Loading...
HomeMy WebLinkAboutOWTS Permit Card Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: Lot 21, Mountain Springs Ranch, Glenwood Springs Parcel No.: _218529300109 Owner Name: Timothy Banghart Owner Phone: (402) 657-9393 Designed By: CBO, Inc. Designer Phone: (970) 309-5259 Contractor: Boulder Construction Services, LLC Contractor Phone: (970) 456-2676 Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 692.3 ft2 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number _SEPT-9319______________________________ Permit Type X New X Repair X Remodel/addition X Tank only Issue Date _07/31/2025____________________ Expiration Date_07/31/2026_________________ Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by CBO, Inc. dated May 21, 2025. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new three-bedroom residence. The new OWTS components will consist of a new 1,000- gallon two compartment septic tank on the CDPHE approved list followed by a single compartment 500-gallon pump, set level with access to grade. A new screened high-head pump will be housed in the pump chamber. An effluent filter will be installed in the outlet tee of the 1,000-gallon septic tank. Effluent will be dosed from the pump chamber to an Automatic Distributing Valva (ADV) set at the high point of the system to distribute effluent to 700 ft2 of STA. The new STA will consist of a two 10 ft by 35 ft unlined sand filter beds, consisting of at least 3 feet of secondary sand media overlain by perforated distribution laterals placed in GeoMat distribution media. Distribution laterals are to be 1 ½ inch Schedule 40 PVC, with 5/32-inch orifices every 3-feet on center facing downwards with orifice shields. Each lateral is to end in a flushing valve at the distal end. The residual head (squirt height) at the end of the system is to be 5-feet. The infiltrative surface shall be no deeper than 1-foot below natural grade and final cover will be mounded to reach approximately 3 ft of soil over the distribution laterals and sloped at a 3:1 ratio from the top of the mound to the native grade. Inspection ports are to be installed at each corner of each bed. Maintain all setbacks and elevations as designed. To assist in scheduling, please contact Garfield County Public Health (970-945-6614 ext. 8150) to notify the start of OWTS construction. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection, and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 07/31/2025 Issued By: Garfield County Environmental Health Department Date