Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-06 -25-9330 VANTAGE AVIATION HANGER LOT 45-6 NEW HANGER WITH DEICING OPERATION GARFI ELD COU NTY AI RPORT 375 COUNTY ROAD 352 1) THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS. 2) SANTTARY FACTLTTTES ARE REOUIRED TO BE PROVIDED FOR WORKERS. 3) A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE IS TO PERMIT AND APPROVE THE ELECTRICAL WORK. HTTPS ://WWW.CO LO RADO.G OV/PACI Fl C/DORA/D PO ELECTRI CAL P LU M B I NG PE RMITS 4) UNDERGROUND UTtLrTy LOCATES tS THE RESPONSIBTLTry OF THE OWNER OR CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE. 5) ALL BACKFLOW PREVENTERS ARE REQUIRED TO BE TESTED AND CERTIFIED BY A LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. 6) SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE CONTACT THE COUNTY PLANNER FOR THE APPLICATION. 7) ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTIONS. 8) THE ELECTRICAL CODE REOUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE STATE ELECTRICAL INSPECTOR IS REOUIRED (303) 869-3458. PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN DOCUMENTATION OF THE INSPECTION. 9) THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION IS APPROVED. 1O)BECAUSE IT FEEDS THE FIRE SPRINKLER SYSTEM, THE NEW WATER LINE SUPPLYING THIS BUILDING IS TO BE INSPECTED BY THE FIRE MARSHAL ALONG WITH THE WATER DISTRICT SUPPLYING THE WATER PRIOR TO BACKFILLING. 1 1) ANY REQUIREMENTS FROM THE CITY OF RIFLE REGARDING THE WATER AND SEWER INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR. 12)THE ENGTNEER OF RECORD rS TO VIEW THE TNFRASTRUCTURE WORK AND PROVIDE A LETTER OF ACCEPTANCE TO THE COUNTY BUILDING DEPARTMENT 13)PLEASE PROVTDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING DEPARTMENT, WELDING AND BOLTING IS MINIMUM. 14)GEOTECHNICAL OBSERVATION lS REOUIRED WHEN THE EXCAVATION lS COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION, 2500PSF. 15)COMBUSTTBLE MATERTAL rS LTMTTED rN ryPE r AND ryPE il CONSTRUCTTON. SEE IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS. 1 6)ALL EXTERTOR LTGHTING lS TO BE DOWNCAST AND SHIELDED. 17)SAFEry GLAZING IS NOT DESIGNATED ON THE PLANS. SAFEry GLAZING WILL BE cHECKED DURTNG THE FRAMING AND FINAL INSPECTION. (lBC 2406.4) 1B)ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE CONSTRUCTION WILL BE REOUIRED TO BE FIRE-STOPPED WITH LISTED FIRE STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE ASSEMBLTES AT THE FRAMING INSPECTION. (lBC 713) 1 9)A KNOX BOX tS REOUTRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR. PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION. 20)tF THE FtRE SpRtNKLER SYSTEM REOUTRES A FrRE PUMP. THEN THE UTILITY ROOM THAT HOUSES THE PUMP WILL BE REOUIRED TO BE ONE-HOUR CONSTRUCTION. (rBC TABLE s08.2.s) 21)THE LOBBY/FBO AREA WILL BE REQUIRED TO PASS A BLOWER DOOR TEST pRtoR To THE TSSUANCE OF THE CERTIFICATE OF OCCUPANCY. (IECC C402.5) 22)THE WALLS SURROUNDING THE TOILET ARE TO BE NON-ABSORBENT FOR A HEIGHT OF 48'' AND 2' PAST ON EACH SIDE OF THE TOILET. 23)ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP, TNCLUD|NG POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6) 24)GRAB BAR BACKING IS TO BE IN PLACE FOR ALL TOILETS, BATHTUBS AND SHOWERS. 25)pROVtDE MECHANTCAL COMM|SSTONTNG PER 2018 rECC C408. SEE CHECKLIST c408.2.4. 26)ANy EXPOSED FOAM rS TO BE COVERED W|TH AN TGNTTTON BARRIER OR A THERMAL BARRTER BASED ON LOCATION. (lRC R316) 27)THE SLAB EDGE TNUSLATTON tS ALLOWED TO BE REDUCED TO 1" AT THE SLAB ARFA, 28) 12, p201, p202, THE GAS ENTRY |NTO THE BUILDING lS SHOWN lN 3 DIFFERENT LOCATIONS. PLEASE COORDINATE PRIOR TO THE INSTALLATION. VEHICLE PROTECTION MAY BE REQUIRED IF LOCATION IS PER P201. 29)THE HETGHT OF THE HANGER DOOR lS TO BE28',MAXIMUM, THE REMOVEABLE PANEL IS NOT TO BE REMOVED TO INCREASE THE DOOR HEIGHT WITHOUT APPROVAL OF THE BUILDING DEPARTMENT AND THE FIRE DISTRICT. FOAM SUPRESSION IS REOUIRED FOR HANGER DOORS OVER 28'TALL. 30) CALL FOR AN UNDERGROUND PLUMBING INSPECTION OF THE SANDiOTL SEPARATOR PRIOR TO BACKFILLING. 31) EACH LAYER OF THE MULTI-LAYER FIRE-RESISTIVE GYPSUM ASSEMBLIES ARE TO BE CALLED IN FOR INSPECTION, 32)A LOCAL AMENDMENT REQUTRES THE FTREPLACE CHASE TO BE F|RE BLOCKED AT 1O'INTERVALS. 33)ALL MATERIALS IN THE PLENUM ABOVE CEILING SHALL HAVE A MINIMUM FLAME INDEX OF 25 AND SMOKE DEVELOPMENT INDEX OF NOT MORE THAN 50. (rMc 602.2.1) 34)ACCESS PANELS ARE REQUIRED TO SERVICE THE FIRE DAMPERS. 35)M202 - STORAGE ROOM 126 HAS BEEN ADDED SINCE THE ORIGINAL REVIEW. THE RETURN DUCT DOES NOT COMMUNICATE WITH THE AIR HANDLER UNIT. IT APPEARS IT SHOULD BE DUCTED TO THE OFFICE AREA WITH A FIRE DAMPER OR AN OPENING TO CONNECT THE TWO PLENUMS WITH A FIRE DAMPER. PLEASE VERIFY WITH THE DESIGN ENGINEER PRIOR TO INSTALLATION. 36)EMERGENCY LtGHTTNG rS REOUIRED OUTSIDE OF EACH EXlr DOOR.