HomeMy WebLinkAboutApplicationGarfield County
Community Development Department
108 8tr'Street, Suite 401
Glenwood Springs, CO 81601
(97Ols4s-8212
www.garfield-countv.com D
jl I lt,
rjN'tr Y
Mi:i..jT
-1
C>{
BUILDING PERMIT
APPLICATION
WPE OF CONSTRUCTION f:n[.]f.trt n ^Commercial/Multi-Family Demol ition: r: i,.', ;,-i I r ri, rilii r,,'i,,
Manufactured Home or Tiny Home (Single or Multi-Level)
I Residential (SF, Duplex or Townhome) srNcle FAMtLy RESIDENcE Reroof
Accessory Dwelling Unit (ADU) - MAXTMUM S|ZE OF 1,200 SeUARE FEET
INVOTVED PARTIES
1042 ARATINA STREET,ANGELES, CA 90042
IVO BILAVER
Emait Address. lvoBCM@GMAIL.COM
Phone:8lbtQ66 4EZ1Property Owner:
Mailing Address:
Phone: ( )
Mailing Address:
Email Address:
contractor: OWNER
Architect: BRAD JORDAN/JORDAN ARCH TTECTURE
Address: po Box 1031, GLENWOOD SPRINGS, CO 91602
Emait Address. BRADJORDANARCH ITECT@GMA| L.COM
6186690
Mailing
Phone:970
Emait Address. STEVE@MOUNTAINTOWNCG.COM
9107766206Phone:Engineer:STEVE EDMISTON/MTCG
Mailing Address:PO BOX 1577, BASALT, CO 81621
Mailing Address:
Email Address:
)Phone:(
PROJECT DETAIIS
Manufactured Home tnstaller: N/A
Describework. NEW SINGLE FAMILY RESIDENCE
JobAddress: 15 FOX PROWL LANE
533 AC
24',-9"Height:# of Floors 2
rot E-33 Btock _
Owne/s Valuation of Work:
Assessor,s parcel Number: 239320301033
sub. ASPEN GLEN
Propefi Size (Sq. Ft. or Acres):
Sq. Ft. of Building:3895
,/Class of Work:New Remodel/Alteration Addition
,/Garage:Attached Detached
PROIECT DETAII.S CONNN UED
Community
Natural Gas Propane Electric Other
Driveway
Permit:
NOTICE
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required information which is correct and accurate to the best of my
Property Owner Print and Sign Date
Permit #:
ISeptic:
IType of Heat:
Authoriw. This application tor a Building Permit must be signed by the Uwner of the property, descrlbed above,
or an authorired agcnt. lf the signature below is not that of the Ownpr, a separate letter of artthority, signed by
the Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (l-) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICAT]ON
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other data
submittcd by mc or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
r --l -^-- ----t- .--:ll ^^--1....,i.L ^-^.,:^i^^- ^f ^^.,consloerallon oTIng tssuallce oTIne nuilotnE rerlllil-, I dEtee tndL r dilu rlry d6,cil15 wilr LUilrpry wrLil Pruvr)rurr) ur oily
federal, state or local law regulating the work and the Garfleld County Building Code, OWTS regulaLiorrs arrd
applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the
structure(s) and facility(ies), described above, are not in compliance with County Regulation(s) or any other
applicable law.
! herohv orant nermiqqinn tn fhc Rr rilriing nlr:isinn to ente!. thp n!.nne!'trJ. rlescr ibed abo.re. to insoect the work. !, r,!, Lvt
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring
the correction of errors in the submittals, if any, discovered after issuance; or {2) stopping construction or use of the
structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
Application, including submittals, and inspections of the work by the Building Division do not constitute an
acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I
acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with
me and my authorized agents, including without limitation my architect designer, engineer and/ or builder.
OFFICIATUSE ONIY I
Special Conditions:
Permit Fee:a^ -.4Ll lT Lt ?t.t
t
Manu. Home Fee:
R,FEBD lz,rozMisc. Fees:Plan 'ryi
Total tu aa '3Hii6"oo ffi;,qARx OWTS No:
-"Ffixc""rr.r/ppd
7-V-ZeBU|TD|NG / PLANNtNG DIV|S|ON :
Signed Approval
'rn/AN,
Date
Gurfield County
BUILDING DEPARTMENT
1"08 Eighth Street, Suite 401, Glenwood Springs, CO 87601
Tel: (970) 94s-8212
PLAN REVIEW CHEc KLIST
Permit No: BLRF -06-e5- ?e 8/
Building lssues Planning/Zoning lssuesbf F-77
rtyLineSetbacks B,€'
luA
OPEN.HOLE SOILS REPORT
subdivision Plat Notes E Of KFP
A're area ltu/zr2l le bf
Septic Permit and Setoacks
Grade/ Topography 30%
Attach Residential'Pla n Review List
Line Plans/ Stamps/ Sticker
ttach Conditions
Energy Compliance Path/Pla n Received
han.gD€
Plan Reviewer to Sign APPlication
Parcel/ Schedule No.
