Envelope Gompl iance Gertificate
Project lnformation
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Vertical Glazing / Wall Area:
Permit No.
Performance Sim. Specs:
Construction Site:
Rifle Garfield County Airport (RlL)
Rifle, Colorado 81650
Building Area
90.1 (2016) Standard
Vantage Aviation RIL - 4546
Rifle, Colorado
5b
New Construction
6o/o
BLCO-06-25-9330
EnergyPl us 8. 1.0.009 ( E PW : USA_CO_G ra nd.J u nction-
Wa I ker. Field .T 247 60 _TMY3. epw)
Owner/Agent:
Kyle Cassidy
Vantage Aviation
228 Park Ave S, PMB 73997
New York, New York 10003
949-70t-0759
kcassidy@vantagea ir.com
Designer/Contractor:
Dave Leopold
VJS / Haselden, Vantage Aviation, a
Joint Venture
6950 S. Potomac
Centennial, Colorado 80112
720-450-6473
DaveLeopold@haselden.com
Floor Area
1-FBO (Office) : Nonresidential
2-HANGAR (Transportation) : Nonresidential
6685
39128
Envelope Assemblies
Assembly Gross Area Cavity Gont.or R.Value R-Value
Perimeter
Proposed
U-Factor
Budget U-
Factonur
Roof: Other Metal Building Roof, IBldg, Use 2 - HANGAR] (b)
Floor: Unheated Slab-On-Grade, Vertical 2 ft., IBldg. Use 2 -
HANGAR] (d)
Roof: lnsulation Entirely Above Deck, [Bldg. Use ]. - FBOI
Floor: Unheated Slab-On-Grade, Vertical 2 ft., IBldg. Use ]. -
FBot (d)
NORTH
N.VM (PEMB): Other Metal Building Wall, IBldg. Use 2 -
HANGAR] (b)
N.HD: lnsulated Metal, Non-Swinging, [Bldg. Use 2 - HANGAR]
N.GL: Metal Frame: Fixed, Perf. Specs.: Product lD AG45LT
SGSNX6227#2_Clear, SHGC 0.24, VT 0.54, IBldg. Use 2 -
HANGAR] (c)
N.ST-A: Steel-Framed, l-6in. o.c., IBldg. Use ]. - FBOI
N,HM-A: Steel-Framed, L6in. o.c., IBldg. Use 1- FBO]
N.GL-A: Metal Frame: Fixed, Perf. Specs.: Product lD AG45LT
SGSNX6227#2_Clear, SHGC 0.24, VT 0.54, [Bldg. Use 1 -
FBol (c)
N.ST-B: Steel-Framed, L6in. o,c., IBldg. Use 1 - FBO]
N,HM-B: Steel-Framed, L6in. o.c,, IBldg, Use 1- FBO]
391 28
832
6695
393
9876
6866
180
10.0
30.0
10.0
0.028
0.540
0.032
0.540
0.059
0.300
0.390
0.060
0.060
0.390
0.060
0.060
0.037
0.520
0.032
0.520
0.050
0.310
0.380
0.055
0.055
0.380
0.055
0.055
48
362
161
19.0
19.0
7.5
7.5
258
787
19.0
19.0
7.5
7.5
Project Title: Vantage Aviation RIL - 4546
Data filename:
Report date: 09/05/25
Page 1 of 10
Assembly Gross Area Cavityor R-Value
Perimeter
Cont.
R.Value
Proposed
U-Factor
Budget U-
Factorl"l
N.GL-B: Metal Frame: Fixed, Perf. Specs,: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0,24, VT 0,54, IBldg. Use 1 -
FBol (c)
N.ED-B: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product lD TBD, SHGC 0.24, VT 0.54, [Bldg, Use ].
