HomeMy WebLinkAboutConditions of Permit-Addendum0810812024 - ADDENDUM
coNDrilo NS OF PERMIT
B LRE-04 -24-8609
JANET & RICK ORRISON
New Single-family dwelling w/ attached garage
includes changing original crawl space to
1,651 sq ft partial unfinished basement
174 Saddleback Rd, Carbondale
Aspen Glen, Filing 6, Lot H-35
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL ENERGY CONSERVATION CODE (I. E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED.
5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNIry DEVELOPMENT WEBSITE FOR
ADDITIONAL I NFORMATION.
6) OpEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTTON AND PRrOR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,500 PSF soil bearing.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERTNG FOR BUtLDtNG TNSPECTOR AT TtME OF
FRAME INSPECTION,
8) BLOWER DOOR TEST rS REOU|RED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFTELD
COUNTY COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
9) A LOT TMPROVEMENT CERTTFTCATE, SEALED BY A COLORADO LICENSED SURVEYOR, rS REOUTRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK
REOUIREMENTS / BUILDING ENVELOPE.
10) AN ELEVATTON SURVEY, SEALED BY A COLORADO PROFESSTONAL LTCENSED SURVEYOR, rS
REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS-BUILT ROOFS COMPLY WITH GARFIELD
COUNry'S 25-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE.
1 1) PRESCR|PTVE PATH USrNG 2018 |ECC TABLE R402.1.2 HAS BEEN CHOSEN FOR ENERGY
COMPLIANCE OF THIS HOME DESIGN. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL
VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET.
1 2) BUTLDER / MECHANTCAL CONTRACTOR ADVISED TO PREPARE REVTSED MANUAL J REPORT
DOCUMENTS TO CAPTURE THE NOW 1,651 SO FT UNFINISHED BASEMENT (FORMER CRAWT
SPACE). SHALL SUBMIT REVISED MANUAL J REPORT TO GARFIELD COUNTY BUITDING
INSPECTOR AT ROUGH-IN MECHANICAL / VENT INSPECTIONS.
13) el8l2o24 REVTSED TOWER LEVEL FLOOR PLANS TNCREASE THE PROPOSED BUTLDING
TOTAT'FIRE AREA'TO 7,585 50 FT. FIRE SPRINKLER PERMIT, SPRINKLER PLAN REVIEW, ROUGH.
IN AND FINAL FIRE SPRINKLER INSPECTION(S) HANDLED BY CARBONDALE & RURAL FIRE
PROTECTION DISTRICT. CONTACT FIRE MASHAL, KARLOLIVER (97O)404.9959 OR