Loading...
HomeMy WebLinkAboutOWTS Permit Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 0012 Weeping Willow Lane, Carbondale Parcel No.: _239336319008 Owner Name: Frederico J. Pena Owner Email: fpena@soprisliquor.com Designed By: Sopris Engineering Designer Phone: (970) 704-0311 Contractor: RAM Development Inc. Contractor Email: bobby@ramdev.build Number of Bedrooms: _8_ Minimum Tank Capacity: 2,500-gallon Minimum Absorption: 1,313 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9302______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _07/07/2025____________________ Expiration Date_07/07/2026_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Sopris Engineering, LLC. and design revisions dated July 2, 2025. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new five-bedroom main residence and three-bedroom Accessory Dwelling Unit (ADU). The new OWTS components will consist of a new 1,500-gallon three compartment septic tank on the CDPHE approved list for the main residence and a new 1,500-gallon two compartment septic tank on the CDPHE approved list for the ADU, set level with access to grade. A new screened high-head pump will be housed in the second chamber of the septic tank. The septic tanks shall be anchored according to manufacturer recommendations due to the presence of high ground water. Effluent from the ADU septic tank will be dosed to the third chamber of the main residence tank. The combined effluent from the two structures will be dosed from the third chamber of the main residence tank to 1,320 ft2 of STA. The new STA will consist of a two 12 ft by 55 ft unlined sand filter beds, consisting of at least 2 feet of secondary sand media overlain by perforated distribution laterals placed in GeoMat distribution media. Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 5/32-inch orifices every 2-feet on center facing downwards with orifice shields. Each lateral is to end in a flushing valve at the distal end. The residual head (squirt height) at the end of the system is to be 2.5-feet. The infiltrative surface shall be no deeper than 1-foot below natural grade and final cover will be mounded to reach approximately 1.5ft of soil over the distribution laterals and sloped at a 3:1 ratio from the top of the mound to the native grade. Inspection ports are to be installed at each corner of the bed. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 07/27/2025 Issued By: Garfield County Environmental Health Department Date