- FBol (c)
EAST
E.ST: Steel-Framed, 16in. o.c., IBldg. Use 1 - FBO]
E.HM: Steel-Framed, t6in. o,c., IBldg. Use 1 - FBO]
E.GL: Metal Frame: Fixed, Perf. Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0.24, VT 0.54, IBldg, Use 1 -
FBol (c)
E.ST-A: Steel-Framed, L6in. o.c., IBldg. Use 1 - FBO]
E.HM-A: Steel-Framed, L6in, o,c,, IBldg, Use 1- FBO]
E.ED-A: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs,: Product lD TBD, SHGC 0.24, VT 0.54, [Bldg. Use I
- FBol (c)
E.GL-A: Metal Frame: Fixed, Perf. Specs.: Product lD AG45l-T
SGSNX6227#2_Clear, SHGC 0,24, VT 0.54, IBldg. Use 1 -
FBOI (c)
E,VM-B (PEMB): Other Metal Building Wall, IBldg. Use 2 -
HANGAR] (b)
E.WL: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 2 - HANGAR]
E.ST-C: Steel-Framed, 16in. o.c., IBldg. Use ]. - FBOI
SOUTH
S.VM (PEMB): Other Metal Building Wall, IBldg, Use 2 -
HANGAR] (b)
S.GL: Metal Frame: Fixed, Perf. Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0.24, VT 0.54, IBldg. Use 2 -
HANGAR] (c)
S,SD: lnsulated Metal, Swinging, IBldg. Use 2 - HANGAR]
S.OD: lnsulated Metal, Non-Swinging, tBldg. Use 2 - HANGARI
S.WL: Metal Building Wall, Single Layer Mineral Fiber
l^^^^-^--^A ^t ^i*\ IDll^ I l^^ 1 UAf,l-AD I\LVt I lPr EJJEU qL yil (r, l9rUV! VJr z - I t^ttVhl\l
S.HM: Steel-Framed, 16in, o.c., IBldg. Use ]. - FBOI
S,ST: Steel-Framed, 16in. o.c., IBldg. Use 1- FBO]
S.GL.1: Metal Frame: Fixed, Ped. Specs,: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0.24, W 0.54, IBldg. Use L -
FBol (c)
S.HM-A: Steel-Framed, 16in. o,c., IBldg. Use 1- FBO]
S.GL-AI: Metal Frame: Fixed, Perf. Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0.24, VT 0.54, IBldg, Use 1 -
FBOI (c)
S.ST-A: Steel-Framed, L6in. o.c., IBldg. Use 1- FBO]
S.GL-A: Metal Frame: Fixed, Perf, Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0.24, VT 0,54, IBldg. Use 1 -
FBol (c)
WEST
W.ST: Steel-Framed, 16in. o.c., IBldg. Use 1 - FBO]
W.HM: Steel-Framed, L6in. o.c., IBldg. Use 1- - FBO]
W.GL: Metal Frame: Fixed, Perf. Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0,24, VT 0.54, IBldg. Use 1 -
rDUI (L'
W.VM (PEMB): Other Metal Building Wall, [Bldg. Use 2 -
HANGAR] (b)
W,WL: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 2 - HANGAR]
W.HM-A: Steel-Framed, 16in. o.c., IBldg. Use I - FBO]
W.ED-A: Glass (over 50% glazing): Metal l-rame, Entrance
Door, Perf. Specs.: Product lD TBD, SHGC 0.24, VT 0.54, IBldg.
206
45
0.390
0.600
0.060
0.060
0.390
0.060
0.060
0.600
0.390
0.059
1 .'180
0.060
0.059
0.390
0.380
0.170
1.180
0.060
0.060
0.390
0.060
0.390
0.060
0.390
0.060
0.060
0.390
0.059
1.180
0.060
0.600
0.380
0.680
0.055
0.055
0.380
27
297
79
761
1236
698
15
31 33
9B
33
9805
252
0.055
0.055
0.680
19.0
19.0
7.5
7.5
19.0
19.0
7.5
7.5
0.0
19.0
284
t20
76
348
86
394
45
48
410
168
0.370
0.310
0.0500.0
19.0
19.0
0.0
19.0
19.0 7.5
19.0 7 .5
0.0
7.5
0.0
7.5
7.5
0.0
7.5
0.380
0.050
0.050
0.055
0.050
0.380
0.055
0.055
0.380
0.055
0.380
0.055
0.380
0.055
0.055
0.380
0.050
0.050
0.055
0.680
31
313
108
5883
81
19.0
19.0
7.5
7.5
249
90
Vantage Aviation RIL - A546Project Title:
Data filename
Report date: 09/05/25
Page 2 of 10
Assembly Gross Area Cavityor R-Value
Perimeter
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factorr"l
UseL-FBOI(c)
W,GL-A: Metal Frame: Fixed, Perf, Specs.: Product lD AG451T
SGSNX6227#2_Clear, SHGC 0,24, VT 0.54, IBldg, Use L -
FBOI (c)
W.ST-B: Steel-Framed, 16in. o.c., [Bldg. Use 1 - FBO]
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) 'Other' components require supporting documentation for proposed U-factors.
