Loading...
HomeMy WebLinkAboutHVAC Load Short Form# *rightsoff Load Short Form Entire House Monarch HVAC 1-l W9 6'L :?01 fb wbfi Job: 408 Red Cliff Cir Dat@': 512'1125 By: Toby Monger 4 Project lnformation For:Keith Wittenburg, Modfin Design Build 233 Elk Valley Ln, New Castle, CO 81647 Phone: 970-948-31 01 Email : shaggs09@yahoo.com n lnformationDesi clg 87 75 12 H 50 -35 Htg -2 70 72 50 64 lnfiltration Outside db f F) lns ide db (" F) Design TD fF) Daily range lnside humidity (%) Moisture difference (gr/lb) Method Construction quality Fireplaces Simplified Average 1 (Average)$ Make Trade Model AHR|ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat ROOM NAME 96.1 AFUE 80000 Btuh 77000 Btuh 80 'F 1100 cfm 0.025 cfm/Btuh 0.80 in H2O HEATING EQUIPMENT Amana AMANA ACVC960804CN 7368878 COOLING EQUIPMENT Make Amana Trade AMANA Cond MV6SA3610A Coil CAPEA3626C3A+ACVC960804CNB AHR|ref 215490105 Efficiency 9.8 EER2, 16 SEER2 Sensible cooling 23100 Btuh Latent cooling 9900 Btuh Total cooling 33000 Btuh Actual air flow 1100 cfm Air flow factor 0.055 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 1.00 Clg AVF (cfm) .{ \ .s a\ \ s Crawler Bed 1 Bed 2 Mud M Laun Bath H G Bath GCr Guest Liv / Din Kit P 2320 188 174 39 42 58 70 119 49 30 158 539 220 47 0 4111 3273 1057 1 050 0 1 569 0 966 1 053 2739 8984 2724 1 939 0 103 82 26 26 0 39 0 24 26 69 225 68 49 0 1014 2002 118 396 0 834 0 153 76 2953 3089 1037 645 0 56 111 7 22 0 46 0 8 4 163 171 57 36 Boldlitalic values have been manuatty overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Area (tr) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) tl* y"rt*-ttgg.*' *,s n,-ru n"r u niv ersat 20 25 25.o.o2Rsu6 5503 202s-Jul-18 11:05:57 Page 1.€ ,lCCL ...rch\Wrightsofr\408 Red Cliff Cir (Glenwood).rup Calc = MJB Front Door faes: NW 43891 8194 19897 1466 19562 0 11004639 c Entry WC M Bath WC M Bed Entire House Other equip loads Equip. @ 0.92 Latent cooling TOTALS RSM 14 131 17 126 96 202 0 3020 0 4016 3044 4346 0 1873 0 1265 704 3938 0 76 0 101 76 109 0 92 0 70 39 218 1 100 1 100463952085195621 100 Boldlltalic values have been manuatly overrldden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed .l*wglr 2025-Jul-18 11:05:57 Page2Right-Suite@ Universal 2025 25.0.02 RSU65503 ^&,...rch\Wrightsofr\408 R6d Cliff Cir (Glenwood).rup Calc = MJB Front Door faces: NW + wrightsoft-Component Gonstructions Entire House Monarch HVAC Job: Date By: 408 Red Cliff Cir 5t21t25 Toby Monger lnformationPro For:Keith Wittenburg, Modfin Design Build 233 Elk Valley Ln, New Castle, CO 81647 Phone: 970-948-31 01 Email: shaggs09@yahoo.com Desi n Conditions Location: Garfield Co Elevation: Latitude: Outdoor: Rgnl, CO, US 6100 ft 40'N Gooling 87 35 (H ) 59 7.5 lndoor: lndoor temperature ('F) Design TD ('F) Relative humidity (%) Moisture difference (gr/lb) Infiltration: Method Construction quality Fireplaces Heating Simplified Average 1 (Average) Gooling 75 12 50 -34.8 70 72 50 63.8 Dry bulb ('F) Dailyrange ("F) \Abt bulb ('F) Wind speed (mph) Heating -2 15.0 Construction descri ptions Walls 12F-0sw: Frm wall, wd ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 15819-0wc-4: Bg wall, light dry soil, 2"x6" wood int frm, concrete wall, r-19 cav ins, 8" thk Partitions 12E-0sw: Frm wall, 1/2" gyp.bd ext, r-19 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud Windows 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk: 2 glazing, clr outr, air gas, wd frm mat, clr innr,114" gap, 1/8" thk; 6.67 ft head ht 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk: 2 glazing, clr outr, air gas, wd frm mat, clr innr, 1/4" gap, 1/8" thk; '12 ft overhang (1 1 ft window ht, 3 ft sep.); 6.67 ft head ht 0.300 0.300 0.300 0.300 0.300 0.300 2'.t.6 2't.6 21.6 21.6 21.6 21.8 1002 4154 842 