HomeMy WebLinkAboutCompression Strength 5Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
21-1 7 08/24/24 2 / 5 4.00 12.57 63,052 5,020 3 N
Test Age Average Strengths (psi): 7 Day - 5020
Tested By: Thomas Downing (1)
Checked In : 08/19/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:21
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:30 / 8872
Contractor:RMS
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/17/24
Sampled From:Chute
Placement Method:Pump
Sample Details
Batched:09:33 MDT
Sampled:10:10 MDT
Cast:10:25 MDT
Truck Empty:
Placement Time:
Placement Location:Slab on Grade
Location Details:Bldg. C SOG. East half.
Sample Location / Notes:350 of 390 yards
Batch Log
Strength:4000 (psi)
Specifications
Supplier:United Companies Mix Design:36610709
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.5 (lb/ft³)
Air Content:1.8
Load Volume:10.00 (yd³)
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):83
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 133567
08/17/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
21-1 7 08/24/24 2 / 5 4.00 12.57 63,052 5,020 3 N
21-2 30 09/16/24 2 / 28 4.00 12.57 85,011 6,760 3 C4 N
21-3 30 09/16/24 2 / 28 4.00 12.57 84,416 6,720 4 C4 N
21-4 30 09/16/24 2 / 28 4.00 12.57 88,370 7,030 4 C4 N
21-5 30 09/16/24 2 / 28
Test Age Average Strengths (psi): 7 Day - 5020, 30 Day - 6840
C4: Strength is greater than or equal to f'c.
Tested By: Thomas Downing (1), Ryan Peskuski (2,3,4,5)
Checked In : 08/19/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:21
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:30 / 8872
Contractor:RMS
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/17/24
Sampled From:Chute
Placement Method:Pump
Sample Details
Batched:09:33 MDT
Sampled:10:10 MDT
Cast:10:25 MDT
Truck Empty:
Placement Time:
Placement Location:Slab on Grade
Location Details:Bldg. C SOG. East half.
Sample Location / Notes:350 of 390 yards
Batch Log
Strength:4000 (psi)
Specifications
Supplier:United Companies Mix Design:36610709
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.5 (lb/ft³)
Air Content:1.8
Load Volume:10.00 (yd³)
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):83
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 133567
08/17/2024
Report #: CC-000021
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
22-1 7 09/03/24 1 / 6 4.00 12.57 50,266 4,000 3 N
Test Age Average Strengths (psi): 7 Day - 4000
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:22
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:55 / 1687
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:07:30 MDT
Cast:07:45 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Section of South Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.7 (lb/ft³)
Air Content:1.6
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):64
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134082
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
22-1 7 09/03/24 1 / 6 4.00 12.57 50,266 4,000 3 N
22-2 28 09/24/24 1 / 27 4.00 12.57 65,582 5,220 3 C4 N
22-3 28 09/24/24 1 / 27 4.00 12.57 74,045 5,890 3 C4 N
22-4 28 09/24/24 1 / 27 4.00 12.57 70,631 5,620 3 C4 N
22-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 4000, 28 Day - 5580
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:22
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:55 / 1687
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:07:30 MDT
Cast:07:45 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Section of South Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.7 (lb/ft³)
Air Content:1.6
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):64
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134082
08/27/2024
Report #: CC-000022
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
23-1 7 09/03/24 1 / 6 4.00 12.57 51,314 4,080 3 N
Test Age Average Strengths (psi): 7 Day - 4080
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:23
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:44 / 1693
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:08:45 MDT
Cast:09:00 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining South Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:146.2 (lb/ft³)
Air Content:1.9
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):66
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134083
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
23-1 7 09/03/24 1 / 6 4.00 12.57 51,314 4,080 3 N
23-2 28 09/24/24 1 / 27 4.00 12.57 69,985 5,570 3 C4 N
23-3 28 09/24/24 1 / 27 4.00 12.57 62,917 5,010 3 C4 N
23-4 28 09/24/24 1 / 27 4.00 12.57 66,800 5,310 3 C4 N
23-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 4080, 28 Day - 5300
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:23
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:44 / 1693
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:08:45 MDT
Cast:09:00 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining South Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:146.2 (lb/ft³)
Air Content:1.9
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):66
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134083
08/27/2024
Report #: CC-000023
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
24-1 7 09/03/24 1 / 6 4.00 12.57 46,283 3,680 3 N
Test Age Average Strengths (psi): 7 Day - 3680
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:24
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:60 / 1698
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:10:30 MDT
Cast:10:45 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam on South side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.9 (lb/ft³)
Air Content:1.7
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):69
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134084
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
24-1 7 09/03/24 1 / 6 4.00 12.57 46,283 3,680 3 N
24-2 28 09/24/24 1 / 27 4.00 12.57 60,280 4,800 3 C4 N
24-3 28 09/24/24 1 / 27 4.00 12.57 68,357 5,440 3 C4 N
24-4 28 09/24/24 1 / 27 4.00 12.57 69,132 5,500 3 C4 N
24-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 3680, 28 Day - 5250
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:24
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:60 / 1698
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:10:30 MDT
Cast:10:45 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam on South side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.9 (lb/ft³)
Air Content:1.7
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):69
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134084
08/27/2024
Report #: CC-000024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
