STATE OF COLORADO
Cover Sheet for Building Specifications, Third Party
Reviews, and QA Manuals
Name of Manufactu ,".r. Clayton Homes Albuquerque Ptant l.D" Number: 174
Manufacturer Address:2700 Karsten CT. SE. Albuquerque NM 87102
Manufacturer Contact Name and Contact Number:Richard Martinez, Service: Mike Sena (505) 242-5580
Manufacturer Contact Ennail address:Richard.Martinez@ClaytonHomes.com, Service: Mike.Sena@ClaytonHomes.com
Third Party lnspection Agency (if not CDOFI). NTA
Third Party Plan Review Agency (if applicable):NTA
Third Party Plan Review Approval Narne/Number (if applicable):NTA
Factory Type: Vft FBNR Tiny Homes HUD Homes
Document Type: fZ New elan Revision Renewal
CUSTOM 2776 CONRADModel Name/No.:'
.$)
MANUFACTURER CERTIFIES that onty approved equipment and materiats witt be used and the instattationsl i
shatt be made in accordance with approved ptans and appticable codes and provisions of the Colorado\
Division of Housing. Manufacturer agrees to in-ptant inspection of units manufactured under the above
ptan approvat. Apptication shatt be made for and insignia affixed to each factory built unit that is subject S\
to Colorado statutes and which is manufactured or is to be sotd, offered for sate, or occupied in the state. \ )
of Colorado.
Sq
5q
Footage Pin;shs4; 2052
Footage Unfinished:
CDOI-I Approval Stamp
Expiration Date CDOH Plan Approval Number
DIV. OF HOUSING, 1313 SHERMAN STREET, RM 320, DENVER, CO, BO2O3
Contact Information: FB/FBNR Factory manufactured.plans@state.co.us or Tiny Homes dola tinyhomes@state.co.us
N
\$
reet COLORADO
Department of Local Affairs
Division of Housing JULY 2023
Model Number . CUSTOM 2V76 CONRAD
R.esidential (lRC) & Tiny Honne Plan Subrnission Checklist
A futt plan set submission to the Colorado Division of Housing includes the following:
(Electroni c PIan Submi ssi ons Only)
Covernor Jared 5. Potis I Rick M. 6arcia, Executive Drrector I Atison George, Divjsion Director
j313 Sherman St., Room 320, Denver, C0 80203 P 303.864.7810 F 103.864.7857 TDD/TTY 303.864.7758 www.dota.colorado.gov
5t r e ngtheni ng Co lo rado Communi ti e s
Submitted Document Type
/a Ptan Review Payment through Satesforce
an Set Pa
Architectural Pian Set
a lnitiated and signed copy of the Ptan Submission Checktist confirming appticabte
documents have been inctuded in the ptan package.
IA a lndex of submitted ptan package
o Can be a separate document or ctearly denoted on cover page
,/
Site location where structure is to be instatled, and Loca[ Authority Havingo
Jurisdiction, or designate the structure as lot modet with design [oads that are specific
for the area the home can be instatted, and a minimum setback distance noted for
fire separation requirements. lf site location is known, a site ptan, set back distances
to tot [ines or other structures, and [oca[ AHJ Witdfire Mitigation area requirements
(if any) are required to determine fire separation requirements for structure. lf
structure is to be set in a location where there is no [oca[ authority having jurisdiction
or tot modet, at a minimum, the design [oads must compty with 8 CCR 1302-14, Rute
2.2.1.