40# Snowload Letter - Manuf' Homes
Soils Report
a
35 ft. Stream Setbacks
Flood Plain
'Bui'itiing 'Heig'ht
Zoning Sign-Off
lmpact Fees
1/ Engineered Foundatio.n
@o,-i,.*,u, * ^,(eyouybaL/ il
/ surveyed site Ptan /'59
Aoolication Siened
,Qaalre-cp
Description & Summarv:
F/-S e8?6 x /0146 s?q//n73
Grade/ TopograPhY 40%
E-7 Planning lssues
Subdivision Plat
r/vb7vo h
cruul e4g? x a4 bb274z
^i qoj/
"I#^
q73 x vz d?t 85b
3t4 *a-r 7,6ab
bAb x lg //s 1ls
9/o 77?,"
Ourl/7 t/4
fEros.oo
ts REQUIRED ATfooTlNG
iNstEcTiax t500 _psr
@;i:;i;ffic*f;rD Rt r 6E>
lahh.A 6"3/azrbfi
boat{t A'L
eiileng
fuov,/*lad
h,*a4e
ir,Un'rJ
#i" dl-
NO NOT
RNAN
z?u9ks
t '' r " t !
t '' ):, rl I\'i.
ENERGY COMPLIANCE SHEET REQUIREMENTS:
Effective June 30, 2O23Please provide details showing how building complies / meets Garfield County's
adopted 2018 IECC and 9!!@!9.,.Zonei!=
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or otherwise identiff any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected material/ R-Value
and U-Values to comply with IRC Table R402J.2o U-Factor Alternative: Provide a ResGheck Reporto Total U-Factor Alternative: Provide softvyare generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.o SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.o Foundation plan showing complete footing and foundation dimensions.r Footing and foundation details speciffing reinforcement and referenced on plans.o Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.o Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold untilthe required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Owner Print:prrlaht Sign:J
700743404
PEGINENTIAI ETIEEA\, ETTI'IENAV
R402.1.1 Vapor retarder. Wall assemblies in the build-
ing thermal envelope shall comply with the vapor retarder
requirements of Section F.702.7 of the International Resi-
dential Code or Section 1404.3 of the International Baild-
ing Code, us upplicublo.
R402.1.2 Insulation and fenestration criteria. The
bulldlng thermal envelope shall meet the requirements ot
Table R402.1.2, based on the climate zone specified in
Chapter 3.
R402.1.3 R-value computation. Insulation material used
in layers, such as framing cavity insulation or continuous
insulation, shall be summed to compute the corresponding
component R-value- The manufacturer's settled R-value
shall be used for blown-in insulation. Computed R-values
shall not include an R-value for other building materials or
air fihrrs- Wrcrc iusulatctl sitliug is used for the purpose of
complying with the continuous insulation requirements of
Tablc. R402.1.2, tl'rc manufacturer's labelctl lt-value lcrr
the insulated siding shall be reduced by R-0.6.
R402.1.4 U-factor alternative. An assembly with a U-fac-
tor equal to or less than that specified in Table R402.1.4
shall be an alternative to theR-value in Table Fi4O2.I.2.
2OI8 INTERNATIONAL ENERGY CONSERVATION CODEO
CopFight I2017ICC- ArL RIGHTS RESERVED. A@ssed byJohD plm (jpld@bonrlalsoftD, Gom of Cabondale) Or&rNmber r1oo743@ on Aug 13, zore ozr3 AM {pD,l) pursuant bl*€ts Agieemcnt frth rCC. No tuih€r r€produdoD or disfiburion aurhodu4 Shgle usr oDly, opthg dd n€Morkilg prohibit€d. AM TNAUTH0MED REpRoDUtrroN oR DISTTBUTIoN
IS A UOIATION OF THE FEDM COPYAICHT Atr .AND Tru UCENSE ACREMM, AND SUBIECT TO CM AND CroM[ PENALTIS TffiREMER
TABLE R492.1.2
INSULATION AND FENESTRANON REQUIREMENTS BY COMPONENT"
CLIMATE
ZONE
FEI,IESTRATION
&FACTOBb
SKYLIGHIT
UfACTOR
GLAZED
FEITIESTRATION
sHGCb'.