(c) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d) Slab-On-Grade proposed and budget U-factors shown in table are F-factors'
Envelope Compliance Statement
Compliance Staternenil The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 90.1 (2016) Standard requirements in CoMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the lnspection Checklist.
Hauser Architects, P.C. /s/ Hauser Architects, P.C. 9'5'2025
me-Signature Date
30
21 19.0 7 .5
0.390
0.060
0.380
0.055
Envelope PASSES: Design Lyo better than code
Project Title: Vantage Aviation RIL - 4546
Data filename:
Report date: 09/05/25
Page 3 of 10
COMch eck Software Version COMcheckWeb
lnspection Checklist
Energy Code: 90.1 (2016) Standard
Requirements: 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Additional Comments/Assumptions :
Section
#
& Req.lD
Plan Review Complies?Comments/Assumptions
4,2.2,
5.4,3.1.1,
5.7
lPR1l1
i Plans and/or specifications provide
I information with which compliance
jcan be determined for the building
lenvelope and document where
i exceptions to the standard are
tclaimed.
EDoes Not
ENot Observable
ENot npplicable
all iEComplies
4.2.2,
8.4.1.1,
8.4.1.2,
8,7
lPR6l2
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the electrical systems
and equipment and document where
exceptions are claimed, Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
EComplies
EDoes Not
ENot Observable
lNot Applicable
nonrefrigerated warehouse),
gymnasium, fitness/exercise area,
playing area, gymnasium seating
area, convention exhibit/event space,
courtroom, automotive service, fire
station engine room, manufacturing
corridor/transition and bay areas,
retail, library reading and stack areas,
distribution/sorting area,
transportation baggage and seating
areas, or workshop, the following
requirements apply: The daylight zone
under skylights is >= half the floor
area and (a) the skylight area to
daylight zone is >= 3 percent with a
skylight W >= 0.40 or (b) the
minimum skylight effective aperture
>= 1 percent. The skylights have a
measured haze value > 90 percent.
3.5.4.2.3
lPR7l2
lrr buildirrgs > 2,5oo ft2, any encloscd ;flComplies
spaces directly under a roof with :nDoes Not
ceiling heights > 1.5 ft. and used as an -., , ^,otricel roufy, arrium, .oniir-oil -- - l=I"i observable
corridbr, storage (including lLlNot Applicable
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Project Title: Vantage Aviation RIL - 45A6
Data filename:
Report date: 09/05/25
Page 4 of 10
Field Verified
Value Complies?Comments/Assumptions
Section
#
c neci.to
Footing / Foundation
lnspection
Plans Verified
Value
, lnstalled below-grade wall
;insulation type and R-value
I consistent with insulation
ispecifications reported in plans
:and COMcheck reports.
i[lcomplies
iEooes ttot
iEtrtot observable
iEruot Rpplicable
iSee the Envelope Assemblies
itable for values.
R-R-4.2.4
lFol12
lnstalled slab-on-grade insulation
type and R-value consistent with
insulation specifications reported
in plans and COMcheck reports,
R-_
! Unheated
! Heated
EDoes Not
ENot Observable
ENot Applicable
See the Envelope Assemblies
table for values.
R-lies4.2.4
lFo3l2 ! Unheated
! Heated
EDoes Not
!Not Observable
nNot Applicable
lies5.8.1.2
lFo4l2
Slab edge insulation installed per
manufacturer's instructions.
EComplies
EDoes Not
ENot Observable
[JNot applicable
ft ft see the Envelope Assemblies
table for values.
5.5.3.5
lFo5l2
Slab edge insulation
depth/length,
i Exterior insulation protected
,against damage, sunlight,
imoisture, wind, landscaping and
i equipment maintenance
iactivities.
ilComplies
EDoes Not
ENot Observable
[JNot Applicable
5,8,1.7
lFo6li
lnsulation in contact with the
ground has <=0.37o water
absorption rate per ASTM C272
,[lComplies
EDoes Not
ENot Observable
,!Not Applicable
5.8.1.7.3
lFo7l1
Bottom surface of floor structures
incorporating radiant heating
insulated to >=R-3.5.
lComplies
EDoes Not
ENot Observable
iSee the Envelope Assemblies
:table for values.
