HomeMy WebLinkAboutRes-Check ReportGenerated by RESche ck-Web Software
Compl iance Certificate
Project Bilaver Residence
Energy Code:
Location:
Construction Type:
Project Type:
Project SubType:
Orientation:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
Construction Site:
15 Fox Prowl
Carbondale, CO 81623
Ceiling: Flat Ceiling or Scissor Truss
Wall: Wood Frame, 16" o.c.
Orientation: Back
Door: Solid Door (under 50o/o glazing\
Orientation: Back
Door 1: Glass Door (over 507o glazing)
Orientation: Back
Window: Wood Frame
Orientation: Back
2018 IECC
Garfield County, Colorado
Single-family
New Construction
None
Bldg. faces 135 deg. from Nofth
3,895 ft2
L7o/o
s (8499 HDD)
false
false
true
false
false
.sI\
$\\\..\
N
\s
Compliance: l3.O% Better Than Code Maximum UA: 6O7 Your UA: 528
The o/o Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Owner/Agent:
lvo Bilaver
Bilaver Construction & Mgmt.
1042 Aratina Street
Los Angeles, CA 90042
9706186690
ivobcm@gmail.com
2,743
1,161
2I
158
L26
Designer/Contractor:
Brad Jordanjordan architecture inc.
po box 1031
glenwood springs, CO 81602
9706186690
BRADJORDANARCHITECT@GMAIL.C
OM
49.0
20.o
0.0
6.0
0.026
o.042
0.166
0.280
0.280
0.026
0.060
0.300
0.300
0.300
72
36
3
44
35
72
51
6
47
3B
liance: Passes using UA trade-off
Cavity
R-Value
Cont,
R-Value
Prop. Req.
U-Factor U-Factor
Req
UA
Gross Area
Assembly or
Perimeter
Prop
UA
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 1 of10
Cavity
R'Value
Cont.
R-Value
Prop. Req,
U-Factor U-Factor
Prop
UA
Req
UA
Gltrss At ea
Assenr bly
Perimeter
or
Wall L: Wood Frame, 16" o.c.
Orientation: Left side
Window 1: Wood Frame
0r ierrlalirlr: I efl sirle
Wall 2: Wood Frame, L6" o.c.
Or ietrtaliolr: Right side
Window 2: Wood Frame
Orientation: Right side
Wall 3: Wood Frame, 16" o.c.
Orientation: Front
Door 2: Solid Door (under 50% glazing)
Orientation: Front
Window 3: Wood Frame
Orientation: Front
Crawl Wall: Solid Concrete or Masonry
Wall height: 3.0'
Depth below grade: 2.5'
lnsulation depth: 3.0'
BRAD JORDAN/ARCHITECT F"alQt *r*
704
L07
1,415
L50
651
26
126
2,7A3
o.o42
0.280
o-o42
0.280
0.042
0.166
0.280
0.055
0.060
0.300
o.060
0.300
0.060
0.300
0.300
0.055 L2B
20.0 6.0
20.o 6.0
20.0 6.0
19.O 0.0
25
io
5j
42
2T
4
35
t28
I MAY 2025
36
32
76
45
30
8
38
Compllance Stateflreflti The proposed bulldlng deslgn descrlbed here ls conslstent wlth the bulldlng plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
;RE-Scheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REscheck lnspection Checklist.
Name - Title Signature /Date
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 2 ofL0
REScheck Software Version REScheck-Web
lnspection Checkl
II
I
I st
Energy Code: 2018 IECC
Requirements: 0.07o were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Additional Comments/Assumptions:
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Field Verlfied
Value Complies?Comments/AssumptionsPlans Verified
Value
Section#
& Req.lD
Pre-lnspection/Plan Revlew
103.1,
103.2
lPR1llI
I Construction drawings and
documentation demonstrate
:energy code compliance for the
I building envelope. Thermal
i envelope represented on
, construction documents.
pliesIcom
Does Nottr
,ENot Observable
flttot Applicable
103.1,
103.2,
403.7
lPR3l1
1J,,
Construction drawings and
documentation demonstrate
energy code compliance for l
lighting and mechanical systems. .
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
,IComplies
rEooes trtot
:INot Observable
,[ruot npplicable
Heating and cooling equipment is
'sized per ACCA Manual S based
on loads calculated per ACCA
ManualJ or other methods
approved by the code official.
Heating:Btu/hL_
Cooling:Btu/hr_
Heating:Btu/h1_
Cooling:Btu/hq_
DDoes Not
[Not Observable
ENot Applicable
302.1,
7
lPR212
u,
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 3 of1-0
SGctlon*
& RcoJD
Foundaflon rRrpiauonu . ,1*Fryry"Ot 3 f{ll$*H$fq*l*,,,,rumn1 .rr,,[ ormq{c{B/4rou.rpnrrons
R-R-
R-R-
plies
Not
Observable
Not Applicable
402.2.LL
lFo7ll
,g
Unvented crawl space wall
insulation R-value.
See the Envelope Assemblies
table for values.
