Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT B LRE-0 5-25-927 2 1, o 3 o ff l=J'L?:""'#1TIi, n n, n,. (with 1,483 sq ft attached garage and 315 sq ft garage storage above) 295 S Alta Mesa Rd, Silt Sierra Vista, Lor2 - 217927101002 1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C,)AND 201B I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) ALL EXTERIOR LIGHTING TO BE DOWNCAST AND SHIELDED. 5) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNry COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I NFORMATION. 6) PROPANE FUEL TYPE SPECIFIED: SEE ATTACHED GUIDE. 7) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG INSPECTTON AND PR|OR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 1,500 PSF soil bearing. Provide compaction report for any structural fill. 8) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUILDING INSPECTOR AT TIME OF FRAME INSPECTION. 9) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL/SIGN.OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPT. 10) 31s SO FT SPACE ABOVE GARAGE OCCUPANCY REVTEWED FOR USE AS GARAGE STORAGE ONLY. DETAILS DEPICT THIS SPACE ACCESSED ONLY FROM SAID GARAGE. ANY FUTURE CHANGE IN USE OR OCCUPANCY SHALL BE SUBJECT TO FUTURE BUILDING, ZONING & LAND USE CODE COMPLIANCE APPROVALS. 1 1 ) BLOWER DOOR TEST IS REOUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFIELD COUNTY COI\4MUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. (SEE STAMP FOR SMALL RESIDENTIAL STRUCTURES ON COVER SHEET SO.1) 12) PRESCRIpTtVE PATH USrNG 2018 rECC TABLE R402.1.2 rS CHOSEN FOR ENERGY COMPLTANCE OF THIS HOME. MANUAL J/S REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET. $ d -{ R S" -\\