HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by REScfie ck-Web Software Compliance Ceftificate Project ADAMS Residence Energy Code; Location: Construction Type: Project Type: Project SubType: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 IECC Glenwood Springs, Colorado Single-family New Construction None 3,637 lt2 27o/o s (7313 HDD) true false false false true Compliance: 27.O7o BetterThan Codc Maximum UA: 855 Your UA: 524 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home- Construction Site: Lot 23 Filing 6 203 Nymph Lane Glenwood Springs, CO 81601 Envelope Assemblies Ceiling: Flat Ceiling or Scissor Truss Front Walls: Wood Frame, 24" o.c. Door: Solid Door (under 50% glazing) Door 1: Solid Door (under 50% glazing) Window: Vinyl Frame Left Side Walls: Wood Frame, 24" o.c. Window 1: Vinyl Frame Owner/Agent: Jason Adams Homeowner Lot 23 Filing 6 203 Nymph Lane Glenwood Springs, CO 81601 970-379-0616 jrideadams@hotmail.com Designer/Contractor: STEVEN BACZEK STEVEN BACZEK ARCHITECT 46 Glenmere Circle Reading, MA 01867 7813545839 s.baczek@comcast.net N U {I{ .t N $ 4,000 1,,220 40 17 181 318 725 104 4I T2 5 36 B 25 so.0 19.0 0.0 6.0 0.026 0.042 0.300 0.300 0.200 o.o42 0.200 0.026 0.060 0.300 0.300 0.300 0.060 0.300 ro4 59 12 5 54 L2 38 Compliance: Passes using UA trade-off Cavity R-Value Cont. R-Value Prop. Req. U-Factor U-Factor Gross Area Assembly Perimeter or UA UA Prop. Req 19.0 6.0 Project Title: ADAMS Residence Data filename: Report date: 05113125 Page 1 of10 Gross Area or PerimetFr Cavlty R-Value Cont. R-Value Prop. Req. U-Factor U-Factor' Req UAAssemblyProp UA Right Side Walls; Wood Frame, 24" o.c, Door 2: Solld Uoor (u[d€r 50o/o glazlng] WirrrJuw 2: Vitryl Frrrrrru Rear Walls: Wood Flanle, 24" o.c. Window 3: Vinyl Frame Rear Basement Wall: Wood Frame, 24" o.c. Window 4: Vinyl Frame Second Floor: Wood Frame, 24" o.c. Window 5: Vinyl Frame Second Floor: All-Wood Joist/Truss Floor: Slab-On-Grade (Unheated) lnsulation depth: 4.0' lnsulation position: Fully lnsulated (uniform R-value acrosr perimeter and under slab) Basement Wall: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.0' lnsulation depth: 8.0' Contpliance Statement' The proposed calculations submitted with the permit REscheck Version ; REscheck-Web and application to comply A 3,158 15.0 . The proposed building has been with the mandatory requirements 0.035 0.os0 118 168 meet tlre 2018 IECC requirements in REscheck lnspection Checklist. 311 23 19 861 502 749 307 856 24 768 3,358 19.0 19.0 30.o 0.042 o.300 0,200 o.o42 0.200 0.042 o.200 0.o42 0.200 0.023 0.060 0.300 0,300 0.060 0,300 0.060 0,300 0.060 0.300 0.033 r.9.0 6.0 19.0 6.O 6.0 6.0 13.0 r3,0 1.3,0 designed to 16 7 6 22 151 27 92 50 1 25 000.324 0.360 11 7 4 t-5 100 L9 61 35 5 L8 building design described here is consistent with the building plans, specifications, and other rhJzrDatfl/ / Project Title: ADAMS Resldence Data filename: Roport dotcr 05lLtl25 Pago 2 ofX,0 REScheck Software Version : REScheck-Web lnspection Checklist Energy Code: 2018 IECC Requirements: 0.0olo were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Additional Comments/Assumptions: Section # & Req,lD Pre-lnspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 lPR1ll '!J, Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. EComplies [Does Not [Not Observable INot Applicable 103.1, 103.2, 403.7 lPR311 .u Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. flcomplies DDoes Not ENot Observable DNot Applicable 302.1, 443.7 lPR2l, .tt Heating and cooling equipment is sized perACCA Manual S based on loads calculated per ACCA ManualJ or other methods approved by the code official. Heating: Btu/hr_ Cooling: Btu/hr_ Heating: Btu/hr_ Cooling: Btu/hr EComplies lDoes Not INot Observable Eruot npplicable 2 Medium (Tier 2)3 Low lm (Tier 3)I High lmpact (Tier Project Title: ADAMS Residence Data filename: Report date: 05ll3l25 Page 3 of1.0 Section # & Req.lD Foundation lnspection Plans Verified Value Field Verifled Value Complies?Comments/Assumptions 402.1.2 lFo1ll '!!.' R-_ [] Unheated I Heated R-_ fl Unheated I Heated flComplies lDoes Not INot Observable INot Applicable Slab edge insulation R-value see tfre Envelope Assemblies tabte for values. 402.!.2 lFo3ll t!' EComplies flDoes Not l-lNot Observable flNot Applicable ft ft See the Envelope Assemblies tabte for values. Slab edge insulation depth/length. Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during lnsulation lnspection. Not required in warm-humid locations in Climate Zone 3. EComplies EDoes Not flNot Observable ENot npplicable R- R- 402.1.r lFo4l1 see fhe Envelope Assemblies table for values. R-_ R- 303.2 lFo5l1 tJ,' Conditioned basement wall insulation installed per manufacturer's instructions IComplies [Does Not nNot Observable lNot Applicable 402.2.9 lFo6l1 1t' Conditioned basement wall insulation depth of burial or distance from top of wall. DComplies EDoes Not lNot Observable INot Applicable ft ft See the Envelope Assemblies table for values. 