Loading...
HomeMy WebLinkAboutREVISED Engineer's OWTS Design PlanINFILTRATOR SYSTEMS INC. QUICK4 CHAMBER SAME END SERIAL DISTRIBUTION TRENCH DETAIL (PLAN VIE1N) NOT TO SCALE SLOPE r� 4 STANDARD CHAMBER �- MULTIPORT END CAP INFILTRATOR SYSTEMS, INC. 6 BUISNESS PARK ROAD INFILTRATOR SYSTEMS INC. P.O. BOX 768 QUICK4 CHAMBERS OLD SAYBROOK, CT 06475 SAME END SERIAL PLEASE NOTE ALL INFILTRATOR CHAMBERS MAYBE BE USED IN THIS MANNER PH. (800) 2214436 FX. (860) 577-7001 DISTRIBUTION WWW.INFILTRATORSYSTEMS.COM TRENCH DETAIL Scale NOT TO SCALE Checked BCP Date 03/31/2006 Q4 SAME END Drawn By: KJB Sheet 1 Of 1 INFILTRATOR SYSTEMS INC. QUICK4 CHAMBER SLOPED SERIAL DISTRIBUTION DETAIL CROSS SECTION NOT TO SCALE DIFFERENT ELEVATION OVERFLOW ESTABLISH VEGETATIVE COVER 12" MIN., H-10 LOAD AREAS 6" MIN., NON -TRAFFIC AREAS 36" TY P. rr_rlt wvr- 47r PLEASE NOTE: ALL INFILTRATOR CHAMBERS MAY BE USED IN THIS APPLICATION INFILTRATOR SYSTEMS, INC. 6 BUISNESS PARK ROAD INFILTRATOR SYSTEMS INC. P.O. BOX 768 OLD SAYBROOK, CT 06475 QUICK4 CHAMBER PH. (800) 221-4436 SLOPED SERIAL DIST. FX. (860) 577-7001 DETAIL CROSS SECTION W WW.INF ILTRATORSYSTEW.COM Scale NOT TO SCALE Checked BCP Date 03/31/2006 Q4 SERIAL X Drawn By: KJB Sheet 1 Of 1 INFILTRATOR SYSTEMS INC. QUICK4 STANDARD CHAMBER QUICK4 STANDARD MULTIPORT END CAP 801 O-Z INFILTRATOR SYSTEMS, INC. 6 BUISNESS PARK ROAD P.O. BOX 768 INFILTRATOR SYSTEMS INC. OLD SAYBROOK, CT 06475 QUICK4 STANDARD PH. (800) 221-4436 CHAMBER DETAIL FX. (860) 577-7001 W W W.IN FILTRATORSYSTEMS.COM Scale NOT TO SCALE Checked BCP Date 03/30/2006 Q4 STDTECH Drawn By: KJB Sheet 1 Of 1 QUICK4 CHAMBER INSPECTION PORT TYPICAL INSTALLATION DETAIL (Not to Scale) Option A: CHAMBER RISER TO GRADE TTACH CAP OR THREADED CLEANOUTASSEMBLY .:• I • � �� �• ` ° Tr +� •. ;• ..,, �,, 1, Z'• ��; . a'��: QUICK4 STANDARs. "�Lt:, x _e •:� �' '/•' :. 'PVC F1PECUT TOFIT USE HOLE SAW �' REST 4' PVC PIPE ON TOP OF '..; INSPECTION PORT SEAT. TO CUT OUT ;. PRE -MARKED CIRCLE ;� SECURE IN PLACE WITH A DRYWALL SCREW Option B: INSTALLATION WITH VALVE BOX SMALL VALVE COVER BOX OR IRRIGATION VALVE BOX AT GRADE .� : h;`• t .+'; : `• ` _'= t' TTACH CAP OR THREADED y"+. •' ,� , _ ,,,• .• ./; CLEANOUT ASSEMBLY COMPACT SOIL BASE ' ' �• TO SUPPORT BOX F��»`•i:� ._:;•� f;• '�YI `, t t t:`i�,•x»'i�' y• 4'PVC PIPE CUT TO FIT USE HOLE SAW REST 4' PVC PIPE ON TOP OF TO CUT CUT ;. .iy� INSPECTION PORT SEAT. PRE -MARKED CIRCLE SECURE IN PLACE WITTY A DRYWALL SCREW INFILTRATOR SYSTEMS, INC. 6 BUISNESS PARK ROAD P.O. BOX 768 INFILTRATOR SYSTEMS INC. OLD SAYBROOK, CT 06475 QUICK4 STANDARD PH. (800) 221-4436 FX. (860) 577-7001 INSPECTION PORT DETAIL W W W.IN FILTRATORSYSTE W.COM Scale NOT TO SCALE Checked BCP Date 05/ 19/2006 ACAD No.asm INSPEcnoNPORT Drawn By: KJB Sheet 1 Of 1 ' - / ',/ / ♦/ f - _ ' 0 e / �40 e if � \ / / / / / \ \ /„- ♦ 4e Conc. u ,K.. Profile Holes (2) INFILTRATOR SYSTEMS, INC: PLACEMENT OF FILL MATERIAL WITHIN ZONE OF DISPOSAL UND FOR PROPER DRAINAGE 3'-4' max 8' CONFINING LAYER NOT APPLICABLE TYPICAL TRENCH DETAIL SHEET NOTES: 1) REFER TO MANUFACTURER FOR ADDITIONAL INSTALLATION REQUIREMENTS @ WWW.INFILTRAI<TOR.COM FOR QUICK 4 SERIES PRODUCTS. 2) REFER TO VALLEY PRECAST FOR ADDITIONAL TANK, PUMPING AND CONTROL SYSTEM REQUIREMENTS @ WWW.N'ALLEYPRECAST.COI OR (719) 395-6764. 3) ALL SEPTIC ELECTRICAL TO BE BY VALLEY PRECAST OR OWNER'S MASTER ELECTRICIAN EXPERIENCED IN SEPTIC PUMPING SYSTEMS AND NEC REGULATIONS. Q4 Infiltrators f , - u ns"of 2 2ve e�e/ .