25-1 7 09/03/24 1 / 6 4.00 12.57 50,888 4,050 3 N
Test Age Average Strengths (psi): 7 Day - 4050
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:25
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:11:50 MDT
Cast:12:05 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam South Side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.1 (lb/ft³)
Air Content:2.0
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):80
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134085
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
25-1 7 09/03/24 1 / 6 4.00 12.57 50,888 4,050 3 N
25-2 28 09/24/24 1 / 27 4.00 12.57 71,370 5,680 3 C4 N
25-3 28 09/24/24 1 / 27 4.00 12.57 66,873 5,320 3 C4 N
25-4 28 09/24/24 1 / 27 4.00 12.57 64,462 5,130 3 C4 N
25-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 4050, 28 Day - 5380
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:25
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:11:50 MDT
Cast:12:05 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam South Side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.1 (lb/ft³)
Air Content:2.0
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):80
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134085
08/27/2024
Report #: CC-000025
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
26-1 7 09/03/24 1 / 6 4.00 12.57 48,672 3,870 3 N
Test Age Average Strengths (psi): 7 Day - 3870
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:26
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:51 / 0843
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:12:50 MDT
Cast:13:05 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:South Side of Remaining Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.5 (lb/ft³)
Air Content:1.8
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):82
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134086
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
26-1 7 09/03/24 1 / 6 4.00 12.57 48,672 3,870 3 N
26-2 28 09/24/24 1 / 27 4.00 12.57 68,302 5,430 3 C4 N
26-3 28 09/24/24 1 / 27 4.00 12.57 62,407 4,970 3 C4 N
26-4 28 09/24/24 1 / 27 4.00 12.57 62,013 4,930 3 C4 N
26-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 3870, 28 Day - 5110
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:26
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:51 / 0843
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:12:50 MDT
Cast:13:05 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:South Side of Remaining Grade Beam
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:145.5 (lb/ft³)
Air Content:1.8
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):82
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134086
08/27/2024
Report #: CC-000026
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
27-1 7 09/03/24 1 / 6 4.00 12.57 47,054 3,740 4 N
Test Age Average Strengths (psi): 7 Day - 3740
Tested By: Sandon Thibault (1)
Checked In : 08/28/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:27
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:31 / 1823
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:14:05 MDT
Cast:14:20 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam On South Side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:
Air Content:1.0
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134087
08/27/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/13/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
27-1 7 09/03/24 1 / 6 4.00 12.57 47,054 3,740 4 N
27-2 28 09/24/24 1 / 27 4.00 12.57 60,928 4,850 3 C4 N
27-3 28 09/24/24 1 / 27 4.00 12.57 64,196 5,110 3 C4 N
27-4 28 09/24/24 1 / 27 4.00 12.57 55,988 4,450 3 C4 N
27-5 28 09/24/24 1 / 27
Test Age Average Strengths (psi): 7 Day - 3740, 28 Day - 4800
C4: Strength is greater than or equal to f'c.
Tested By: Sandon Thibault (1), Thomas Downing (2,3,4,5)
Checked In : 08/28/2024 (1,2,3,4,5)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:27
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:31 / 1823
Contractor:
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:08/27/24
Sampled From:Mixer
Placement Method:
Sample Details
Batched:
Sampled:14:05 MDT
Cast:14:20 MDT
Truck Empty:
Placement Time:
Placement Location:Various
Location Details:South Half SOG Building A and
Sample Location / Notes:Remaining Grade Beam On South Side
Batch Log
Strength:4000 (psi)
Specifications
Supplier:Casey Concrete
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:
Air Content:1.0
Load Volume:
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39
Sample: 134087
08/27/2024
Report #: CC-000027
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024
Specimen
Number
Test
Age Days
Test
Date
Field / Lab
Cure Days
Average Cylinder
Diameter (in)
Cylinder
Area (in²)
Max Load
(lbs)
Strength
(psi)
Fracture
Type
Break
Remark
Capping
Method
28-1 7 09/16/24 1 / 6 4.00 12.57 59,526 4,740 3 N
Test Age Average Strengths (psi): 7 Day - 4740
Tested By: Ryan Peskuski (1)
Checked In : 09/10/2024 (1)
Capping Methods
N: Unbonded Caps (ASTM C1231)
Set #:28
Specimen Size:4" X 8"
Specimens In Set:5
Truck / Ticket #:54 / 2010
Contractor:Ashley Concrete
Technician:Peskuski, Ryan
Cast By:Peskuski, Ryan
Date Cast:09/09/24
Sampled From:Chute
Placement Method:Pump
Sample Details
Batched:06:50 MDT
Sampled:08:00 MDT
Cast:08:15 MDT
Truck Empty:
Placement Time:
Placement Location:Slab on Deck
Location Details:Bldg. A second level SOD. Northwest quadrant.
Sample Location / Notes:50 of 130+ yards
Batch Log
Strength:4000 (psi)
Specifications
Supplier:United Companies Mix Design:4500 psi ´No A.E.
On-Site Admixtures: None
Location
Standard Cure Field Cure
Field Measurements
Plastic Unit Weight:146.1 (lb/ft³)
Air Content:1.6
Load Volume:10.00 (yd³)
Weather:Consistency:Slump
Air Temperature (F):Concrete Temp (F):70
Lab Test Results
Testing Lab: Glenwood Springs, 234 Center Drive, Glenwood Springs, CO, 81601
General Remarks
Notified contractor of physical property results. Reviewed by RB.
Test results relate only to the sample tested.
Cylinders received in good condition unless noted otherwise. Physical properties of concrete (ASTM C143, C231, C138, C1064).
This Report should not be reproduced, except in full, without the prior authorization of CTL|Thompson Inc.
Page 1 of 1
Client:
Andover Management Group
Louisville, KY 40202
333 East main Street
Suite 300
Project:
214 Center Drive
GS06693.001F-365
Garfield County, CO
214 Center Drive
Compressive Strength of Concrete
Test Method: ASTM C 39 Sample: 134462
09/09/2024
Glenwood Springs
234 Center Drive
Glenwood Springs, CO 81601
Phone: 970-945-2809
Report Date: 09/27/2024