HomeMy WebLinkAboutApplicationGurfreld County
RU C €. lV Gbtnmunity Development Department
108 8th Street, Suite 401
jUN X 3 ?.025 Glenwood Springs, co 81601
';;ttlmnffi ,*,H#'-.':]l1"?:-'.fi 1i"..,'
n5
BUILDING PERMIT
APPLICATION
Commercial/Multi-Familv Demolition
Manufactured Home or Tiny Home (Single or Multi-Level)
I Residential (SF, Duplex or Townhome)Reroof
Accessory Dwelling Unit (ADU) - MAXIMUM SIZE OF 1,200 SQUARE FEET
tL
L
rs
t
(o t/
?JO
1647 Co Rd 109, Glenwood Springs, CO 81601-9082 US
Emait Addresr. silveradobuilder@aol.com
970 948-4570
Mailing Address
Phone:contractor: Silverado Builders
Architect: Pinon Sage Landscape Architects Phone:970
Itoz 3MailingAddress: VOO Re>srortrg 6
379-081 6
Email Addres' devin@pinonsage.com
f N,no* €Ncruegewq phon",( e7oDevin Williams 987-4773
850 Vista Hi Dr, Carbondale, CO 81623
Engineer:
Emait Addresr. willow.dne@gmail.com
Mailing Address
Job Address: 380 Equestrian Way, Carbondale, Colorado, 81623
sq. Ft. of Buirding: ltlO fWfW,".* 8t # of Floors
Phone:
239131217A34
0.62
Describe work: Covered Patio Addition
Assessor's Parcel Number
Property Size (Sq. Ft. or Acres)
Manufactured Home lnstaller:
Owner's Valuation of Work:
Mailing Address:
Email Address:
Sub. ASeEN EQUESTRIAN ESTATES suB-Dtv tot E7 Btock 26849
r'Class of Work:New Remodely'Alteration Addition
x Attached DetachedGarage:
P@ }WTS nity
atural Gas Propa ne Electric OtherType of Heat:
Permit f:
Authoritv. ThisapplicationforaBuildingPermitmustbesignedbytheOwneroftheproperty,describedabove,
oranauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedby
the Owner, must be provided with this Application.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multiple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement.
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Division accepts the Application, along with the plans and specifications and other data
submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming completeness
of the submittals and approval of this Application, a Building Permit will be issued granting permission to me, as
Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the Building Division. ln
consideration of the issuance of the Building Permit, I agree that I and my agents will comply with provisions of any
federal, state or local law regulating the work and the Garfield County Building Code, OWTS regulations and
applicable land use regulations (County Regulation(s)). All County development requiring a permit, except for
residential uses, are subject to Article 7 of the Land Use and Development Code. I acknowledge that the Building
Permit may be suspended or revoked, upon notice from the County, if the location, construction or use of the
structure(s) and facility{ies), described above, are not in compliance with County Regulation(s) or any other
applicable law.
lherebygrantpermissiontotheBuildingDivisiontoentertheproperty,describedabove,toinspectthework. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Official from: (1) requiring
the correction of errors in the submittals, ifany, discovered after issuance; or (2) stopping construction or use ofthe
structure(s) or facility(ies) if such is in violation of County Regulation(s) or any other applicable law. Review of this
Application, including submittals, and inspections of the work by the Building Division do not constitute an
acceptance of responsibility or liability by the County of errors, omissions, or discrepancies. As the Owner, I
acknowledge that responsibility for compliance with federal, state and local laws and County Regulations rest with
me and my authorized agents, including without Iimitation my architect designer, engineer andf or builder.
t. t t' t,,,,t..t a' |t,). ",1.. t,
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided the required information which is correct and accurate to the best of my knowledge.( iaq l>r
W4
Special Conditions:
see atba CzND
"firy.'vT "FEr'2,5 Manu. Home Fee:Misc. Fees:Adiusted ValuationlI E 422.da
ffi".ht 'Hv?'as BP No:wigqAg+OWTS No:'*oETq,ot
OCC Group:IRL tonst' rvnt:pa
r flilluSetbacks:
hilirlh 7-q-.u;BUILDING / PLANNING DIVISION :
Signed Approval Date
ENERGY COMPLIANCE SHEET REQUIREMENTS:
Effective June 30, 2023 Please provide details showing how building complies i meets Garfield County's
adopted 20'18 IECC and Glimate Zone 5.
Depict and show outline the structure's building thermal envelope. Outline should clearly show portions
of the building to be conditioned inside the envelope (and label or otherwise identify any areas remaining
unconditioned outside this envelope)
Energy Compliance Plan should further include:
Chosen Energy Compliance Path. Prescriptive: Cross Sections of insulated assemblies including the selected material / R-Value
and U-Values to comply with IRC Table R4O2.1.2. U-Factor Alternative: Provide a ResCheck Report
. Total U-Factor Alternative: Provide software generated submittal design reports and inspection
checklist for any RESNET ERI index or other performance path designs
Air sealing details around openings, pipes, penetrations, joints
Fenestration U-factors
Provide mechanical system design details including proposed efficiency rates, types of equipment, fuel
types, locations
Energy efficient lighting specifications - 90% to be high-efficacy (LED complies)
Manual J Report required for new building structures and new equipment installations.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
. SOILS REPORT - lf the project is located in a subdivision with a final plat requiring site specific
soils investigation report or if Structural plans make a specific reference to a soils report, then a
copy of the soils report is required to submit a building permit application.
. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.
. Footing and foundation details specifying reinforcement and referenced on plans.
. Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.
. Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road lmpact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Owner
Gurfield Coun$t
BUILDING DEPARTMENT
108 Eighth Street, Suite 401, Glenwood Springs, CO 8L607
Tel: (970) 945-8212
PI.^AN REVIE WCHE CKLIST
Oqg-o6-a5-?z?/Permit No:
Building lssues Pl a n ni ng I Zoning lssues
Engineered ;Fou.ndatto.n
riveway Permit
Surveyed Site Plan
Septic Permit and Setbacks
Grade/ Topography 30%
Attach Residentia'l'Pla'n Review List
Subdivision Plat Notes
Property Line Setbacks
-4 35 ft. stream setbacks
Flood Plain
Building'Height
Zoning Sign-Off
Road lmpact.Fees nA nfu'f'/ n'9d+
A/4
/1/1
//
OPENI-HOLE SOI LS RHPORT
IS REQLIIREN AT FOOTING
flN$PECNCIN I6U) PSF
<b,?@5.A
Fire Defrrtment Rqriiew .aexenthanf]-=.
Valuation0eterm ination/ Fees
Grade/ Topography 40%
Planning lssues
Subdivision Plat
Red Line Plans/ Stamps/ Sticker
ttach Conditions
Application Signed
Energy Compliance Path/Pla n Received
Plan Reviewer to Sign APPlication
Parcel/Schedule No.
40# Snowload Letter - Manuf. Homes
Soils Report
Descri & Summ
3% V.ftxz(
octHaar
a//h;r?,,b?
l/zz,*
a//u*/€/burb;7r n/aa,t;n .'