303.2.1 lFo11l, A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. EComplies [Does Not INot observable INot Applicable 403.9 lFo12l, [Jcomplies [Does Not INot Observable []Not Applicable Snow- and ice-melting system controls installed. Additional Comments/Assumptions: 1 lm ct (Tier 1)H 2 Medium I (Tier 2)3 Low lmpact (Tier 3) Project Title: ADAMS Residence Data filename: Report date: o5ll3l25 Page 4 of10 Section # & Req.lD Framing / Rough-ln lnspectaon Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.r 402.3.4 lFRlll ai, IComplies [Does Not flNot Observable LNot Applicable Door U-factor U U-See the Envelope Assemblies table for values. 402.7.L, 402.3.7, 442.3.3, 402.5 lFR2l1 IComplies EDoes Not nNot Observable nNot Applicable U-U-Glazing U-factor (area-weighted average). See the Envelope Assemblies table for values. 303.1.3 lFR4l1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. IComplies [Does Not INot Observable INot Applicable 402.4.r.1 lFR23l1 r.! Air barrier and thermal barrier installed per manufacturer's instructions. lComplies LDoes Not ENot Observable nNot Applicable Fenestration that is not site built is listed and labeled as meeting AAMA AruDMA/CS A 1O1 II,S.2 I A44O or has infiltration rates per NFRC 400 that do not exceed code limits. Not 402.4.3 lFR20lr 1!: 402.4.5 IFR16]' lC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate <2.0 cfm leakage at 75 Pa. nNot Observable ENot Applicable lNot Observable lNot Applicable Complies Does Not Supply and return ducts in attics insulated >: R-B where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. a cable. Not res 403.3.1 lFR12l1 . rrl lComplies EDoes Not INot Observable nNot Applicable 403.3.2 lFR13l1 nNot Observable nNot Applicable Ducts, air handlers and filter boxes are sealed with joints/seams compliant with lnternational Mechanical Code or lnternational Residential Code, as 403.3.s lFR1513 '(. Building cavities are not used as ducts or plenums. INot Observable nNot Applicable 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lm (Tier 3) Project Title: ADAMS Residence Data filename: Report date: 05l'J"3/25 Page 5 of10 Section # & Req.lD Framang / Rough-ln lnspection Plans verified Value Field verified Value Complies?Comments/AssumPtions 403.3.7 lFR28l3 ltJ Ducts declared to be within the conditioned space are either 1) completely within the continuous air barrier and within the building thermal envelope, 2) buried within ceilinq insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is <: 1.5 cfm / 100 square feet of conditioned floor area served by the duct system, or 3) the ceiling insulation R-value installed against and above the insulated duct >: to the proposed ceiling insulation R-value, less the R- value of the insulation on the EDoes Not ENot Observable Lruot npplicable 403.4 lFR1712 it HVAC piping conveying fluids above 105 sF or chilled fluids below 55 sF are insulated to >R- 3. R-R-flComplies EDoes Not INot Observable 'INot Applicable 403.4.1 IFR24]1 u/ Protection of insulation on HVAC piping. tlcomplies [Does Not ENot Observable INot Applicable 403.5.3 lFR18l, v Hot water pipes are insulated to >R-3. R-R-EComplies [Does Not ENot Observable [ruot Applicable 403.6 lFR1912 Automatic or gravity dampers are instailed on all outdoor air intakes and exhausts. [Complies flDoes Not INot Observable flruot Applicable Additional Comments/Assu mptions: H Low lm (Tier 3)2 Medium I (Tier 2)31(Tier 1) Project Title: ADAMS Residence Data filename: Report date: O5ll3l25 Page 6 of10 Section # & Req.lD lnsulation lnspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 ilN1312 IJ All installed insulation is labeled or the installed R-values provided. nComplies [Does Not INot Observable nNot Applicable 402.