January 2,2025
Ram Development
Attn: Bobby Almazan
P.O. Box 1387
Carbondale, Colorado 81 623
bobbv@ranrdev.builcl
Project No.24-7-675
Subject: Observation of Pit Excavations, Ptoposed Residence, l2 Weeping Willow Lane,
Lot 8, Roaring Fork Preserve, East of Carbondale, Garfield County, Colorado
Gentlemen:
As requested, a representative of Kumar & Associates, Inc. observed the excavation of 3 pits at
the subject site on December 4,2024 to evaluate the soils exposed for foundation support, The
findings of our observations and recommendations for the foundation design are presented in
this report. The observation was periormed in accordance with our agreement for professional
services with Ram Development dated November 25,2024.
The development area is relatively flat, open irrigated field with a slight slope down to the west-
northwest. Vegetation consists of field grass in the proposed development area.
At the time of our visit to the site, three pits were excavated about 3% to 6 feet below the
adjacent ground surface. The soils exposed in the pits consisted ofabout I foot oforganic
topsoif and I to 1/' feet of sandy silty clay overlying relatively dense, slightly silty sandy gravel
with cobbles down to the maximum depth explored of 6 feet. The results of a gradation analysis
performed on a sample of the sandy gravel soils (minus 6-inch fraction) obtained from the site
are presented on Figure 3. No free water was encountered in the pit excavations and the soils
were slightly moist. Our experience in this area is that groundwater can rise to within 4 feet of
the ground surface.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the expected construction, we recommend spread footings
placed on the dense gravel soil designed for an allowable soil bearing pressure of 3,000 psf for
support of the proposed residence. Footings should be a minimum width of l6 I loI
continuous walls and 2 feet for columns. Loose and disturbed soils and existing topsoil and clay
encountered at the foundation bearing level within the excavation should be removed and the
footing bearing level extended down to the undisturbed natural gra vel soils. If needed, structural
fill placed below footings should consist of
rffipactedtoatr
the on-site granular soils or a suitable soll
east 98% of the maximum standard Proctor density
at a moisture content near optimum. Exterior footings should be provided with adequate cover
above their bearing elevations for frost protection. Placement of footings at least 36 inches
Ram Development
January 2,2025
Page 2
below the exterior grade is typically used in this area. Continuous foundation walls should be
reinforced top and bottom to span local anomalies such as by assuming an unsupported length
of at least l0 feet. Foundation walls acting as retaining structures should be designed to resist a
lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for the on-site
gravel soil as backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil and any disturbed soils from previous
excavation on the site, are suitable to support lightly loaded slab-on-grade construction. To
reduce the effects of some differential movement, floor slabs should be separated from all
bearing walls and columns with expansion joints which allow unrestrained vertical movement.
Floor slab controljoints should be used to reduce damage due to shrinkage cracking. The
requirements for joint spacing and slab reinforcement should be established by the designer
based on experience and the intended slab use. A minimum 4 inch layer of free-draining gravel
should be placed beneath basement level slabs to facilitate drainage. This material should
consist of minus 2-tnch aggregate with less than 50%o passing the No. 4 sieve and less than2o/o
passing the No. 200 sieve.
Atj!th@supportoffloorslabsshouldbe-9ompactedto3tleast.95%oofmaximum
stai?Iffil-Proctor density at a moisture content near optimum. Required fill can consist of the
on-site gravel soils devoid of vegetation, topsoil and oversized rock or an imported gravel soil,
such as t/+-inch road base.
Underdrain System: Although free water was not encountered during our exploration, it has
been our experience in the area that local perched groundwater can develop during times of
heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched
condition. A previous pit dug on this site in 2000 showed groundwater at 4 feet deep. We
recommend below-grade construction, such as retaining walls or deep crawlspace areas, be
protected from wetting and hydrostatic pressure buildup by an underdrain system. Slab at grade
construction and shallow crawlspaces should not require a perimeter drain.
If installed, the drains should consist of drainpipe placed in the bottom of the wall backfill
surrounded above the invert level with free-draining granular material. The drain should be
placed at each level of excavation and at least I foot below lowest adjacent finish grade and
sloped at a minimum 1%o to a suitable gravity outlet or sump and pump. Free-draining granular
material used in the underdrain system should contain less than 2Yo passing the No. 200 sieve,
less than 50% passing the No. 4 sieve and have a maximum stze of 2 inches. The drain gravel
backfill should be at least 1% feet deep. Due to the relatively flat temain, if installed, the
perimeter drain system will need to be pumped to a ground surface outlet.
Surface Drainage: The following drainage precautions should be observed during construction
and maintained at all times after the residence has been completed:
Kumar & Associates, lnc. @ Project No. 24-7-675
Ram Devsiopm*nt
Janua:'y 2,2{}25
Fage 3
1)lnundatic* of tha: fbundati*n exoavatielr'ls and underslab areas should be avoirled
during eoi:structi*n.
Exterior haekfill sh*uld be adjusted to trear *ptin:r.im moisture and ccn:pacted tir
at least 957i' *f the maximsm s*indarei Pr*ctor d*nsity in paveinent and slab areas
and tc at least 909/<r of the ntaximum stanelard Froct*r dearsity in landseape areas.
Free-draining wall hackfill should b* eapped with ab*ut 2 fect of the on*site, tiner
graded soils t* reduce s*rface water infiltrati**"
Th* ground surf"a*e s*n"*unding the exteri*r *f the building shauld b* sloped to
elrain away fi"arn the f**ndation in altr rlirecti*trs" We r*e*fixitsnd a miniffium
strop* of $ inches i* th* {irst } * lbet in unpav*d areas and a minimum slope of
3 inehes in th* first l* feet in pavem*nt anc{ walkway er"eas.
