August 25, 2025
Justin Sanford
Dustin o-rentals.com
129 CAINS LANE
CARBONDALE, CO 81 623
970.309.5259
CARLA.OSTBE RG@G MAI L. CO M
Subsurface Investigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
Lot 33, Rapids on the Colorado
Garfield County, Colorado
Justin,
Project No. C1981
CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 2.0-acre property is located outside of New Castle, in an
area where OWTSs are necessary.
Legal Description: Section: 4 Township: 6 Range: 91 Subdivision: RAPIDS ON THE COLORADO Lot: 33
Parcel ID: 2181-043-07-033
SITE CONDITIONS
The property is currently undeveloped. A 4-bedroom residence is proposed.
The residence will be served by a community water system with the water line entering the property from
the shut off to the north. The water line must be at least 10-feet from the septic tank and at least 25-feet
from the soil treatment area (STA).
The proposed STA location has an approximate 2 to 3 percent slope to the northwest. The proposed
area is vegetated with native grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
SUBSURFACE
The subsurface was investigated on June 23, 2025 by digging two soil profile test pit excavations (Test Pits).
A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.'
The materials encountered in Test Pit #1 consisted of dark brown topsoil to 18-inches, underlain by
medium brown sandy loam to 6.0-feet, underlain by sand and cobbles to a maximum depth explored of
7.0-feet. No bedrock or groundwater was encountered.
The materials encountered in Test Pit #2 consisted of medium brown sandy loam to 2-feet, underlain by
light brown sandy loam to 6.0-feet, underlain by sand and cobbles to a maximum depth explored of 7.0-
' Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 2
feet. No bedrock or groundwater was encountered.
A sample of the soil was taken from Test Pit #1 at 3-feet below grade. Soil structure grade was
moderate. The soil formed a ball and a ribbon less than 1-inch in length before breaking. Soil structure
shape was blocky and consistence was firm to extremely firm. Soil texture was more gritty than smooth.
With sand and cobbles encountered at 6-feet, the infiltrative area can be installed NO DEEPER than 2.0-
feet below grade to assure 4-feet of suitable soils prior to encountering the Type R-0 soils.
The soil is consistent with Soil Type 2, Sandy Loam, with moderate structure grade. A long-term
acceptance rate (LTAR) of 0.6 gallons per square foot will be used to design the STA.
Test Pit #1
Page 3
Test Pit #1, note sand and cobbles below 6-feet
Test Pit #2
Sandy material below 6-feet
-AA
ct
Backfill
Page 4
DESIGN SPECIFICATIONS
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4t" Bedroom) = 525 GPD
LTAR = 0.6 GPD/SF
525 GPD / 0.6 GPD/SF = 875 SF x 1.0 (gravity, trenches) x 0.7 (chambers) = 612.5 SF
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation at grade 5404.75' has been established as
100' (Finished Floor). CBO Inc. should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
OWTS Component
Primary Tank Inlet Invert
Distribution Box
Infiltrative Surface
Minimum Elevation
Approximate horizontal distance 7' / min. 2% fall /
min. 1.75" fall
Approximate horizontal distance 27' / min. 1% fall /
min. 3.375" fall
Approximate horizontal distance 30' to furthest
trench / min. 1 % fall to STA / min. 3.75" fall
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The 4-inch SDR-35 sewer line exiting the residence must have a double -sweep clean out and a minimum
2% grade to the septic tank.
Page 5
The system installation must include a minimum 1250-gallon, two -compartment poly septic tank with an
Orenco® Biotube effluent filter on the outlet tee. We have specified a 1500-gallon, two -compartment
Infiltrator® poly septic tank as they are locally available. Any state -approved concrete or poly septic tank
may be substituted. Risers must bring the manhole lids to grade for access. If more than one riser is
added to the septic tank, an extension handle must be installed on the effluent filter.
Effluent will gravity flow to a distribution box, and then to four gravelless chamber trenches. The
distribution box must be accessible from grade and must have flow equalizers, or similar product,
installed on each outlet pipe in the distribution box to assure equal flow to each trench.