a Code Anatysis
o Design Codes
o Wind, and Snow Loads (must meet [oca[ AHJ and CDOH minimums)
o Seismic and Wind Exposure category
o Type of Fire suppression system if appticabte (factory instatled or on site). lf tocation is known, clearty denote on code analysis if the jurisdiction
require a fire suppression system. lf one is required and any of the
instatlation is to be in-plant, then it must compty with Colorado Division
of Fire Safety & Controt Rutes (8 CCR 1507"11) & a CORI shatt
acc the units the
a List of items to be compteted on site
o OC Form inctuded that compties with 8 CCR 1302-14, Rules 1 .19, 4.17.1.1, and
C. R. s. 24-32-331 1 (1 )(a.71
o Architecturat ptans with appticable detaits
o Ftoor Plan for Each Level
o Room Use Specification
o Window and Door Schedutes
o Etevations
o Section Drawings (Futl. and at Stairs)
I
-TQUAI HOUSING
O'PORIUNITY
regli,f##"o""lo*o"JULY 2023
Governor Jared S. Fotis I Rick M. Garcia, Executive Director I Atison George, Division Director
i313 Sherrnan St., Roonr 320, Denver, CO 80203 P 303.864.7810 F 303.864.7857 TDD/TTY 3A3.864.7758 www.dota.colorado.gov
S t re ngthen i ng Co lo rado iommuni ti e s
Fire Rated Assembly Details (lf appticabte)
o Assembties not exempt in section R302 to be fire rated or other sections in the
code, need to have detaits showing comptiance with section R302 of the IRC
for separation of dwetlings, fire separation distances, and/or ftoors. Must
compty with the testing standards of either ASTM E119 or UL263 or section
703.3 of the lBC.
o lf section 722 of the IBC has been opted for comptiance, the design must be
approved through a Colorado Registered Fire Protection engineer.
a
Structural Framing Plans
Componentso Floor Assembties
o Watt Assembties
o Roof Assembties
o Ceiling Assemblies
o Headers, Beams and Cotumns
o Proposed Foundation
o Braced Watl line detaits, and tie down equipment with locations that are not
specificatty addressed in approved instaltation manual.
o Construction components exceeding section R301 of the lRC, sha[[ have ptans
stamped by a Cotorado Registered Design Professional.
MEP Plan Sheets
IA Mechanical System Ptans
o Exhaust Locations
o Whole home ventilation systems
a
a Electricat System Ptans
o Fixtures, load catculations, panet/circuit schedute with breaker and wire
sizing, symbots etc
a Ptumbing System Plans
o Service water piping with piping location, insutation and size
o Fixture types and locations
o lsometric for DWV, indicate pipe sizes
a Gas System Ptanso Gas lsometric with distances and BTU ratings of apptiances it serves
o Piping material and sizes, service pressure ratings
Spec Set, Pockoge
,t/a Spec Cover Sheet
a Copy of the "OC" lnspection tetter denoting the "OC" inspection items tisted on the
submitted ptans. lnformation from the site address on the first page to the "factory
authorized representative" portion to the date must be fitted in by the factory, except
for the CDOH P/A NO DOH
o Engineered/Certified Component Detaits
o Engineered and stamped truss detaits by a State of Colorado professional
designed per TPI 1 - ?014 per IRC 2018. lnctude correct [oading and wind speed
& exposure, etc.
o Tiny Home chassis must be engineer approved or certified by NHTSA
a Energy Comptiance
II
EOUAL f,OUStNG
OPPORIUNITY
reet COLORADO
Department of Local Affairs
Division of Housing JULY 2023
The Colorado Division of Housing plan review does not begin until the entire plan submission is
received.
Appticant must sign betow acknowtedging submittal checktist has been read and atl appticabte
documents have been submitted for review and any changes to ptans require plans to be resubmitted
for review, and approved by DOH before construction. Att DOH ptans are subject to fietd inspection.
Additionat information not inctuded in this general tist may be requested by DOH ptan reviewers to
complete review.