Itoaf"downspcuts and clrains should diseh*rg* lr'eil beycnd the iimits of all
backfill"
4j
The re*a:nmq:ndati*:rs subr*itted in this l*its:r are bas*d *l: sur o?rservation of th* soils exposed
within th* ;:it exeav*tion$ et thc site" Variations it: tl:c] s*bsrrrihee eon*liti*ns b*lcw the
sxeavatian eclul{i in*rease the risk s}f f$undaticil tnovcret*nt. We shqruld be advised *f any
variations ene*unterecl in th* sxcava?i*rl e*nditi*ns for p*ssibl* *h*a:ges to reeomrnendatia:rs
ecxg*.;nsd in this letter. Our s*rviess d* not include dstennining tho presenec, prevention or
passibility of rnrild or other bioltlgiea} eontami*ants {I\4OEC} d*ve}*:ping in tla* future. If the
elient is ccfl*eril*d ai:*ut M{}BC. then a professianal in this sp**iai Seld *f Braetiee should be
cansulted.
If you have any qu*stions *r ir*ed firther assistane*. please eall aur otfice^
Sineerely,
Wummr & {qxn**E:*t*s
2)
3)
Daniel E. Hardi*,
Rev. by: SLP
DflF{lkae
attaehme:?ts Figure I *-Loeati+n of Hxpl*ratory Fits
F'ig*re 2 - Logs cf Expl*rai*ry Fits
Figure 3 -- Gr:adaiian'tr'*st Results
F,.vm p,t &" fa*t;i*ti&l*r;, 4**, e Fruja:9 ffier.24"?"S?S
150 0
APPROXIMATE SCALE-FEET
0
24-7 -675 Kumar & Associates LOCATION OF EXPLORATORY PITS Fig. 1
tl
-\-
A
PIT 1 PIT 2 PtT 3/SEPT|C PROFTLE PrT
0 0
Ft!t!tL
IIF
TL
trJo
q I ++=os- -200=5 5
Ftrl
Lrl
LL
I-F
o_
Lrlo
10 10
LEGEND
TOPSOIL. ORGANIC SANDY CLAY WITH ROOTS, SOFT, MOIST, DARK BROWN
CLAY (cL); SILTY, SANDY, MEDIUM STIFF To STIFF, MolST, DARK BRoWN
GRAVEL (GM_CP); AND COBBLES, SANDY, MEDIUM DENSE TO DENSE, MOIST, BROWN
Ir
DISTURBED BULK SAMPLE
NOTES
1. THE EXPLORATORY PITS WERE EXCAVATED WITH A BACKHOE ON DECEMBER 4, 2024
2. THE LOCATIONS OF THE EXPLORATORY PITS WERE MEASURED APPROXIMATELY BY PACING FROM
FEATURES SHOWN ON THE SITE PLAN PROVIDED.
3, THE ELEVATIONS OF THE EXPLORATORY PITS WERE NOT MEASURED AND THE LOGS OF THE
EXPLORATORY PITS ARE PLOTTED TO DEPTH
4. THE EXPLORATORY PIT LOCATIONS SHOULD BE CONSIDERED ACCURATE ONLY TO THE DEGREE
IMPLIED BY THE METHOD USED.
5. THE LINES BETWEEN MATERIALS SHOWN ON THE EXPLORATORY PIT LOGS REPRESENT THE
APPROXIMATE BOUNDARIES BETWEEN MATERIAL TYPES AND THE TRANSITIONS MAY BE GRADUAL.
6. GROUNDWATER WAS NOT ENCOUNTERED IN THE PITS AT THE TIME OF EXCAVATION. PITS WERE
BACKFITTED SUBSEQUENT TO SAMPLING.
7. LABORATORY TEST RESULTS:
+4 = PERCENTAGE RETAINED ON NO. 4 SIEVE (nSfV O +ZZ);
-2oo= PERCENTAGE PASSING No. 200 SIEVE (ASTM D 1 1 40).
--}-
24-7 -675 Kumar & Associates LOGS OF TXPLORATORY PITS Fi1. 2
.};
HYDROMETER ANALYSIS
U.S. STANDARD SERIES CLEARTIME READINGS
1.9tr.l!L.M!tl
24 HRS 7 HRS
,l
too
90
ao
70
60
50
10
50
20
to
o
10
20
30
40
50
6o
70
ao
90
r00
z
I
i
lr
1 .14
o
.oor
I llrl ......]r.. r ,r t r.oo9 .ot 9 .o37 .075
: .l
150
DIAMETER OF
-125
PARTICLES INM ERS
CLAY TO SILT COBBLES
GRAVEL 6A % SAND
LIQUID LIMIT
SAMPLE OF: Sondy Groval with Cobbles
29%SILT AND CLAY 3%
PLASTICITY INDEX
FROM:Piil@3'-3.5
Thsso tsst resulls opply only to tho
sompl€s which w€r6 l€sl€d. Tho
lostlhg reporl sholl nol be r€produced,
exc€pl in full, wilhoul the wriltsn
opprovol ol Kumor & Associolos, lnc.
Slev€ onolysls lesllng ls performed ln
occordonce with ASTM 06913, ASTM 07928,
ASTM Cl36 qnd/or ASTM Dl'140.
GRAVELSAND
FI NE MEDIUM COARSE FINE COARSE
24-7 -675 Kumar & Associates GRADATION TEST RTSULTS Fis.3