R-R-
;nNot Applicable
6.4.4.L.5
lFo11l3
Additional Comments/Assumptions:
2 Medium lmpact (Tier 2)3 LoW I (Tier 3)1 High (Tier 1)
Vantage Aviation RIL - 4546Project Title:
Data filename
Report date: 09/05/25
Page 5 of 10
Section
#
& Req.lD
Framing / Rough-ln lnspection Plans Verified
Value
Field Verified
Value Complies?Comments/Assumptions
i Factory-built and site-assembled
fenestration and doors are
:labeled or certified as meeting air
leakage requirements.
flComplies
nDoes Not
ENot Observable
Eruot npplicable
5.4.3.2
lFRl13
Vestibules are installed where
building entrances separate
corrditioned space froln the
exterior, and meet exterior
envelope requirements. Doors
have self-closing devices, and are
,>=7 ft apart (>= 1"6 ft apart for
adjoinging floor area >= 40000
:sq.ft.). Vestibule floor area <=7
!50 sq,ft. or 2 percent of the
, adioining conditioned floor area.
5.4.3.4
lFR4ls
EComplies
EDoes Not
!Not observable
flruot npplicable
5.5.4.3a Verticalfenestration U-Factor
lFR8ll
lComplies See the Envelope Assemblies
EDoes Not table for values.
ENot Observable
lNot Applicable
U-U-
nComplies'EDoes Not
ENot Observable
tENot Applicable
See the Envelope Assemblies
',table for values.
i
Skylight fenestration U-Factor U-U-5.5.4.3b
lFR9lr
5.5.4.4,L 'Vertical fenestration SHGC value
lFR10l1
rEComplies
:EDoes Not
:ENot Observable
Eruot applicable
SH GC:SH GC::See the Envelope Assemblies
'table for values.
EComplies
EDoes Not
ENot Observable
ENot Applicable
rSee the Envelope Assemblies, Skylight SHGC value.
table for values.
SHGC: SHGC:5,5.4.4.2
lFR11l1
5.8.2.L,
5.8.2.3,
5.8.2.4,
5.8.2.5
tFRl2l'
EComplies
EDoes Not
INot Observable
LNot Applicable
; Fenestration products rated (U-
,factor, SHGC, and W) in
accordance with NfRC or energy
code defaults are used.
: Fenestration and door products
are labeled, or a signed and
,dated certificate listing the U-
,factor, SHGC, VT, and air leakage
rate has been provided by tlre
manufacturer.
[Does Not
ENot Observable ,
DNot Applicable
plies5,8,2,2
lFRr.3lt
U-factor of opaque doors
associated with the building
thermal envelope meets
requirements.
'EComplies
:EDoes Not
INot Observable
Et"tot Applicable
U-
! Nonswinging
5.5.3.6
lFR14l2
see the Envelope Assemblies
table for values.! Swinging
! Nonswinging
u-_
! Swinging
Continuous air barrier is
wrapped, sealed, caulked,
gasketed, and/or taped in an
approved manner, except in
semiheated spaces in climate
zones L-6.
flComplies
lDoes Not
ENot Observable
nNot Applicable
5.4.3.1
lFR15l1
Additional Comments/Assu mptions :
1 High lmpact (Tier 1)2 Medium lmpact (Tier 2)3 Low lmpact (Tier 3)
Vantage Aviation RIL - 4546Project Title:
Data filename
Report date: 09/05/25
Page 6 of 10
Comments/Assumptions
Section
#,
& Reo.lD
Rough-ln Electrical lnspection Complies?
io
;n
an automatic control device.
