Loading...
HomeMy WebLinkAboutResCheck Compliance CertificateGenerated by Complia REScheck-Web Software (' .:.* nce certifi."-tng ,,::,n ,;;;" Caut;;,^;;i,ilu,iJ ,i;;o|rf Project Cheney Cabin Energy Code: Location: Construction Type: Project Type: Project SubType: Conditioned Floor Area Glazing Area Climate Zone: Permit Date: Permit Number: All Electric ls Renewable Has Charger Has Battery: Has Heat Pump: 2018 |ECC Garfield County, Colorado Single-family New Construction None 1,816 ft2 L4o/o s (8499 HDD) false true false true false Construction Site Owner/Agent:Desig ner/Contractor: Compliance: O.4olo BetterThan Code Maximum UA: 261 Your UA; 260 The % Better or Worse Than Code lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home' Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the nrinimum energy code insulation R-value and depth requirements. Envelooe Assemblies N {q a\ N N Ceiling: Cathedral Ceiling Wall: Log Door 2: Solid Door (under 50% glazing) Window 2: Vinyl Frame Wall 1: Log Window: Vinyl Frame Wall 2: Log Door: Glass Door (over 50% glazing) Window 6: Vinyl Frame Wall 3: Log L,228 565 24 107 545 52 328 24 58 57r 0.022 0.087 0,300 0.280 0.087 0.280 0.087 0.300 0.280 0.087 0.026 0.082 0.300 0.300 0.082 0.300 0.082 0.300 0.300 0.082 32 36 7 32 40 16 20 7 t7 44 47.O 0.0 0.0 0.0 0,0 0.0 0.0 27 38 7 30 43 15 0.0 0.0 7 16 47 2t Passes using UA tr"ade-off Gross Area or Perimeter Cavity R-Value Cont. R-Value Prop, Req. U'Factor U-FactorAssembly UA UA Prop. Req, 0.0 Project Title: Cheney Cabin Data filename: Report date: 07116125 Page 1 of 2 Gross Area or Perimeter Cont. Prop. Req. R-Value U-Factor U-FactorAssemblyR-Value Cavity UA UA Prop. Req. Window 4: Vinyl Frame Floor: Slab-On-Grade (Heated) lnsulation depth: 4.0' lnsulation position: Fully lnsulated (uniform R-value across perimeter and under slab) 32 0.280 0.300 9 10 0 0 Compliance Statement.' The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in REScheckVersion : REScheck-Web and to comply with the rnandatory requlrements llsted ln the REscheck lnspectlon Checkllst. Adam ame -Signature Date 153 15.0 0.440 0.645 Project Title: Cheney Cabin Data filename: Report date: 07116125 Page2 of 2 2018 IEGC Energy Efficiency Gertificate Above-Grade Wall Below-Grade Wall Floor Ceiling / Roof Ductwork (unconditioned spaces): Window Door Heating System Cooling Syste Water Name; Comments o.oo 0.00 15,O0 47.OO o.28 o.30 Date R-Valuelnsulation Rating Glass & Eoor Rating tt-Factor SHGC Heating & Cooling Equiprne,nt Efficianry