\.1 402.2.6 lrNlli +j.' Floor insulation R-value.R-_ I Wood I Steel R-_ I Wood n Steel EComplies See the Envelope Assemblies [Does Not table for values' INot Observable INot Applicable 303.2, 402.2.8 ilN211 ,1 Floor insulation installed per manufacturer's instructions and in substantial contact with the underside of the subfloor, or floor framing cavity insulation is in contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. IComplies [Does Not nNot Observable nNot Applicable 402.L.L, 402.2.5, 402.2.6 ltN311 Wall insulation R-value. lf this is a mass wall with at least % of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-R-_ I Wood I Mass n Steel EComplies nDoes Not nNot Observable lNot Applicable See fhe Envelope Assemblies table for values.I Wood I Mass I steel 303.2 ltN4l1 Wall insulation is installed per manufacturer's instructions. EComplies DDoes Not INot Observable INot Applicable Additional Comments/Assumptions: 1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 (Tier 3)Low Project Title: ADAMS Residence Data filename: Report date: O5ll3/25 Page 7 of10 Comments/AssumptionsPlans Verifieci Value Field verified Value Complies? Section # & Req.lD Final lnspection Provisions See the Envelope AssembliesCeiling insulation R-value. table for values. Does Not plies res R-_ [-l Wood I steel R-_ ! wood I steel 402.r.L, 402.2.1, 402.2.2, 402.2.6 lFt1ll 303.1.1.1, Ceiling insulation installed per 303.2 manufacturcr's instructions. lFlzl1 Blown insulation marked every 300 ft'z.nNot Ubservable Ettot Applicable lDoes Not ENot Observable Druot applicable Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. DComplies flDoes Not INot Observable flruot Applicable 402.2.3 lFt22l2 Attic access hatch and door insulation >.R valuc of the adjacent assembly. EComplies [Does Not ENot Observable lNot Applicable R.R-402.2.4 lFt3I Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer's air handler enclosure if installed at time of t€st, Po6tconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.0. across the entire system including the manufacturer's air handler enclosure. ACH 50:ACH 50: cfm/100 cfm/100 ftr-ft2 tes plies 402.4.r.2 lFI17l1 Blower door test @ 50 Pa. <:5 ach in Climate Zones 1-2, and <=3 ach in Clintate Zones 3-8. 403.3.3 lFt2711 nDoes Not INot Observable INot Applicable lDoes Not nNot Observable nNot Applicable Duct tightness test result of <:4 cfm/100 ft2 across the system or <:3 cfnr/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing lnspection. [Does Not INot Observable Itrtot Applicable cfm/100 {t2 403.3.4 lFr4l1 _ cfm/100 ft2 Air handler leakage designated by manufacturer at <:27o of design air flow. flcomplies [Does Not flNot obscrvoble fltrlot icable 403.3.2.1 lFt24l1 Pr ograrnrnable thermostats installed for control of primary heating and coollng systems and initially set by manufacturer to code specifications. [Does Not ENot Observable INot npplicable rcs403.1.1 lFt9l2 es nruot icable 403.t.2 lFr1012 Heat pump thermostat installed on heat pumps.EDoes Not DNot Observable Inot applicable 403.5.1 I Fr11]2 Circulating service hot water systems have automatic or accessible manual controls. EDoes Not INot Observable H lmpact 3 Low lmpact (Tier 3)1 2 Medium lmpact (Tier 2)(Tier 1) Project Title: ADAMS Residence Data filename: Report date: 051L3/25 Page 8 of10 Section # & Req.lD Final lnspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits per Table R403.6.1. EComplies EDoes Not ENot Observable INot Applicable 403.6.1 lFt2s12 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. IComplies EDoes Not ENot Observable flNot Applicable 403.2 lFt2612 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.1. lFt28l2 IComplies EDoes Not flNot Observable Dnot npplicable Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. [Complies EDoes Not ENot Observable nNot npplicable 403.5.1.2 IFt29)2 Demand recirculation water systems have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to <: 104sF. IComplies EDoes Not flNot Observable INot Applicable 403.5.2 lFr30l, Drain water heat recovery units tested in accordance with CSA 855.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 403.5.4 lFt3112 IComplies [Does Not ENot Observable ENot Applicable [Complies [Does Not ENot Observable INot Applicable 404.1 lFt6l1 9oo/o a( more of permanent fixtures have high efficacy Iamps. Compliance certificate posted. 404.r.1 lFt2313 \!,: Fuel gas lighting systems have no continuous pilot light. 401.3 lFt712 DComplies EDoes Not DNot Observable flNot Applicable EComplies lDoes Not [Not Observable ENot Applicable 1 (Tier 1)H 2 Medium (Tier 2)3 (Tier 3)Low Project Title: ADAMS Residence Data filename: Report date: 05/!3125 Page 9 of10 sectlon # & Reo.lD Flnal lnspection Provisions Plans ve.lfled Value Fleld verlf{ed Value Complle3?Comments/Assumptlons 303.3 lFt18l3 i Manufacturer manuals for imechanical and water heating jsystems have been provided. ,[Complies [ooes Not l[Not Observable :ENo[ Applicable Additional Gommcnts/Arumptionrr Medium I (Tier 2)3 (Tier 3)Low1H(Tier Project Title: ADAMS Residence Data filename: Report date: O5lL3l25 Page L0 ofL0 2018 IECC Energy Efficiency Certificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling System:_ Water Heater: Name: Comments 2s.oo 28.OO 13.OO 50.oo o.20 o.30 Date: R-Valuelnsulation Rating Glass & Door Rating U-Factor SHGC EfficiencyHeating & Cooling Equipment