HomeMy WebLinkAboutBlower Door TestResidential Air Infiltration Test Report
Test date:7/16/2025
Project name:Hiatt Residence
Address:1884 County Rd 120
Garfield
Code:2018 IECC
Conditioned volume:24,093 Cubic Feet
Attic:Non-vented
Crawlspace:NA
Garage:excluded
Measured airflow:576 CFM50 Cubic Feet per Minute at 50 Pascal
Temperature; Inside:86
Temperature; Outside:85
Elevation:8,365
Corrected airflow:610 CFM50*Cubic Feet per Minute at 50 Pascal
2018 IECC maximum allowed leakage rate:3.0 ACH50 Air Changes Per Hour at 50 Pascal
Tested air leakage rate:1.5 ACH50 Air Changes Per Hour at 50 Pascal
Test code compliance:PASS
Test notes:
Tests were performed by Chris Taylor; Rated Field Inspector, RFIIN #CY5MPL
* Test results have been corrected for elevation and air density temperature differential.
final blower door test