HomeMy WebLinkAboutRes-Check ReportGenerated by REScheck-Web Software Com pl ia nce Certificate Project 318 Eagle Ridge Residence Energy Code: Location: Construction Type: Project Type: Project SubType: Conditioned Floor Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 |ECC Parachute, Colorado Single-family New Construction None L,837 ttz s (6881 HDD) false false false false false Construction Site Owner/Agent:Designer/Contractor: Compliance: 3,99lo Better Than Code Maximum UA: 152 Your UA: 146 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meetthe minimum energy code insulation R-value and depth requirements. Envelope Assemblies Ceiling: Flat Ceiling or Scissor Truss 1,837 49.0 0.0 0.026 0.026 48 48 Wall: Wood Frame, 1"6" o.c. 1,728 2LO 0.0 0.057 0.060 98 104 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Name - Title Signature Date Compliance: Passes using UA trade-off Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Prop UA Req UAAssembly Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06104125 Page 1 of 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 20L8 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen, For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # & Req.lD Pre-lnspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 lPRlli t-,., Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. !Complies nDoes Not ENot Observable !Not Applicable 103.1, 103.2, 403.7 lPR3ll !!. documentation demonstratq energy code compliance for : lighting and mechanical systems. I Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Construction drawings and mplies nDoes Not nNot Observable nNot Applicable 302.1, 403.7 lPR212 V. Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr Heati ng: Btu/hr_ Cooling: Btu/hr nComplies nDoes Not nNot Observable nNot Applicable Additional Comments/Assumptions: 2 31High lmpact (Tier 1)Medium lm act (Tier 2)Low lm (Tier 3) Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06104125 Page 2 of 9 t6lrgtall€di5Ae6vennE €xterior insulation NotEDoes mrntmuma 6'of belowin.Observableitrwotgmde. 'a system eontrols rDDoea ruot Observable Additional Comn€ntslAgsumptisns: Frojeet Titler 318 Eagle Ridge Residenee Data filename: Rqport da.tet 661a4125 Pege3 of 9 Section # & Req.lD Plans Verified Value Field Verified Value Complies?Framing / Rough-ln Inspection Comments/Assumptions 402.4.r.t lFR23l1 Air barrier and thermal barrier instal led per manufacturer's i nstructions. nComplies lDoes Not nNot Observable nNot Applicable 402.4.3 I FR20]1 1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I,S. 2I A44O or has infiltration rates per NFRC 400 that do not exceed code limits. lComplies nDoes Not ENot Observable !Not Applicable lC-rated recessed lighting fixtures sealed at housingiinterior finish and labeled to indicate =2.0 cfm leakage at 75 Pa. !Complies nDoes Not nNot Observable nNot Applicable 402.4.5 lFR16l2 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. EComplies nDoes Not !Not Observable ENot Applicable 403.3.1 lFR12l1 Ducts, air handlers and filter boxes are sealed with joints/seams compliant with lnternational Mechanical Code or lnternational Residential Code, as applicable. 403.3.2 lFR13l1 403.3.s lFR15l3 ,}. Building cavities are not used as ducts or plenums. nComplies nDoes Not nNot Observable !Not Applicable nComplies nDoes Not nNot Observable ENot Applicable Ducts partially or completely buried in ceiling insulation have an insulation R-value not less than R-8, the sum of the ceiling insulation R-value against and above the top of the duct, and against and below the bottom of the duct, is >= than R-19, excluding the R-value of the duct insulation. nComplies nDoes Not nNot Observable nNot Applicable 403.3.6(1, 2\ lFR26l3 Ducts declared to be within the conditioned space are either 1) completely within the continuous air barrier and within the building thermal envelope, 2) buried within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <= 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >= to the proposed ceiling insulation R-value, less the R- value of the insulation on the 403.3.7 lFR2B13 nComplies nDoes Not nNot Observable !Not Applicable 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06lo4l25 Page 4 of 9 HVAC piping conveying fluids above L05 sF or chilled fluids below 55 sF are insulated to >R- 3. R-R- Not iEttot ooservaote jltrlot npplicable nNot Observable ENot Applicable Complies Does Not 403.4.L lFR24l1 e Protection of insulation on HVAC piping. R-R. Etrjot licable CompliesHot water pipes are