HomeMy WebLinkAboutMechanical Specs'i--i
PTUMBING
Plumbing:
DRAWING ITEMS
L Drawing P201
a. Sand/oil vent piping and associated keynote added
END OF PLUMBING
Enclosures
ETECTRICAT
Electrical:
DRAWING ITEMS
L Drawing E200
a. (2) Light fixtures, SW3, have been revised to emergency lighting.
END OF ELECTRICAL
Vantage Aviation A5/A6
|MEG # 24005!74.0L Bldg Dept Review L Page 1 of L
i.ri)
MECHANTCAT/ PTUMBTNG
MECHANICAI:
DRAWING ITEMS
t. Drawing M000
a. Sheet index updated
2. Drawing M200
a. Boiler flue and combustion air removed
b. HVLS-1 and HVLS-2 updated
c. HVLS-3 AND HVLS-4 removed
3. Drawing M202
a. Boiler, snowmelt piping, boiler flue and combustion air removed
b. Two exhaust grilles removed in Storage 126
c. Return grille added to Storage 126
d. Exhaust grille shifted to be located in Janitor 119
4. Drawing M205
a. Sheet removed
5. Drawing M211
a. Sheet removed
6. Drawing M401
a. Snowmelt details removed
7. Drawing M402
a. Sheet removed
8. Drawing M403
a. Sheet removed
9. Drawing M600
a. Ceiling fan schedule update
10. Drawing M601
a. Pipe insulation schedule updated
11. Drawing M602
a. Boiler schedule, pump schedule, and snowmelt schedule removed
PLUMBING:
DRAWING ITEMS
L Drawing P202
a. Sanitary piping removed
b. Sanitary piping serving floor sink added
2. Drawing P203
a. Restroom removed, fixtures removed, CW, HW, HWC and vent piping removed
b. Floor sink and associated keynote added
c. Utility box serving new ice maker and associated keynote added
3. Drawing P400
a. lce maker detail added
4. Drawing P401
a. Sanitary isometric updated
5. Drawing P404
a. Gas isometric updated where snowmelt boilers were removed.
Vantage Aviation 45/46
|MEG # 24005774.0t cB 01 Page L of 2
6. Drawing P600
a. Natural gas pressure reducing valve schedule rrpdated
7. Drawing P601
a. Floor sink added to Plumbing Material List
b. UB-2 added to Plumbing Material List
END OF MECHANICAL / PLUMBING
ETECTRICAT
E[ECTRICAt:
DRAWING ITEMS
1. Drawlng E203
a. Big Ass Fans count reduced from four to two.
2. Drawing E204
a. Line Service 114 - lce machine location adjusted
b. Line Service 114 - Refrigerator location adjusted
c. Line Service 114 - (1) above counter receptacle removed
d. Storage 126 - Location ofvisual fire alarm device adjusted
e. Storage 126 - Mounting height of receptacle adjusted to standard height3. Drawing E-500
a. Feeders for MSD, MDPAS, all branch panels, and all transformers adjusted to aluminum (see
specifications for more information).
4. Drawing E700
a. Panel "H2A5", circuits 2,3,4,6,8,!O,L2,L4,L6,!8,20,22,24,26,28,30 have been adjusted according to
new loads for Big Ass Fans.
SPECIFICATION ITEMS
L. Section 26 05 00 - Basic Electrical Requirements
a. Lightning Protection has been removed.
2. Section 26 05 13 - Wire and Cable
a. Aluminum feeder requirements and specifications have been added3. Section 26 05 26 - Grounding and Bonding
a. Lightning Protection has been removed.
END OF ELECTRICAL
Vantage Aviation A5/A6
|MEG # 24005L74.O7 cB 01 Page 2 of 2
PTUMBING
Plumbing:
DRAWING ITEMS
l. Drawing P200
a. Sand/oil vent piping added
2. Drawing P201
a. Sand/oil vent piping and associated keynote added
END OF PLUMBING
Enclosures
ETECTRICAT
Electrical:
DRAWING ITEMS
t. Drawing E200
a. (5) Lieht fixtures have been revised to emergency lighting.
2. Drawing E201
a. (L) Lieht fixture has been revised to emergency lighting.
3. Drawing E202
a. Emergency Lighting has been adjusted in vestibules
b. (1) Light fixture has been revised to emergency lighting in Corridor 116.
4. Drawing 8202
a. Keynote #6 has been added to clarify intent of washer and dryer in Janitor 119.
5. Drawing E600
a. Light fixtures SD1E and SW1E have been added to luminaire schedule for emergency lighting. Fixtures
are the same as SDl and SW1, except with emergency battery packs included.
END OF ELECTRICAL
Vantage Aviation 45/46
rMEG # 24005L74.0L Bldg Dept Review 1 Page 1 of 1
PEAK
ENGINEERINGX
CONSUTTING STRUCTURAL ENGINEERING
August 29,2025
Vantage Aviation A5-6
Peak No. 24-116.00
Construction Bulletin 01
STRUCTURAL NARRATIVE OF CHANGES:
Sheet 51.1 : added hangar collateral load note
Modified notes 3.A and 3.D
Removed note 3.E and renumbered
Modified note 4.1
Modified note 6.A
Sheet 51.2: none
Sheet 51.3: none
Sheet 51.4: none
Sheet 51.5: modified detail 4/S1.5
Sheet S2.0: modified Net Wind Uplift on Joist and Joist Girders detail
Sheet S2.1: stretched WF270 5'-0" beyond gridline 1
Added section cut 4/53.2
Stretched WF270 2''0" beyond gridline 11
Sheet $2.2: changed column type at grids 2.8-EE, 0.1-EE, 4.6-EE, 0.1-AA
Added column tyPes 7 and 8
Modified column base plate on column type 4
Sheet S2.3: updated various beam sizes
Updated various beam reactions
Added section cut at 6.6-CC
Sheet 52.4: updated beam sizes along grid 0.1
Added axial load not to beams along grid DD.S and AA'9
Updated beam size and reaction along grid 6.5
D PEAK
ENGINEERINGY
390 Union Boulcvard, Suitc 500, Lakewood, Colorado 80228
main: 303 274 0707 | fax: 303 274 0808 | www.PeakEngr.com
Sheet S3.1: dimensions added to various detaits
Bars in detail 7ls3.1updated from #5 to#4
Modified detail 6/S3.1
Detail 9/S3.1 moved to sheet S3.3
Various updates to Anchor Rod/Pilaster Schedule - A, and notes below
Sheet S3.2: modified detail 1153.2
Modified detail 2lSZ.2
Added detail 4153.2
Various updates to Anchor Rod/Pilaster Schedule - B, and notes below
Sheet S3.3: this sheet added
Sheet S4.1: modified dimension in detail 215.4.1
Modified framing in detail 3/S4.1
Modified detail 4154.1
Modified detail 5/S4.1
Modified plate size on detail 6/S4.1
Modified plate connection on detail TlS4.1
Modified weld and removed shear lug on detail 8/S4.1
Modified framing on detail g/S4.1
Sheet S4.2: none