HomeMy WebLinkAboutEngineer's LetterDRAWN BY:NLD
DATE:06.24.25
NTSSCALE1483 PANORAMA DRIVE
PRO]ECT NAME:
WOOD HEADER SCHEDULE
TITLE:s1.0
s64s0 E
06t24t2025
C)o
/VAL
hD 0t
5ll/P50N A34 RE: NOTES
INTERRUPTED STUD
PENETRATION HEADER
PENETRATION HEADER NAILING
REQUIREI/ENTS, RE: SCHEDULE
KING STUD(S), RE: NOTES
TRIMMER STUD(S), RE:
SCHEDU LE
2X SILLWIND GIRT, RE: NOTES
SIMPS0N A34, RE: NOTES
SILL TRIlvllVER, RE: N0TES
\!\!,
E
iHoO
3g
ot.g E:'-gE:i6 O!oEa',
!c;I OEHE.=
Dll
SPAN
RE: SCHEDULE
WALL PENETRATION
NOTES:
1. THIS DETAIL APPLIES FOR HEADERS THAT ARE NOT CALLED OUT
ON PLAN.
2. NOTIFY ENGINEER OF ANY CONDITIONS THAT DO NOT APPLY TO
THIS TABLE.
3. MAX HEIGHT OF WALL IS 12LO' N4AX,
4. NUMBER OF KING STUDS REQ'D PER SIDE IS HALFTHE NUMBER
OF INTERRUPTED STUDS, ONE STUD IVINIMUM,
5. 0NE 2x SILL PLATE IS ACCEPTABLE Up T0 7'-0". FOR 0PENINGS
GREATER THAN 7'-0" PROVIDE (2)2x SILL PLATES UP T0 10'-0".
6. SIN4PSON A34 REQ'D FROM KING STUD TO T&B PLATE WHEN
OPENING IS GREATER THAN 6'.0 .
7. SI|\4PSON A34 REQ'D ATWINDOW SILL PLATE GREATER THAN
4'-0".
8, NAILING OF BUILT-UP STUD PACKS IS DEFINED IN THE TYPICAT
STUD PACK NAILING DETAIL,
9. PR0VIDE (2)0.148"0x3" NAILS THROUGH SILL WIND GIRT INTO
SILL TRII\4I\4ER AND (2)0.148',0X3'' NAILS THROUGH HEADER
lRII/I\4ER INTO SILL WIND GIRT.
10, ALL A34 NAILING MAY USE O ,748"4fi7?" NAILS, TYP THIS
DETAIL,
TYPICAL HEADER SCHEDULE
SPAN 2x DFL No2 1 3/4" 1.5E tSL 1 3/4" LVr
TRIMMER
STUDS REQ'D
HEADER
NAILING
3'-0"(2)2x6 (2)su2"(2)su?'I (2)0.148"0x3"
4'-0"(2)2xg (2)srl2"(2)slz',1 (2)0.148"0x3"
5'-0"(3)Zx8 (2)s1/2',(2)5117',1 (3)0.148"0x3"
6L0'(3)2x10 (?)t rl4'(3)s v2"I (3)0.148"0x3"
7!0"(3)2x12 (3)1 rl4',(?)1 114 1 (4)0.148"0x3"
8'-0'(3)2x14 (7)e tlz'(?\e rl2"2 (4)0.148"0x3"
9L0"NP (3le Ll?'(?)erl2"2 (s)0.148"0x3"
10'-0"NP (3)e Llz',(3)erft'2 (s)0.148"0x3"
a
aa
o 2025 DBSD Ltd.
S'rBucruRAL DnsIcrl