CEILING
FVALUE
wooD
FRAIIEWALL
FVALUE
MASS
WALL
,}VALUEI
FLOOR
,TVALUE
BASEIIENTC
WALL
RVALUE
SLABd
RVALUE
& DEPTH
CHAWL
SPACE"
WALL
F.VALUE
NR o.75 o.25 3Lr l3 314 l3 0 ()0
2 0.40 0.65 o-25 38 l3 416 l3 0 o 0
3 0.32 0.55 o.25 38 2O or l3+5'8lt3 l9 5lt3'0 slt3
4 except
Marine 0.32 0-55 0.40 49 20 or l3+5h 8/13 l9 ro lr3 10,2ft r0/r3
5 and
Marine 4
n2n n<<+a ^^- !..dhZU LII I J+J l3l t r 1tr.t)l ty IU, LII rJlr9
6 0.30 0.55 NR 49 20+5'or l3+10"t5121)30r l5/r9 lo,4ft t5lt9
7and8 0.:t(l o.55 NR 49 20+5" or l3+lO"t9l?t 388 t5lt9 10, 4 tt lyll)
NR = Not Required.
For SI: I foot = 304.8 mm.
a. R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or design thickness of theinsulation, the installed R-value ofthe insulation shall be not less than the R-value specified in the table.
b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
Exception: In Climate Zones I through 3, skylights shall be permitted to be excluded from glaz*d fenestration SHGC requirements provided that thc SHGCfor such skylights does not exceed 0.30.
c. "10/l3"meansR-l0continuousinsulationontheinteriororexteriorofthehomeorR-l3cavityinsulationontheinteriorofthebasementwall.
"15/19" means R-I5 continuous insulation on the interior or exterior of the home or R-19 cavity insulation at the interior of thc basement wall. Altematively,compliance wilh "1-5/19" shall be R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the
home-
I d' R 5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation lR-value tbr slabs. as indicated in rhe! table. The slab edge insulation for heated slabs shall not be required to extend below the slab.
e. There are no SHGC requirements in the Marine Zone.f. Basementwallinsulationisnotre4uire.dinwarm-humidlocationsasdefrnedbyFigureR30l.landTableR301.l.
g. Altematively, insulation sufficient to fill the framing cavily and providing not less than an R-value of R-19.
h- The fust value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "l3+-5" means R-13 cavity insulation plus R-5continuous insulation-
I i. MasswallsshallbeinaccordancewithsectionR402-2,5.ThesecondR-valueapplieswheremorethanhalfoftheinsulationisontheinteriorofrhemasswall.
TABLE R402.1.4
EQUIVALENT U+ACTORSA
CLIMATE
ZONE
FEt'IESTRATION
U+ACTOR
SKYLIGHT
U+ACTOR
CEILING
I'.FACTOR
FRATIE
WALL
U-FACTOR
MASSWALL
U+ACTORb
FLOOR
{'FACTOR
BASEMENT
I/VALL
U+ACTOR
CRAWL
SPACEWALL
U+ACTOR
I 0.50 0.75 0.035 0.084 o.197 0.064 0.360 0.477
2 o.40 0.65 0.030 0.084 0.r65 N AAA 0.360 A A1A
3 0.32 0.55 o.030 0.060 0.098 o.047 0.091'0.136
4 except Marine 0.32 0.55 o.Q26 0.060 0.098 0.447 0.059 0.065
5 and Marine 4 0.30 0.55 0.026 0.060 0.082 0.033 0.050 0.055
6 0.30 0.55 0.026 0.045 0.060 0.033 0.050 0.o55
7and8 0,30 0.55 o.0?.6 o.fM5 0.057 o.028 0.050 0.05s
a. Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source.
I b. Mass walls shall be in accordance with Section R402-2.5. Where more than half the insulation is on the interior, the mass wall U-factors shall not exceed O. l7in Climate Zone 1,0.14in ClimateZone2,O.l2inClimate Zone 3, 0.O87 in Climate Zone 4 except Marine,0.065 in Climate Zone 5 and Marine 4, and O.057in Climate Zones 6 throrrgh R
c. In warm-humid locations as defined by Figure R301.1 and Table R301.1, the basemenr wall U-factor shall not exceed 0.360.
R-30
I NTER l'lAIIONAL CODE COUNCIT