At least 50o/o of all 125 volt 15- and iDComplies
20-Amp receptacles are controlled by ilOoes ttot
8.4.2
lELlol2
Not Observable
Not Applicable
New buildings have electrical energy
use measurement devices installed,
Where tenant spaces exist, each
tenant is monitored separately. ln
buildings with a digital control system
the energy use is transmitted to to
control system and displayed
Applicable
ENot Observable
Does Not
plies8.4.3
lEL1112
Additional Com ments/Assumptions;
2 Medium (Tier 2)3 Low lmpact (Tier 3)1 lm (Tier 1)Hi
Pro.iect Title: Vantage Aviation RIL - A5A6
Data filename:
Report date: 09/05/25
Page 7 of 10
Section
#
& Reo.lD
Insulation lnspection Complies?Comments/AssumptionsPlans Verified
Value
Field Verified
Value
llnstalled roof insulation type and l
, R-value consistent with insulation
specifications reported in plans i
and COMcheck reports. For some i
ceiling systems, verification may j
need to occur during Framing i,lnspectlon.
i
R-_
: ! nbove deck
! Metal
in Attic
lComplies
EDoes Not
ENot observable
ltrtot Applicable
;See the Envelope Assemblies
,table for values.
l
i
R-4.2.4
ilN211 I Above deck
fl Metal
n Attic
5.8,1,2,
5.8.r.,3
ltN3ll
Roof insulation installed per
, manufacturer's i nstructions.
;Blown or poured loose-fill'insulation is installed only where
EComplies
lDoes Not
f]Not Observable
Eruot applicablethe ceiling is <= 3:12.
: lnstalled above-grade wall
insulation type and R-value
, consistent with insulation
specifications reported in plans
and COMcheck reports.
Mass
Metal
Steel
Wood
nnnn
R-_
! Mass
! Metal
! Steel
! Wood
tICompliesl[Does Not
INot Observable:nNot Applicable
R-4.2.4
ltN6ll
lSee the Envelope Assemblies
',table for values.
Above-grade wall insulation
installed per rnanufacturer's
instructions,
nComplies
nDoes Not
ENot Observable
ENot Applicable
5.8.1.2
ltN7ll
,lnstalled floor insulation type and
; R-value consistent with insulation
specifications reported in plans
and COMcheck reports.
R-R-
ntrn
Mass
Steel
Wood
4.2.4
ltN8l2 ! Mass
! Steel
! Wood
nNot obscrvablc
flruot npplicable i
flComplies
flDoes Not
:see fhe Envelope Assemblies
'.table for values.
Building envelope insulation is
,labeled with R-value or insulation i
cerLiticaLe lras beerr provided
listing R-value and other relevant ,
. data.
flComplies
lDoes Not
flNot Observable
flruot npplicable
5.8.1.L
ltNt 0l2
, Building envelope insulation
,extends over the full area of the
: component at the proposed rated
:R or U value.
EComplies
nDoes Not
ENot Observable
!Not Applicable
5.8.1.9
lrN1812
!Complies
flDoes Not
!Not Observable
!Not Applicable
5.8.1.4
ltN1112
Eaves are baffled to deflect air to
above the insulation.
lnsulation is installed in
substantial contact with the
inside surface separating
, conditioned space from
unconditional space.
!Complies
lDoes Not
!Not Observable
!Not Applicable
5,8.1,5
ltN1212
Recessetj equiprnettL irrsl"alled irt
, building envelope assemblies
: does not compress the adjacent
insu lation,
!Currrplies
DDoes Not
ENot Observable
DNot Applicable
5.E.1.6
ltN13l2
Attics and mechanical rooms
have insuiation protecieci where
adjacent to attic or equipment
access,
EComplies
fiDoes Not
flNot Observable
ENot Applicable
5.8.r..7.r.
trN r5l'
1 Hi act (Tier 1)2 Medium lm ct (Tier 2)3 Low lm (Tier 3)
Project Title: Vantage Aviation RIL - 4546
Data filename:
Report date: 09/05/25
Page 8 of 10
4
v€nts d-o nat interbl€
i$rtulptlqn,
l-lComplies
Eooei Not
EINotobr{rrvablb
ENo't'Appfieable
Add.itio nal Go mm'snts/As.umptlonsl
Fmject Ti.tle; Vsntqge Aviatiq.n RIL 1A5.As
Data filename;
R€pnftdater 09105/25
Fdge Iot ro
5.4.3,3
lFnll
Wetther€eals instElled on all
dock cargo doors in CllmateL
,loading.
Zones4'Not
Ob,sorvable
Addltlonal Gommonts/AEEumptlonsr
1 (Tier 1)(Tier 2)Medium (Tier 3)
ProJect Tltle: Vantage Aviation RIL - A5A5
Data fllename:
Report date: 09/05/25
Page 10 of L0