insulated to >R-3.lDoes Not nNot Observable Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. lDoes Not nNot Observable nNot Applicable res Additional Comments/Assumptions: Medium lm (Tier1ct (Tier L LoW I Project Title: 318 Eagle Ridge Residence Data filename: Report date: OGlO4l25 Page 5 of 9 All installed insulation is labeled or the installed R-values provided.nNot Observable !Not Applicable Complies Does Not Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_ fl Wood fl Mass fl Steel R- nnn Wooa Mass Steel ENot Observable I ENot epplicable 2.6 res nDoes Not 402.L.L, 402.2.5, ltN3l1g iSee the Envelope Assemblies ',table for values. Wall insulation is installed per manufacturer's instructions.ltN4l1 2 flDoes Not ENot Observable nruot a icable plies Additional Comments/Assumptions: 1 ct (Tier L)hH (Tier 2)Medium 3 Low lm (Tier 3) Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06104125 Page 6 of 9 Plans Verified Value Field Verified Value Complies? Section # & Req.lD Final Inspection Provisions Comments/Assumptions 402 402 402 402 lFrl .1 .2 .2 .2 l1 1 1 2 6 lComplies EDoes Not nNot Observable !Not Applicable Ceiling insulation R-value R-_ ! Wood ! Steel R-_ ! Wood ! Steel See the Envelope Assemblies table for values. 303.1.1.1, Ceiling insulation installed per 303.2 manufacturer's instructions. IFl2]1 Blown insulation marked every 300 ft'z. lComplies nDoes Not nNot Observable nNot Applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. nComplies nDoes Not !Not Observable nNot Applicable 402.2.3 IFt22l2 Attic access hatch and door insulation >R-value of the adjacent assembly. nComplies nDoes Not !Not Observable nNot Applicable R-R-402.2.4 lFt3l1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. EComplies nDoes Not 'nNot Observable nNot Applicable ACH 50 =ACH 50402.4.r.2 lFr1711 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. cfm/100 cfm/100 ft-ftz-403.3.3 lFt2711 EComplies nDoes Not nNot Observable nNot Applicable Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing lnspection. EComplies EDoes Not nNot Observable nNot Applicable cfm/100 t12 403.3.4 lFl4l1 _ cfm/100 ft2 Complies code cations 403.3.2.r lFt24l1 Air handler leakage designated by manufacturer at <=2Vo of design air flow. 403.1.1 lFt9l2 nComplies nDoes Not nNot Observable ENot Applicable !Does Not []Not Observable nNot Applicable Progra mma ble thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to !Complies EDoes Not []Not Observable nNot Applicable 403.r.2 lFt10l2 Heat pump thermostat installed on heat pumps. Circulating service hot water systems have automatic or accessible manual controls. nComplies nDoes Not !Not Observable nNot Applicable 403,5.1 I Ft11]2 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06lO4l25 Page 7 of 9 Section # & Req.lD Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. nComplies lDoes Not ENot Observable nNot npplicable 403.6.1 lFl25l2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. nComplies nDoes Not nNot Observable nruot Applicable 403.2 lFt2612 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.s.1".1 lFt2812 nComplies nDoes Not ENot Observable nruot npplicable Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. nComplies EDoes Not nNot Observable nNot Applicable 403.5.L.2 lFt2912 Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <= L04aF. nComplies nDoes Not nNot Observable nNot Applicable 403.5.2 lFt30l2 Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFr3112 EComplies nDoes Not !Not Observable nNot Applicable nComplies nDoes Not !Not Observable ENot Applicable 404.r lFt6l1 90o/o or more of Permanent fixtures have high efficacy lamps. 404,L.r lFt23l3 flComplies !Does Not nNot Observable nNot npplicable Fuel gas lighting systems have no continuous pilot light. !Complies nDoes Not nNot Observable nNot Applicable Complia nce certificate posted401.3 lFt712 1 ct (Tier 1)Hi ht 2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3) Project Title: 318 Eagle Ridge Residence Data filename: Report date: 06104125 Page 8 of 9 Manufacturer manuals for mechanical and water heatlng systems have been provided.Not Observable Not Applicable Not Additional CommentslAssumptions: 1)Medium I 3 LowtHigh I Project Title; 3L8 Eagle Ridge Residence Data filename: Report date: A6104125 Page 9 of 9 2018 IECC Energy Effi cie n cy Certifi cate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System: Water Heater: Name: Comments 21.O0 o.oo o.oo 49.OO Date: lnsulation Rating R-Value Glass & Door Rating U-Factor SHGC Heating & Cooling Equipment Efficiency