HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PER MIT
BLRE-0 6-25-9301
FEDERICO & GRACIELA PENA
New Single-family dwelling w/ attached garage
12 Weeping Willow Lane, Carbondale
Roaring Fork Preserve, Lot B - 239336319008
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.N.C.)
AND 2O1B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACH ED "GARFI ELD COU NTY BUILDI NG REOU I REM ENTS". NUM BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) ALL EXTERIOR LIGHTING TO BE DOWNCASTAND SHIELDED.
S) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLYWITH WILDFIRE
MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE
FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY
COM MUN ITY DEVELOPM ENT WEBSITE FOR ADDITIONAL I NFORMATION.
6t OPEN HOLE SOILS REPORT lS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE
BUILDING INSPECTOR. 3,000 PSF soil bearing. pRovrDE coMpACTroN REpoRT /FSTRUCTURAL FILL.
7) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUILDING INSPECTOR AT
TIME OF FRAME INSPECTION.
B) ALL HtcH STRENGTH BOLTTNG AND FrELD WELDTNG REOUTRES SPECIAL INSPECTOR.
PROVIDE APPROVAL REPORT AT FRAMING INSPECTION.
s) BUILDINGS lN ROARING FORK PRESERVE REOUIRE A FIRE-SUPPRESSION SYSTEM. FIRE
SPRINKLER PERMITS, PLAN REVIEWS, ROUGH-IN, FIRE SPRINKLER FINAL INSPECTIONS
THROUGH CARBONDALE & RURAL FIRE PROTECTION DISTRICT. UULY2l,2O25UPDATE:
GENERAL CONTRACTOR CONFIRMS FTRE INTEGRITY SERV'CES WILL SUBMIT TO FIRE D'STRICT FOR PERMIT
PRIOR TO INSTALLING THE SPRTNKLER SYSTEM).
10) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO BUILDING lNSPEcrloN & CERTIFICATE oF
OCCUPANCY PROVIDE FINAL APPROVAUSIGN.OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
1 1 ) BLOWER DOOR TEST tS REOU|RED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
12) PRESCR|pTtVE PATH USTNG 2018 rECC TABLE R402.1.2 rS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME DESIGN. SEE ALSO SHEET AO.O3 AND WRIGHTSOFT MANUAL J REPORT ATTACHED FOR
REFERENCE. ALL NEW HOMES TO HAVE WHOLE.HOUSE MECHANICAL VENTILATION SYSTEM
INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET.
\
$
"\It
s\
$'
s