Loading...
HomeMy WebLinkAboutDuct Test ReportEEretrJ,Retrotec rCloud Quality Assurance Report lecc Duct Test PASS Your Result: 0.2CFM1100 ft'? (6 CFM * 100 12717 ltl Target<3CFM/100ff Test lnformation Test Name Test Date Export id Company Name Technician Name Technician Email Building lnformation Address Gity State ZiplpostalCode Country Year Gonstructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan SerialNumber Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre-test lndoor Tem perature Pre-test Outdoor Temperatu re Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Volume 44 Roan Creek return 2025-07 -24 1 2:33 PM (MDT) GWCFgZYO Elite Energy Concepts Coltan Gechter coltan @el iteenergyconcepts. com 44 Roan Creek Parachute Colorado 81 635 United States Not available 5000 ft No Your location has not been validated Tester location not verified Not available Retrotec 300 3XLFTOO7O,1 Retrotec DM32 104 415340 80'F 84'F 9 MPH 102.2kPa 2717 fr 20000 ft" 1 Eretrlr Retrotec rGloud Test Notes No notes entered Flow Equation Parameters - Factory Default Fan Model Retrotec 300 Fan Serial Number 3X1FT00701 Flow Equation Parameters - Bl Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self-referenced fan orwhen the room pressure is negative. lf using a fan which is not self-referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. lf PrA is greater than 0 or fan is self-referencing: FP = lPrBl - PrA lf PrA is less than 0 or fan is self-referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x lRPl) FP = fan RP = room ressure Range Open 74 47 29 18 11 7 102 N 0.5010 0.5045 0.5000 0.5020 0.4990 0.4800 0.5000 0.5900 K 28.9100 7.0770 3.2410 1 .'1900 0.4570 0.2080 0.0718 10.7000 K1 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 K2 0.4000 0.2500 0.1 000 0.2000 0.2500 0.2500 0.1 1 00 0.4000 K3 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 K4 1 I 1 1 I 1 1 1 MF 20 15 10 20 25 25 25 100 flow =FP-RPxK1 X K+K3x xK4 3