HomeMy WebLinkAboutConditions of Permit-Addendum0810812024 - ADDENDUM coNDrilo NS OF PERMIT B LRE-04 -24-8609 JANET & RICK ORRISON New Single-family dwelling w/ attached garage includes changing original crawl space to 1,651 sq ft partial unfinished basement 174 Saddleback Rd, Carbondale Aspen Glen, Filing 6, Lot H-35 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018 I NTERNATIONAL ENERGY CONSERVATION CODE (I. E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNIry DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION. 6) OpEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTTON AND PRrOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,500 PSF soil bearing. 7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERTNG FOR BUtLDtNG TNSPECTOR AT TtME OF FRAME INSPECTION, 8) BLOWER DOOR TEST rS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFTELD COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 9) A LOT TMPROVEMENT CERTTFTCATE, SEALED BY A COLORADO LICENSED SURVEYOR, rS REOUTRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK REOUIREMENTS / BUILDING ENVELOPE. 10) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSTONAL LTCENSED SURVEYOR, rS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD COUNry'S 25-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE. 1 1) PRESCR|PTVE PATH USrNG 2018 |ECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME DESIGN. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET. 1 2) BUTLDER / MECHANTCAL CONTRACTOR ADVISED TO PREPARE REVTSED MANUAL J REPORT DOCUMENTS TO CAPTURE THE NOW 1,651 SO FT UNFINISHED BASEMENT (FORMER CRAWT SPACE). SHALL SUBMIT REVISED MANUAL J REPORT TO GARFIELD COUNTY BUITDING INSPECTOR AT ROUGH-IN MECHANICAL / VENT INSPECTIONS. 13) el8l2o24 REVTSED TOWER LEVEL FLOOR PLANS TNCREASE THE PROPOSED BUTLDING TOTAT'FIRE AREA'TO 7,585 50 FT. FIRE SPRINKLER PERMIT, SPRINKLER PLAN REVIEW, ROUGH. IN AND FINAL FIRE SPRINKLER INSPECTION(S) HANDLED BY CARBONDALE & RURAL FIRE PROTECTION DISTRICT. CONTACT FIRE MASHAL, KARLOLIVER (97O)404.9959 OR koliver@carbondalefire.orq $ '{a t$ \r N