303.2
IFO8lr
o
Unvented crawl space wall
lnsulatlon lnstalled per
manufacturef s instructions.
iEpoes ruot
i[]ttot observable
itrt'tot
402.2.tL
lFo9l1
o
Unvented crawl space continuous
por retarder installed over
exposed earth, joints overlapped
by 6 in. and sealed, extending at
least 6 in. up and attached to the
wall.
Not
Observable
Applicable
Unvented crawl space wall
insulation depth of burial or
distance from top of wall.
402.2.LL tn.in.
lFo10l1
a in
in
i[Complies
iEoo"t ttot
Not Observable
Not Applicable
See the Envelope Assemblies
table for values.
jA protective covering is installed
ito protect exposed exteriorjinsulation and extends a
lmlnlmum of 6 in. below grade.0 Does Not
Observable
Applicable
Snow- and ice-melting system
controls installed.
@
Not
Observable
Applicable
Additional Comments/Assumptions:
1 High lmpact (ller 1)z Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: Bilaver Residence
Data fllename:
Report date: 02126125
Page 4 of10
Field Verlfled
Value Complies?Comments/Assumptaons
Section
#
& Reo.lD
Framing / Rough-ln lnspection Plans Verlfled
Value
402.7.r,
402.3.1,
402.3.3,
402.5
lFR2ll
it'
See the Envelope AssembliesDoor U-factor table for values.U-U-
U-U-
les
tes
402.L.1,
402.3.4
lFR1ll
,ii
see fhe Envelope Assemblies
table for values.: Glazing U-factor (area-weighted
average).lEooes ruot
,Iwot Observable
,[ruot npplicable
,[ooes ltot
.INot Observable
'trrtrot
303.1.3
lFR4l1
+
U-factors of fenestration prod ucts
are determined in accordance
with the NFRC test procedure or
taken from the default table.
[JComplies ]
EDoes Not
INot Observable
Eruot npplicable
402.4.7.1
lFR2311
\t'.'
Air barrier and thermal barrier
' installed per manufacturer's
instructions.
EComplies
lDoes Not
flNot observable
DNot applicable
402.4.3
lFR2oll
;:j
Fenestration that is not site built
is listed and labeled as meeting
AAMA /WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC
400 that do not exceed code
limits.
IComplies
[Does Not;flNot observable
Ewot Applicable
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate <2.0 cfm
leakage at 75 Pa.
,[Complies ,
flDoes Not ,
[Not Observable '
[ruot appticable
402.4.5
lFR1612
Supply and return ducts in attics
insulated >: R-B where duct is>: 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
;diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.1
lFR1211
t?:,
lDoes Not
[]Not observable
lNot Applicable
403.3.2
lFR13l1
?!,'
Ducts, air handlers and filter
boxes are sealed with
joints/seams compliant with
lnternational Mechanical Code or
lnternational Residential Code, as
IComplies
[Does Not
INot Observable
!Not Applicable
cable.
403.3.5
lFRlsl3
it
EDoes Not
nNot observable
lnot Rpplicable
Building cavities are not used as
ducts or plenums.
Medium (Tier 2)3 (Tier 3)LowI(Tier 1)H 2
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 5 of10
Ducts declared to be within the
conditioned space are either L)
completely within the continuous
air barrier and within the building
thermal envelope, 2) burled
within ceiling insulation in
accoruance with Section
R403.3.6 and the air handler is
located completely wlthln the
continuous air banier anrl within
the building thermal envelope
and the duct leakage is <= L.5
cfm I 100 square feet of
conditioned floor area served by
the duct system, or 3) the ceiling
insulation R-value installed
against and above the insulated
duct >: to the proposed ceiling
insulation R-value, less the R-
value of the insulation on the
.3.7
lFR2813
a EDoes Not
flNot Observable
ENot Applicable
IHVAC piping conveying fluids
;above L05 cF or chilled fluids
jOelow 55 qF are insulated to >R-
j3.
i[ooes not
iEttot observable
iEnot lpplicabte
R-R-
0
Protection of insulation on HVAC
piping.
1
lFR24l1
,g Not
Observable
Applicable
i[ooes tttot
iENot observable
inNot Applicabte
R-R-
g
Hot water pipes are insulated to
>R-3.
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.Not
Observable
Applicable
Additional Comments/Assumptions:
1 High lmpact (Tier 1)z Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 6 of10
All installed insulation is labeled
or the installed R-values
provided.
Not
Observable
Applicable
402.L.L,
402.2.5,
402.2.6
lrN311g
Wall insulation R-value. lf this is a
mass wall with at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
iIComplies
iEooes ruot
iflttot observable
iflruot nppucaote
R-R-See the Envelope Assemblies
table for values.fl Wood
I Mass
fl Steel
I Wood
I MassI Steel
303.2
ltN4l1
Wall insulation is installed per
ma nufacturer's instructions.
Additional Comments/Assumptions:
3 LoW 3)1 (Tier 1)Medium
Project Title: Bilaver Residence
Data filename:
Report date: OU26n5
Page 7 ofL0
Sectlon#
& Req.lD
Final lnspection Provisions rtdtts Ycr ll teu
Value
rteto YerIrIClo
Value Complies?Comments/Assumptions
4O2.I.1, Ceiling insulation R-value.