-1 00 e J* 1 44 tott" I t , ,-'' , / ,- 10 - J1?7 V) oc', 01 e e t + f o % 40 , 4 / '01 j ,, 1 r -, / Its AV 00, e , ,• / 40, ' `A i eef A ee AV Air ,'' i" ; ' � TOP WALL 8878 R3 I box I epee I - � 4?0 `X Cd FT p ,,-.0 - 00 // e j (D ; F ,a z , Clean 4 6 \ a. AIA4�. + < , ; it 11 , \ Out I y A o ♦' 20 + i 0 AMP f f �' o / ` V F� = METER LOAD o- o \ ` Q SST/ CENTER-W ,-/ cc o00c� \ \ /,, R�� " rG ,/ �� l r ii OQ t \ Fri �* DISCONNECT -' � / \ - Ile , • f , .0, \ ,- + + ____,/ If �, 1 PURE ORE ---'' + '`-, 1/' ►DATER ERVIC�' ,- 44* Je \ / r. + � ,� /' NV 2) 2" SCH.80 �-«.'• - t j \ / G E LEC. , _`� 'ell / I / + , It 58'@ 2mn. ,' / / e #e04.0 100 ALLON� i N - /' ``\ r #1e lop OPANE r O� � ,' \„ �, y,/ � ; - TANK , r'- ,e e e 100e ee .0 Sch 40 inspect -- ,- .� ram. ., -► `, ,- ,/ ,-- / �- , 41 POWER POLE _/ ,r.1 00 New 1 50.06*qallon ,. -� 1 r / r ' /10 precast'concrete , r septic tank with bio filter ew"�* o Zo» 40'PTIC PL tvemm C2s 4 LEX i A% L.f "' nvg &[Q�T 10 0 � VG70XIA17 Pr PEP) BROCK CIVIL, LLC Professional Services P.O. BOX 23 Eagle, CO 81631 Cell 970-471-2121 JULY 151 2025 7W Christian Ranch. LLC. 3412 CR 151, Garfield County, CO PN: 186328100118 DESIGN CALCULATIONS FOR DOMESTIC LOADS Garfield County On -Site Wastewater Treatment System Regulations adopted March 6, 2023 ("Regulations"). Colo. Dept. of Public Health and Environment Regulation #43 5 CCR 1002-43. DESIGN FLOWS Number of bedrooms = 3 Number of persons per bedroom = 2 (design flow) Single Family Residential Design Flows = 75 gallons/day/person Q design = 3 bdrms x 2 persons/bdrm x 75 gallons/person/day = 450 gpd PER 43.6 TABLE 6-1, USE 450 GPD SOILS PROFILE (Visual and tactile investigation): Soil Type 2 ( See USDA)_ From profile hole 1 - sample at 4 ft. Ribbon 17 mm Profile Holes (2) Textural Classification 0.0 to 1.0 ft Topsoil with heavy organics 1.0 to 8.0 ft Silty loam and sand, single grain structureless, granular (USDA) No groundwater. No wetting of soils or mottling in profile holes PERCOLATION TESTS: (June 8th, 2025) Visual and tactile evaluation of the treatment soil indicates silty loam, sandy with a percolation rate of 15 Minutes/Inch, with no limiting layer. INFILTRATOR CHAMBER SYSTEM IN SERIAL TRENCH DISTRIBUTION Given this information, the residence would be best served by a chamber system in serial trench distribution. Treatment Level 2 Effluent: Per Tables 6-2: 10-1. Surface of Soil Treatment Area (STA) shall be based on LTAR and not the percolation rate. Soil Treatment Area = Design Flow (gals/day)/LTAR gal/day/SF. • Long Term Acceptance Rate is estimated to be 0.6 Gal/day • Reductions: (per 43.10.D. Tables 10-2 & 10-3) Trench serial chambers: 0.7 • Design Flow = 450 GPD I (0.6 Gal/day/SF) X 0.7 = 525 GPD • Using standard Quick 4 Infiltrators: 525 GPD / 12 SF per infiltrator = 44 infiltrators • Trenches shall be (2) runs of (22) infiltrators; Total (44) • Valley Precast 1,500 gallon tank • Chamber Product to be Infiltrator Systems, Inc. "Quick 4" Low Profile Chambers. SEPTIC TANK: Per table 9-1, for a maximum 3 bedroom residential structure, Minimum Tank Capacity is 1500 gallons in the first 2 chambers. Proposed Valley Precast Tank 1500 gal 2 compartment: Inlet side 1002 gallons and Outlet 507 gallons. Water tightness per Section 9, ASTM C 1227-12. INSTALLATION Install all components to the required setbacks required by regulations. No over excavation allowed for septic tank or trenches. DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 62.33 ft' • f c 0 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with we+or table less than 2' below grade • Meets C1644- 06 for resilient cor • Inlet and Outlet identified above • Delivered complete with internal • PVC or concrete risers available • Secondary safety screen availabl( PVC riser • Option of pump or siphon install ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0' - 0" 3' - on 1'-off 3'-0" 2'-0" 4'-o" 3' - 0" 4' - on DRY 4' - on CHAMBER TRENCH CONSTRUCTION: Dig trench to geotechnical average depth to top of silty, sand loam (max 4 ft); Engineer to inspect. Install chambers level in 2 run of 22 N ty Y g p () (� chambers. Backfill the chambers and all voids to top of chambers. Import may be re .luired for proper backfill. U(� W TOP SOIL CONSTRUCTION: Back fill over chambers with 12 inches of high organic o 't -� 0 op 0 � U soil and reseed to native vegetation. Do not compact top soil. Mound topsoil for pc sitive runoff, 1 ft.-18 inches. SEPTIC TANK & PIPE CONSTRUCTION. Install septic tank level with 5 sarLd gravel U bedding. Install the delivery pipe from the residence to the septic tank minimum 20i ') slope, > X Schedule 40 PVC (preferred) (ASTM D 2665). Septic tank to have risers brought tc final grade 0 0 0 U el U and shall have a secure locking mechanism. Glued fittings for both pipe types due t �� tree roots. [n I Q J ff NOTES: 0 (� 1. The building sewer line from the house to the septic tank shall have a slope of /4 inch per �./ O o U foot 2 /o . Bends in the builds sewer shall be limited to 45 degrees. U 2. Use topsoil for vegetative cover. n C p Q 3. Assemble and install the Infiltrator Chambers in the trenches according e to the W W manufacturer's recommendations. ry Li> 4. Vehicle traffic, animal concentrated loads and irrigation over the system is prohibited. [n _j Fencing advised. �- 5. The Septic System Installation shall be inspected by the Design Engineer prio r to backfill. LL Installer to call 970-945-6614 ext. 8150. Q 0 6. All installations shall meet the rules and regulations of the Garfield County Environmental W Health Department. 7. Electrical requirements of alarm to be detennined by Electrical Contractor pri, "►r to construction. 8. The Bio effluent screen shall be installed in the outlet tee of the second chamber with both tees visible from the access portals. Screen shall be maintained annually or a: needed. 9. Pump septic tank every 2-3 years minimum to prevent deterioration of concre•:I.,. 10. Installer must be a qualified installer. 11. This system replaces ISDS # 1728; Frontier log home. MINIMUM DIMENSIONS TO FACILITIES -�, C ACTUAL REQ D) SEPTIC TANK TO BUILDING 13 FT (5 FT) y. SEPTIC TANK TO WATER LINE 160 FT (10 FT) *4 SEPTIC TANK TO TRENCH 40 FT (10 FT) SEPTIC TANK TO SPRING/WELL NA (50 FT)_ AV ram} ABSORPTION TRENCH TO SPRING/WELL NA (100 FT) ABSORPTION TRENCH TO BUILDING ro Q FT (20 FT) ABSORPTION TRENCH TO WATERLINE Q 'FT (25 FT) ABSORPTION TRENCH TO IRRIGATION NA FT (50 FT) ABSORPTION TRENCH TO PROPERTY LINE 90 FT + (10 FT) BUILDING SEWER TO WATER LINE 440 FT (10 FT) See 43.7, Table 7-1 for further information and requirements if changes are m� Ae to assure proper clearances. lt,s 11415 5Y5TEM RkIPLAoc.17000,8 I r SANDY LOAM 60% SAND 30% SILT 10% CLAY 132" 44 ` 4 2011 Clear Access , CL V. TANK ID 4. 4 , j 1� •4 129" Top View Section View Digging Specs Invert Dimensions Net Capacity Net Weight 13' Long x 8' Wide 56" below inlet Inlet Outlet Length Width Height Inlet Side Outlet Total Lid Tank Total 56" 53" 132" 68" 68" 1002 gal 507 gal 1509 gal 3600 Ibs 11180 Ibs 14780 Ibs 88T` 11+/. (USGS) U J 0 Ln U 00 Z U 0 Q z ry z 0 D 0 00 � N U Z z cno � Q D o oo � 0 UW W cn L Z N < n SHEET SS1