Loading...
HomeMy WebLinkAboutContractor ResponseCasfrucrbr wColleen Wirth From: Sent: To: Subject: Mor Storage Sales < sales@morstorage.com > Friday, July 11, 2025 2:20 PM Colleen Wirth RE: BLRE-06 -25-9299 - BIGGS detached garage project UNDER REVIEW Thank you for your response, I am in process of making these changes and wil,l, get them back to you hopeful,l.y sometime next week. ThankYou, eilaa ge& Mor Storage LLC 3010l-70 Business Loop Grand lunction, CO 81504 970-254-0460 FAX 970-254-4694 szo-254-o4a From : Co I leen Wi rth <cwi rth @ga rfieldco u ntyco.gov> Sent: Friday, July 11, 20257:44 AM To: Mor Storage Sales <sales@morstorage.com> subject: RE: BLRE-06-25-9299 - BIGGS detached garage project UNDER REVIEW Hi Ethan / Mor Storage - l've just received GarCo faited to send message for Daniet Biggs I had troubte reading handwriting on the emaiI address provided on our apptication form. Shoutd Daniet wish to receive correspondence, kindty forward as needed. Thanks, CoIteen From: Colleen Wirth Sent: Friday, July L1, 2025 7:33 AM To: danielebiggs@msn.com; sales@morstorage.com;cciei@ sn.com Subject: BLRE-06-25-9299 - BIGGS detached garage project UNDER REVIEW BLRE-06 -25-9299 - BIGGS 3385 CR 31 1 Courtesy Message for BIGGS Project Team: s \ \ N N\d 1 SHEDg BARITSCABII\IS Buitding and zoning comptiance review has commenced for BIGGS detached garage project. QUESTIONS / PLAN CORRECTIONS shall be supptied to Garfietd Gounty before plans examination continues and this buitding permit is issued: 1. PLANS EXAMINER COMMENT: No existing or proposed site elevation detait found on Architectu ral I StructuraI stamped ptan sheets and SITE PLAN submissions. 1.A. Amend SITE PLAN and BUILDING PLANS to show actual elevation data in feet ASL at proposed buitding site. please "ctoud" new information on amended ptan. 2. PLANS EXAMINER COMMENT: Structural design criteria missing from sheets A1 , A2, 44 foundation and/or framing detaits. 2.a. Amend sheets 41 , A2, A4 to inctude assumed soiI bearing capacity for the foundation design. please "cloud" new information. 2.b. Amend sheets 41 , A2, 44 to inctude roof snowtoad design Pf = 40 PSF measured at roof, not ground (presumed 40 PSF for site [ocation tess than 7,000 ft etevation). Garfietd County Builcling Code Requirernents guide attached for future project planning and awareness. pl.ease "cloud" new information. 3. PLANS EXAMINER COMMENT: Sheets A1, A2, A3 and 44 remain 'si[ent' on proposed scope of ptans, if any for plumbing, mechanical and electricaI work within the 900 sq ft detached garage. 3.a. witt any naturatgas pipe, propane pipe, orwater piping be roughed- in to the buitding? lf so, please state in writing. 3.b. Witl any electric, solar or fuet-fired mechanicaI heating equipment or heating apptiances be instatted in the buitding now or in the future? lf so, ptease state in writing. 3.d. Wilt this remain an unheated, 'cold storage' structure in perpetuity? lf so, please provide statement in writing. 2 3.e. ls this structure intended as private use only, detached garage accessory buitding to the main residence, for use by the home occupants? lf so, please confirm by statement in writin$. 3.f. Orwittthe 900 sq ft garage be used for any commercial business operations as a ptace of employment or other mixed uses subjectto other tand use review and approvat(s)? 3.g. Fenestration U-factors on garage and doors is unknown. lnsu[ation R-Vatues provided on the cross-section detaiI of A2 - unfortunately --- does not meet Garfietd County Colorado Ctimate Zone 58 and adopted 2O18lECC minimum requirements for heated residentiaI accessory building structure(s). lf buitding is intended to remain unheated, unconditioned cotd storage garage - then a lessor insutation value is acceptabte. lf, however, per 3.b. responses above this is found to be a heated buitding now/in f uture - then originat buitding design shoutd futty compty today with 2018lECC Tabte R4O2.1 .2 Ctimate Zone 58, R-values and U-factors. ln that instance, AMENDED ptan detaits with amended R- values and missing U-factors are needed for the permit set. 4. PLANS EXAMINER COMMENT: I understand there are other existin$ habitable structures on premises. Looking at the prepared SITE PLAN information, it is a bit unctear if this detached garage is located in ctose proximityto an existing septic tank/ leach fietd / propane tanks in proximity to the new garage. 4.a. What is the approximate distance measured in feet to nearest septic tank (O\Af[S)? 4.b. What is the approximate distance measured in feet to nearest leach fietd area serving an OWTS system, if known? 4.c. ls the current property served by an above ground or below ground propane tank? 4.c.i.lf so, what is the approximate distance from propane tank(s) to the new garage? NEXT ACTION STEPS: Gompile answers and (2) paper copies of ALL CORRECTED PLAN SET PAGES. ResubMit AS ONE COMPREHENSIVE resubmission package to the Garfield County Community 3 Development Department front desk. Submit BLRE-06 -25-9299 BIGGS, attn: Colteen Wirth. Thanks for the effort thus f ar,l look forward to receiving more information and seeing your project move forward to buitding construction. Co[leen Wirth Building Ptans Examiner Garfietd Gounty Community Devetopment 108 Bth Street, Suite 401 Gtenwood Springs, CO 81601 (970) 945-1 377 ext 1 61 0 cwi rt h @g arfi e I dc oultyco. gov Staff email addresses are shifting to end in @garJjeldcountyco.gov However, persona[ names/prefixes on emai[ addresses wit[ remain the same. Ptease update our contact information domain. 4