HomeMy WebLinkAboutHigh Strength Bolt Test ReportMONUMENT STEEL � ma's"-INSPECT. Mr. Gus Fillis Daly Capitol Builders PO Box 324 Woody Creek, CO. 81656 Re: 9412 Hwy. 82 Dear Mr. Fillis, 11-13-2023 As requested, structural steel special inspection was conducted per the IBC 2015 Edition - Chapter 17: Structural Tests and Special Inspection and the Garfield County requirements. I arrived on -site at 8:45 AM. I met with Mr. Baldo Olivas to review project requirements and material ready for inspection. High Strength bolting inspection was conducted for the main frame structure according to the on -site drawings supplied by Armstrong Steel Buildings, Inc. I observed all bolts to be a combination of 5/8", 3/4", and 1" ASTM A325 high strength bolts with no washers as per the manufacturers printed instructions. All bolts were checked for tightness with a wrench. All Paying surfaces were observed to be in full contact. Upon completion, I observed all bolts to be compliance with project specifications and the inspection criteria of the American Institute of Steel Construction (RISC) and the Research Council on Structural Connections (RCSC). Anchor bolt inspection was conducted for the main frame structure according to the on -site drawings supplied by Armstrong Steel Buildings, Inc. All anchor bolts were checked for tightness with a wrench. Upon completion, I observed all anchor bolts to be in compliance with project specifications, Monument Steel Inspection, LLC 318.469.2279 PO Box 23388 Glade Park, CO 81523 monumentsteelinspectionllc22@gmail.com This final inspection concludes the high strength bolting of the main frame portion of this project. Respectfully submitted, 4w ' Dan Bricker, CWI AWS CWI #09052051 Monument Steel Inspection Danie B er J CW 0 051 Q 1112024 Monument Steel Inspection, LLC PO Box 23388 Glade Park, CO 81523 318.469.2279 monumentsteelinspectionllc220gmail.com Monument Steel Inspection, LLC. Welding, Mechanical Fastening, and Industrial Adhesive Inspection. P.O.Box 23388 Glade Park, CO. 81523 Phone: 318-469-2279 Email — monumentsteelinspectionllc22(c)_gmail.com TO: Mr. Gus Fillis Daly Capitol Builders, Inc. P.O. Box 324 Woody Creek, CO 81656 Field inspection for 9412 Hwy 82 project 11-13-2023 INVOICE Invoice #: 432 Date: 11-27-2023 QUANTITY DESCRIPTION UNIT PRICE TOTAL 4.5 hrs Travel and inspection time $82.00/hr $369.00 1 hr Report time $82.00/hr $82.00 200 miles Mileage chg. $0.655/mi $131.00 TOTAL DUE ON RECEIPT OF INVOICE $582.00 Make all checks payable to Monument Steel Inspection, LLC. Or Send payment through Venmo @welderbrik If you have any questions concerning this invoice, contact Daniel Bricker, 318-469-2279. Late fees totaling 5% will be accrued after 30 days of non-payment. Additional fees may result after 60 days of non-payment. THANK YOU FOR YOUR BUSINESS!