Richa rd L. Marti nez iil[?'y'L1ffi1?',Tl!1i3 !'}|T'"*5-15-25
Date:
For additionat plan review requirements, questions, or concerns, please reach out to our staff at:
FB/FBNR
manufactured. plans@state. co. us
Tiny Homes
dota tinvhomes@state.co. us
Governor Jared S. Polis I Rick M. 6arcia, Execuiive Director | .Atison George, Division Djrector
1313 Sherman Sr., Room 320, Denver, C0 80203 P 303.864.7810 F 303.864.7857 TDD/TTY 303.864.7758 www.dola.colorado.gov
St re ngthe n i ng Co Io rado Communi ti e s
a
o REScheck (signed). Use appropriate version 20'15 (or 7012,2009 based on tocal adoption). Use the Colorado city where the buitding witt be installed (lf site
location is not a selection on REScheck, tist exact [ocation on
Construction Site information box)
lf a REScheck is omitted and the prescriptive method is opted for use, ptease clearty
denote on ptans a tabte showing the information depicted in the IECC, Section R103.2
and appl icabte information per 8 CCR 1302-14, Rute 2.7
w
HVAC System Plans
o Load calcutations for equipment sizing (Manuat J)
o Equipment size listed and meets or exceeds load calcutation with deration
(Manuat S)
o Suppty and return air sizing and ptans (Manuat D)
o Site information must match information ded on the REScheck
a
II
IQUAI BOUSINo
OPPOtrTUNIIY
reel COLORADO
Department of Local Affairs
DMsion of Housing luLY 2023
r'OC" (On-site Construction) Form
Flease read below before signing form.
please See Attached Document at bottom of form for Specific plan and Manufacturer information.
To: The Local Authority Having Jurisdiction (LAHJ) or other DOH approved third party inspection
agency.
By signing this form, you confirm that you have received and reviewed this form, and acknowtedge that
the identified components below are required to comptete the construction of this modutar structure
onsite within your jurisdiction.
Buitding Officiat Responsibitity
please check the box tabeted "Accept" and initial to confirm that you wit[ take responsibility for
inspections of the "OC" lnspection ltems on behatf of the DOH. You also acknowtedge that it witt be
done to the DOH aPProved Ptans.
lf you would tike to defer inspection of the "OC" lnspection ltems back to the DOH, ptease check the
box labeted "Defer lnspection".
*AfiENTION*
,,On-site Construction" or "OC" means on-site construction or modification of the factory'buitt structure
that directty retates to the durabitity, quatity, and safety; that is compteted at the instaltation "site" as
defined by iection 24-32-3302(33), C.R.S.; using components not instatted at the manufacturer's
location; and to comptete the comptiance of that structure as reflected in the Division of Housing
approved plans. These items do not include the component(s) required for setting and securing the
structure for its instattation.
Fire Safety Officiat Responsibitity (i'f appticabte)
The DOH defers the requirement of any fire protection system for a[[ modular IBC (Section 901.2) and
IRC (Section R313) structures as foltows:
An automatic fire sprinkler system shatt be instatled in buitdings (lBC) OR one and two famity dwetlings
and townhouses (lRC) OR Tiny homes as required by the [oca[ jurisdiction where the structure or home
witt be set. Final tests required by this Section sha[[ be approved by a certified inspector. The inspector
must be either an emptoyee of the fire department having jurisdiction or another qualified individual
with prior approval of the Colorado Division of Fire Prevention & Controt.
Witd Fire mitigation requirements witt be deferred for (lBC) OR one and two famity dwetlings and
townhouses (lRC) OR Tiny homes as required by the local jurisdiction where the structure or home wilt
be set. Final inspections required by tocals shatl be approved by a certified inspector. The inspector
must be either an employee of the fire department having jurisdiction or another quatified individual
with prior approval of the Cotorado Division of Fire Prevention & Control.
Governor Jared S. Potis I Rick M. Garcia, Executive Director I Atison George, Divjsion Director
1313 Sherman St., Room 320, Denver, C0 80203 P 303.864,7810 F 303.864.7857 TDD/TTY 303.864.77-\B www.doia.colorado.gov
St re ngthening Co{o rado Communi ti e s
II
EOUAT HOUSING
O PPORlUNITY
reel COLORADO
Department of Local Affairs
DMsion of Housing luLY 2023
Please confirm if the LAHJ requires a fire protection system and/or witd fire mititgation for this modular
structure. lf so, ptease indicate if the inspection wi[[ be completed by a fire department (identify which
one) or whether it witt be compteted by the Cotorado Division of Fire Prevention & Controt.