402.2.7,
402.2.2,
402.2.6
lFr 111
See the Envelope Assemblies
table for values.
R-_
I wood
fl Steel
R-_
I Wood
n Steel
303.1.1.1, Ceiling insulation installed per303.2 manufacturer's instructions.lFl2l1 Blown insulation marked every
300 ftr.
:IComplies
[]Does Not
,ENot Observable
[ruot npplicable
EComplies
[Does Not
INot Observable
INot Applicable
Vented attics with air permeable
insulation include baffle adjacent
to soffit and eave vents that
extends over insulation.
EComplies
nDoes Not
flNot Observable
flNot Rpplicable
402.2.3
lFt22l2
Attic access hatch and door
insulation >R-value of the
adjacent assembly.
Icomplies
[Does Not
nNot Observable
nNot Applicable
R-402.2.4
lFl3l1
Ducts are pressure tested to
determine air leakage with
either: Rough-in test: Total
leakage measured with a
pressure differerilial uf 0.1 irrclr
w.g, across the system including
the manufacturer's air handler
enclosure if installed at time of
. test. Postconstruction test: Total
leakage measured with apressure differentiai of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
ACH 50 ACH 50 :
cfm/100cfm/100ftt-ft2
plies
plies403.3.3
,Ft27lL
lDoes Not
ENot Observable
DNot Applicable
[Does Not
INot Observable
Irvot Rpplicable
402.4.1.2
lFt17l1
Blower door test @ 50 Pa. <=5
ach in Climate Zones 1-2, and<:3 ach in Climate Zones 3-8.
'Duct tightness test result of <:4
cfm/100 ft2 across the system or<:3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
flComplies
lDoes Not
DNot Observable
INot Applicable
cfm/100E-
occur during Frami
403.3.4
lFt4l1
_ cfm/100
ft2
4O3.3.2.L Air handler leakage designated[F124]1 by manufacturer at <:2Yo of
design air flow.
EComplies
[Does Not
ENot Observable
!ruot applicable
Programmable thermostats
installed for control of primary
heating and cooling systems and
initially set by manufacturer to
code specifications.
IComplies
[Does Not
INot Observable
INot npplicable
403.1.1
lFt912
IComplies
[Does Not
INot Observable
Druot nppllcable
403.L.2
trr ruJ-
Heat pump thermostat installed
ort ireai pumps.
Circulating service hot water
systems have automatic or
accessible manual controls.nDoes Not
res403.5.1
lFr11l,
INot Observable
ENot Applicable
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 8 of10
Field Verified
Value Complies?Comments/Assumptions
Section*
& Req.lD
Final lnspection Provisions Plans Verified
Value
All mechanical ventilation system ,
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits per Table
R403.6.1.
lComplies
EDoes Not
INot Observablelnot npplicable
403.6.1
lFr2sl,
Hot water boilers supplying heat
through one- or two-pipe heating
systems have outdoor setback
control to lower boiler water
'temperature based on outdoor
temperature.
'fJcomplies
nDoes Not
[]trtot observable
lNot Applicable
403.2
lFt26l2
system return pipe is a dedicated
return pipe or a cold water supply
pipe. Gravity and thermos-
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
systems
The
403.5.1.1
tFt2Bl2
EComplies
:[Does Not
nNot Observable
ENot Rpplicable
Heated water circulation
have a circulation pump.
Electric heat trace systems
comply with IEEE 515.1 or UL
515. Controls automatically
adjust the energy input to the
heat tracing to maintain the
desired water temperature in the
piping.
IComplies'IDoes Not
flNot Observable
ENot Applicable
403.5.L.2
lFt2912
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
water entering the cold water
pipinq to <: 104eF.
DComplies
[Does Not
ENot Observable
lNot Applicable
403.5.2
lFt3o12
Drain water heat recovery units
tested in accordance with CSA
B55.1. Potable water-side
pressure loss of drain water heat
recovery units < 3 psi for
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
403.5.4
lFr31l,
IComplies
lDoes Not
INot Observable
Eruot Rpplicable
DComplies
EDoes Not
INot observable
Itrtot Rpplicable
404.L
lFt6l1
,9oo/o or more of permanent
fixtures have high efficacy lamps
404.1.1
lFr23l3
!!,
IComplies
[Does Not
INot Observable
INot Applicable
Fuel gas lighting systems have
no continuous pilot light.
IComplies
[Does Not
nNot observable
ENot Rpplicable
Compliance certificate posted.401.3
lFt7lz
Medium et 2)3 (Tier 3)Low1(Tier 1)2
Project Title: Bilaver Residence
Data filename:
Report date: 02126125
Page 9 of10
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Additional Comnrents/Assumntions:
Proiect Title: Bilaver Residence
Data filename:
Report date: OzlTGns
Page 1.0 of1.0
I
I
l 2018 IECG Energy
Efficie n cy Ce rtificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating
Cooling System:_
Water Heater:_
Name:
Comments
26.OO
19,OO
o.oo
49.OO
o.28
o.28
Date:
R-Valuelnsulation Rating
Glass & Door Rating U-Factor SHGC
EfficiencyHeating & Cooling Equipment