2072 8070 345 Or Area ne 572 se 603 sw 419 nw 459 all 2053 ne 176 se 211 sw 176 nw 211 all 772 154 191 Btuhff: U-value BtuhfF-"F 0.300 0.300 lnsul R fl:-" F/Btuh Htg HTM Loss Clg HTM Gain Btuh/tr Btuh Btuh/ff 4.680.065 0.065 0.065 0.065 0.065 o.047 o.047 0.047 0.047 0.047 633 0.068 21.0 21.0 21.0 21.0 21.0 19.0 19.0 19.0 19.0 19.0 4.68 4.68 4.68 4.68 0 0 0 0 0 4.90 2676 2822 1962 2149 9609 0 0 0 0 0 972 3305 670 2009 6955 792 0.32 0.33 0.32 0.32 0.32 0 0 0 0 0 22.3 27.2 27.2 22.3 25,1 9.42 186 196 136 149 667 0 0 0 0 0 19.0 3101 0 0 ne 45 se 153 sw 31 nw 93 all 322 se 37 se all nw n all 0 0 0 0 0 0 0 0 21.6 21,6 1451 1796 3326 4118 9.42 9.42 Doors Door, wd sc type: Door, mtl fbrgl type 0.300 0.300 0.300 Ceilings 18A-38ad: Rf/clg ceiling, asphalt shingles roof mat, frm cons, 1/2" 2320 0.029 gypsum board int fnsh' 12" thkns' r-50 ceil ins Bo*ritaric varues have been manuary overridden 21 21 42 6.3 6.3 6.3 21.6 2't.6 21.6 454 4.86 454 4.86 907 4.86 102 102 204 2.09 4843 0-34 787 A=,sch....rch\Wrightsoft\408 Red Cliff Cir (Glenwood).rup Calc = MJB Front Door faces: NW 38.0 +lf yjlrl-!'g*:Right-Suite@ U niversal 2025 25.O.02 RSU65503 2025-JuF18 I1:05:57 Page 1 Floors 19D-0cstp: Flr floor, frm flr, 12" thkns, tight crul ovr, r-19 wall insul z2A-tpl; Bg floor, light dry soil, on grade depth 2320 258 0.368 0.989 19.0 1.25 2904 0.21 484 0 0 00 0 Boldlitallc values hava been manualty ovefildden {t*rHtg:g.s Right-Sulte@ U niversal 2025 25.o.02 RSU65503 202SJul-18 11:05:57 Page2,€.ffcr ..,rch\Wightsoff\40SRedCliftCir(Glenwood).rup Calc=MJ8 FrontDoorfaces:NW f wrightsorr H?,r:"t:XS'"o Monarch HVAC Job: 408 Red Cliff Cir Date: 512'1125By: Toby Monger lnformationP For: Notes: Keith Wittenburo. Modfin Desion Build 233 Elk Valley L"ri, New Casilel CO 81647 Phone: 970-948-31 01 Email : shaggs09@yahoo.com Des Weather: Winter Design Conditions Outside db -2 "F lnside db 70 "F Design TD 72 "F VentilationMethod ASHRAE62"2-2019 Heating Summary Structure 43891 Btuh Ducts (R-8.0) 0 Btuh Central vent (t so cfm) 8194 Btuh Outside airHumidification 0 BtuhPioino 0 Btuh Equip."ment load 52085 Btuh lnfiltration Method SimPlified Construction quality AverageFireplaces 1 (Averag-e) Aea (ft') Volume (ff) Air changes/hour Equiv. AVF (cfm) Heating Gooling2320 2320 12 16 Heating Equipment Summary Summer Design Gonditions Garfield Co Rgnl, CO, US Outside db lnside db Desiqn TD Daily"range Relative humiditv Moisture differerice Air flow factor Static pressure Load sensible heat ratio 87 "F75 "F12'F H 5O o/o -35 gr/lb 19897 Btuh0 Btuh 1366 Btuh 0 Btuh n 0.92 19562 Btuh Sensible Cooling Equipment Load Sizing Structure Ducts (R-8.0) Centralvent (130 cfm) Outside air Blower Use manufacturer's data Rate/swins multiolier Equipmenl sensible load Latent Cooling Equipment Load Sizing Structure Ducts Centralvent (130 cfm) Outside air Equipment latent load Equipment Total Load (Sen+Lat) 19562 Btuh Req. total capacity at 0.70 SHR 2.3 ton Gooling Equipment Summary Make AmanaTrade AMANACond AXVOSA3610ACoil CAPEA3626C3A+ACVC960804CNB AHRI ref 215490105Efficiency 9.8 EER2, 16 SEER2 Sensible coolino 23100 Btuh Latent cooling " 9900 Btuh Total coolino 33000 Btuh Actual air fldw 1'l 00 cfm 77 Btuh0 Btuh -2451 Btuh 0 Btuh Make Trade Model AHR|ref Amana AMANA ACVC960804CN 7368878 8'l Btuh Btuh OF cfm cfm/Btuh in H2O 30212 0.36 181 302 0. 96.1 AFUEEfficiency Heating input Heating output Temoerature rise Actubl air flow Air flow factor Static pressure Space thermostat 80000 77000 80 1 100 0.025 0.80 0.055 0.80 1.00 cfm/Btuh in H2O Boldlitalic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed * y:*:r-gFI=--.1I"Righrsuite@ U niversal 2025 25.0.O2 RSU65503 2025-Jul-18 1 1:05:57 Page 1*&.,.rch\Wrightsoft\408 Red Cliff Cir (Glenwood).rup Calc = MJB Front Door faes: NW