Manufacturer Responsibitity
The registered manufacturer is responsible for manufacturing a structure that is compliant with our
Administrative Rules (CCR 1302-14). lf items in the factory have not been compteted, onty to be
completed in the fietd, you are sti[[ responsible for ensuring they have been completed for comptiance.
Ptease sign betow that you have received this letter and acknowtedge the items listed are to complete
comptiance of the structure, and items are to be inspected and passed for compliance in order to meet
Rute 1 .13.1 and section 24-32-3311(4), Colorado Revised Statutes (C.R.S.).
*ATTENT]ON*
A DOH issued insignia (silver for residential or blue for nonresidential or pink for tiny homes or black for
mutti-family) certifying its construction cannot be affixed to the structure untiI all "OC" items are
compteted on site and pass inspection. The same applies to modular structures manufactured by a
certified manufacturer.
Acknowledge Receipt and tJnderstanding
Norma[ permits and fees for these site work inspections are to be per the [oca[ jurisdiction.
State approved plans for Factory-Built Construction may be obtained from the Builder/Manufacturer
A copy of this compteted form is inctuded with the DOH approved plans and must be inctuded with the
instatlation instructions and shipped with the unit. lf the completed form has been damaged or lost
during shipping, the manufacturer or its representative can obtain a copy from the DOH.
Before any inspection is scheduted at the on-site location or lnstallation Authorization (required for
modutar homes and mutti-famity structures) is issued by the DOH, this form wi[[ be required to be signed
and dated by the Buitding Official, or Approved Third Party Agent, or Fire Safety Officiat (if appticabte),
and submitted to the DOH.
The DOH approved OC form witt be included with the approved spec file, with the DOH Ptan Reviewer
signature below and their plan approval stamp on the page(s) with the OC listed items to be completed
at the site location. That approved OC form should be submitted to the appropriate parties described in
this form and submitted back to the DOH before any inspection is scheduted at the onsite location or
lnstaltation Authorization (required for modular homes and multi-family structures) is issued.
DOH Ptan Reviewer Na
DOH Ptan Reviewer Signatu
Date Approved-Contact email
Governor Jared S. Polis I Rick M. Garcia, Executive Director I Alison George, Div:s:on Director
jJlJ Sherman St., Room 320, Denver, CO 80203 P 303.864.7810 F 303.864.7857 TDD/TTY 303.864.7758 www.dola.cotorado.gov
5t re ngthe ni ng Co Io r ado Comm uniti e s
Ir
EQUAT HOUSING
o pPoRl uNlrY
ffiffi1 coroRADO
Department of Local At'fairs
Drvision of Housing luLY 2023
Buitding Department Representitive Printed Nam 0
Buitding DePartment Representitive 5ig
Date
-l-L?.?S
'eld \our+y
o
Not Required
K
J 0
l'a
I o\
Fire Safety Official Signature..--- Date
Accept Defer lnspection Contact emai
lf appticabte:
Fire Safety Officiat Printed Nam
Contact emait:*
ls a fire protection system required? (check one) Required
lf required, the inspection is to be performed by (check one):
Fire Department: (NA^4E)-
OR
Colorado Division of Fire Prevention & Controt
Manufacturer's Auihorized Quatity Representative
Printed
Manufacturer' s Authg:ri 4*el resentative
R
{'
Signature
eontact email
lf the inspecti0n has been deferred and the manufactu rer elects to utitize an Approved Third Party
Agenry to inspect the "OC" iterns on behatf of DOH, please sign and date below
Approved Third Party Agent Printed Name,-
U<qfi l*^kuareS. Caa-t
Approved Third Party Agent Signature--,-.=-- Date
Contact em
Governor Jared s. potjs I Rick M, Garcia, Executive Dlrector I Atison 6eorge, Division Director
1313 sherman Sr., Room 320, Denver, c0 80203 p 303.864.7810 F 303.864.7857 TDD/TTY 303'8G.7758 www.dota.colorado.gov
Strength ening Co larodo Communiti e s
rosrfi*
ECIUA llouslNF
OP POSIUNITY
reel COLORADO
Department of Local Affairs
DMsion of Housing IULY 2023
Verify lnspection(s) ComP[eted
Once you have compteted att of your assigned inspections identified in this form and they have passed
for compliance, ptease sign and date betow.
