Loading...
HomeMy WebLinkAboutObservation of Excavation 04.29.2025I (+A $;,ffii'Ttrtrtr1'"'rd*' *5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email : kaglerrwood@kumarusa.com An Emdoyct O{mtd Compony www'kumarusa'com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado Aprll29,2025 Coiorado Energy Systems Attn: Ian Moritz 27 4 Mountain Shadows Drive Glenwood Springs, Colorado 81601 ian@coloradoenergysystems. com Project No. 25-7-281 Subject: Observation of Excavation, Proposed Second Story Addition,274 Mountain Shadows Drive, Glenwood Springs, Colorado Dear lan: ,{s requested, a representative of Kumar & Associates observed the excavation at the subject site o;r dpril 18, 202.5 to evaluate the soils exposed for foundation support. The findings of our *bser,'ations arrd recommendations for the foundation support are presented in this repod. The seivices were per{bnned in accordance with our agreement for professional engineering services trr Ccrioraclo Energy Systems dated April t5,2025. T'he secocd story addition is proposed to be supported on two isolated footing pads sized for an a.lJowabie bearing pressure of 1,600 psf. The addition will not have ground level development belorv and r,o,'ill be supported on structural steel and wood elements. Ar t-he tiine of our visit to the site, two pad excavations had each been cut to between 3 and 3). feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of firm, sandy clay and gravel. Results of swell-consolidation testing performed on a sample taken lrorn the site, shown on Figure 1, indicate the soils have low to moderate c;cmpressibility under conditi<-rns of loading and wetting. The results of a gradation analysis pei'formed on a sample of sandy clay and gravel (minus 3-inch fraction) obtained fiom the site are presented on Figure 2. No free water was encountered in the excavation and the soils were slightly moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,600 psf should be adequate for support of the proposed addition. The exposed soils tend to compress when wetted and there could be some post-construction settlement of the foundation especially if the bearing soils become wet. Footings should be a minimum width of 2 feet for columns. Loose and disturbed soils in footing areas should be removed and the exposed soils moistened and compacted. Exterior footings should be provided wirh adequate soil cover above their bearing elevations for frost protection. Backfill should be compacted and the surface graded to drain away from the new pads. Colorado Energy Systems Apri|29,2025 Page2 The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If you have any questions or need further assistance, please call our office. Sincerely, Wasmay &. &*a*aia\w%, t{,c, James H. Parsons, Rev. by: SLP JHFlkac attachments Figure 1 - Swell Consolidation Test Results Figure 2 - Gradation Test Results Kumar & Associates, lnc. o Project No. 25-7-281 SAMPLE OF: Sondy Cloy ond Grovel FROM: Footing Grode - Eosl Pod WC = 1 5.3 %, DD = 105 pcf ( innot be Gproducod, te8ted. Ths NO MOVEMENT UPON WETTING 1 JJ LrJ a I z.o F o =o6z. C)o 0 -l -2 -3 -4 -5 -6 1.0 APPLIED PRESSURE - KSF t0 100 25-7 -281 Kumar & Associates SWELL_CONSOLIDATION TEST RTSULTS Fig. 1 I I u ! ,6.8 R4 100 90 ao 70 60 50 10 20 to o o l0 20 50 40 50 6o 70 ao 90 too tr 2.O IN MILLIMETERS 152 DIAMETER OF PA CLAY TO SILT COBBLES GRAVEL 33 % SAND 23 LIQUID LIMIT SAMPI.E OF: Sondy Cloy ond Grovel % PLASTICITY INDEX SILT AND CLAY 44% FROM: Fooling Grode - East Pod lhoso tesl rEsulls opply only lo lh6 somplos whlch werE l6sl€d. The trsllng roporl sholl nol bs reproduced, €xcept ln lull, wllhoul lho wrlll€n qpprovol of Kumor & Assoclol.s, lno. Sl€vo onolysis l6sling ls psrformed in occordonco wlth ASTM D6913, ASTM D7928, ASTM Cl56 ondlor ASTM Dl140. HYDROMETER ANALYSIS SIEVE ANALYSIS TIME READINES 24 HRS 7 HRS Ittltt I SAND GRAVEL FIN E MEDTUM lCOlnSr FINE COARSE 25-7 -281 Kumar & Associates GRADATION TIST RESULTS Fig. 2