 -0.0003s905 -0.00014900 c 6.2742 2.7545 1.4891 0.5900 0.2435 0.0920 D 138.42 25.7',\ 'to.71 18.00 12.05 4.40 t<2 0.8000 1.0000 1.0000 0.8000 1.0000 0.6000 A 0.0000176573 0.0000025309 0.0000027369 0.0000007960 0.0000002690 0.0000001 1 10 F 0.59 o.92 0.45 0.15 0.09 -0.02 MF 40 50 60 35 50 50 G 50 50 50 25 25 25 flow =x +BxF +X +D x 3