BuitdingDepartmentRepresentitivePrintedName
Buitding Department Representitive Signatu
Contact emai[:-
Or
Approved Third Party Agent Printed Name
Approved Third Party Agent Signature Date-
Contact emai[:-
Fire Protection Systems (if applicaba.') N/A
Fire Safety Officiat Printed
Fire Safety Officiat Signatu
Contact emait:-
Ptease direct questions to manufactured.ptans@state'co.us
6overnor Jared S. Potis I Rick M. Garcia, Executive Director I Alison 6eorge, Divisiorr Director
13'13 Sherman St., Room 320, Denver, C0 80203 P 303.B64.7810 F 303.864.7857 TDD/TTY 303.864.7758 wwttr.dola.colorado.gov
St r engthen i ng Colo rado Communi ti e s
IT
IOUAT HOUSING
OPPORIUNIIT
reg I ffi"1-"-r,tr3*o*"o"IULY 2023
The following is based on information provided to the Division of Housing (DOH) and may be modified
based on the actual findings of the field inspection.
DATE: 5-15-25
MANUFACTuRER: clayton Homes Albuq UerqUe lD No.: 174
CONTACT: Mike Sena, DorthY Heckler pHoNE No.: (505) 242-5580
MoDEL No.: CUSTOM 2776 CONRAD DOH P/A NO
INSPECTION REQUIREMENTS: Check on site:
"OC" lnspection ltems
1. A/C
2. Blower door test per REScheck
3. Completion of the Ridge vents at the marriage line.
Water line inlet connection to utility connections on-site.
5. Waste line outlet connection to utility connections on-site.
6. Gas line inlet connection to utility connections on-site.
7. Electrical system connection to utility connections on-site and crossover connections, smoke and CO alarms, testing, and enerqy
disconnect.
8.Siding & soffit cempanel: to finish offthe section at the marriage line endwalls after home is set.
9. lnstallation of light near crawl space access.
10. All on,site added ducts, air handlers and filter boxes are sealed. Joints and seams shall comply with Sect. M1601 .4'1
1 1. Min. R-8 insulation for ducts outside of conditioned space
12. Mech. ventilation systems tested to meet min. flow rates per Section N1 103.6, using mfr. instructions or airflow measuring devices. As
required, testing completed by and third party/
13. Energy rater, w/ signed report provided to code official. Exception: Kitchen range hoods w/ ducts 6" or larger and no more than one 90-
elbow
14. Ducts shall be pressure tested per ANSI/RESNET/ICC 380 or ASTM E1554, with leakage un der 4 CFM per 100 sq" ft. of conditioned floor
rea, or under 8 CFM if all ducts are within the building thermal envelope
15. Home tested for air leakage, w/ a max. rate of 5.0 air changes per hour or 0.28 CFM per sq. ft. Testing followed ANSI/RESNETACC3Bo,
E779, oTASTM E1827 at0.2" w.g.pressure. 16. As required, testing completed by an approved 3rd party/Energy Rater, w/ signed
report provided to code official.
16. permanent certificate, completed by the builder or approved party, posted in furnace or utility room or another approved location,
out obstructing any labels on the electrical panel
1 7. Completion of the RS402 Colorado Solar Ready Space (if applicable).
18. Completion of the RV502.1 Colorado EV ready Space(if applicable),
19. Home has been designed for an unvented crawl space in accordance with 1408.3.2.2. the contractor must install supply and return
register to provide conditioned air io the crawl space in accordance with 1408.3.2.2. in addition to installation of crawl space registers it is
the contractors responsibility to insulate the foundation walls with a continuous r-20 insulation, and to cover exposed earth with a
continuous class i vapor retarder per 1408.3 with alljoists sealed with overlap by 6" and shall extend at least 6" up the foundation wall and
be attached and sealed to foundation wall. the return air shall not be located in area prohibited by ml602.2.
I
I