HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by
Complia
REScheck-Web Software (' .:.*
nce certifi."-tng
,,::,n ,;;;"
Caut;;,^;;i,ilu,iJ ,i;;o|rf
Project Cheney Cabin
Energy Code:
Location:
Construction Type:
Project Type:
Project SubType:
Conditioned Floor Area
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
All Electric
ls Renewable
Has Charger
Has Battery:
Has Heat Pump:
2018 |ECC
Garfield County, Colorado
Single-family
New Construction
None
1,816 ft2
L4o/o
s (8499 HDD)
false
true
false
true
false
Construction Site Owner/Agent:Desig ner/Contractor:
Compliance: O.4olo BetterThan Code Maximum UA: 261 Your UA; 260
The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home'
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the nrinimum energy code insulation R-value and depth requirements.
Envelooe Assemblies
N
{q
a\
N
N
Ceiling: Cathedral Ceiling
Wall: Log
Door 2: Solid Door (under 50% glazing)
Window 2: Vinyl Frame
Wall 1: Log
Window: Vinyl Frame
Wall 2: Log
Door: Glass Door (over 50% glazing)
Window 6: Vinyl Frame
Wall 3: Log
L,228
565
24
107
545
52
328
24
58
57r
0.022
0.087
0,300
0.280
0.087
0.280
0.087
0.300
0.280
0.087
0.026
0.082
0.300
0.300
0.082
0.300
0.082
0.300
0.300
0.082
32
36
7
32
40
16
20
7
t7
44
47.O
0.0
0.0
0.0
0,0
0.0
0.0
27
38
7
30
43
15
0.0
0.0
7
16
47
2t
Passes using UA tr"ade-off
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value
Prop, Req.
U'Factor U-FactorAssembly UA UA
Prop. Req,
0.0
Project Title: Cheney Cabin
Data filename:
Report date: 07116125
Page 1 of 2
Gross Area
or
Perimeter
Cont. Prop. Req.
R-Value U-Factor U-FactorAssemblyR-Value
Cavity
UA UA
Prop. Req.
Window 4: Vinyl Frame
Floor: Slab-On-Grade (Heated)
lnsulation depth: 4.0'
lnsulation position: Fully lnsulated (uniform R-value
across perimeter and under slab)
32 0.280 0.300 9 10
0 0
Compliance Statement.' The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheckVersion : REScheck-Web and to comply with the rnandatory requlrements llsted ln the REscheck lnspectlon Checkllst.
Adam
ame -Signature Date
153 15.0 0.440 0.645
Project Title: Cheney Cabin
Data filename:
Report date: 07116125
Page2 of 2
2018 IEGC Energy
Efficiency Gertificate
Above-Grade Wall
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System
Cooling Syste
Water
Name;
Comments
o.oo
0.00
15,O0
47.OO
o.28
o.30
Date
R-Valuelnsulation Rating
Glass & Eoor Rating tt-Factor SHGC
Heating & Cooling Equiprne,nt Efficianry