Each trench will consist of 13 `Quick 4' Standard Plus Infiltrator® chambers for a total of 52 chambers
and 624 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each
trench. Inspection ports must be installed at the beginning and end of each trench. Ports may be cut to
grade and placed in sprinkler boxes for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT
Septic Tank
Effluent Filter
Tank Risers and Lids
mbers
MANUFACTURER
Infiltrator®
Orenco®
Orenco®
Polylok
MODEL N
M-1530-2CP
'QUICK 4' Plus 5tanac
Low Profile Chamber
COMMENTS
500-gallon, two-
ompartment poly septic
ink min. 1250-gallons)
" diameter full size filter
)le -walled PVC Risers a
(24" diameter)
istribution box, risers, lid, flow
LLalizers (4
i 'Quick 4' Low Profile
cambers
Construction must be according to the jurisdiction's adopted On -Site Wastewater Treatment System
Regulations, the OWTS Permit, and this design.
PERMIT APPLICATION INSTRUCTIONS
An OWTS Permit Application must be submitted to Garfield County Environmental Health Department.
htt s://www. arfield-count .com/environmental-health/files cco/sites/16/OWTS-Application-Com lete-
Packet-Dec.-2019.Ddf. If the OWTS Permit Application will be submitted with a Building Permit
Application, it should be submitted directly to Garfield County Building Department.
All questions regarding permit submission can be directed to Garfield County Environmental Health
Department, 970-945-6614 x8150.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
Page 6
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
Page 7
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in this report, CBO Inc. should be notified. All OWTS construction must be according to the
county regulations. Requirements not specified in this report must follow applicable county regulations.
The contractor should have documented and demonstrated knowledge of the requirements and
regulations of the county in which they are working. Licensing of Systems Contractors may be required
by county regulation.
Please call with questions.
Sincerely,
CBO Inc.
&X� C O&f&,A�,S
Carla Ostberg, MPH, REHS
R 2.0
Yiew
pills
ane ,0M,� ROPERTY LINE
f ►f _
4-BEDROOM
1 l STA - RESIDENCE I
�_ I ►i n SEPTIC?
TANK
I a
TP 1 ••
i 3
+�-
,2.00 cres
1
• A TP 2
1
t
N '
►
►
►
►
I ►
I �
I THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARE
NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS
1� ARE APPROXIMATE. IT IS THE HOMEOWNERS' DUTY TO ;
ENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONS
ARE ACCURATE. PROPERTY LINES AND SETBACK DISTANCES ;
SHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALED ►
SCALE: 1 - 50'-0" FOR PRINTING ON 11" X 17" PAPER.
DRAWINGS MUST BE USED IN
CONJUNCTION WITH DESIGN
LETTER DATED 08/25/2025
Ci to CBO Inc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla.ostberg@gmail.com
�l SITE PLAN
Spencer Charles Holdings LLC
Lot 33, Rapids on the Colorado
Garfield County, Colorado
Project Number: C1981
1
,
,
,
,
,
,
,
or
WELL
Date: 08/25/2025
W1.0
Designed by: CBO Sheet 1 OF 4
Drawn by: DID
apicz's View
Lane G5 Or PP�M�1 <
e
'QUICK-4' CHAMBER TRENCHES.
4 TRENCHES WITH 13 CHAMBERS PER TRENCH
FOR A TOTAL OF 52 CHAMBERS AND 624 SF.
,..�P
or 5�
of 4" DIA SDR-35 INSPECTION PORT AT �\
BEGINNING AND END OF EACH TRENCH
V \
\
\ �
to i 0
78
\
SCALE: 1 = 20'=0 \
4" DIA SDR-35 SEWER PIPE WITH DOUBLE SWEEP CLEANOUT
MIN 2% FALL TO TANK
n PROPOSED OWTS
1- 20°-1
CBO Inc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla.ostberg@gmail.corn
20' UT1LlT ,, DRAINAGE & IRR/GA77ON EASEMENT
ROPERTY LINE
4" DIA SDR-35 DISTRIBUTION LINE TO EACH TRENCH
(MIN. 1 % SLOPE TO TRENCH)
DISTRIBUTION BOX %WATER SHUT OFF
WITH ACCESS AT GRADE ._ /
4" DIA SDR-35 SEWER LINE TO
STA
(MIN. 1% FALL TO STA)
INIMUM 1250-GALLON,
TWO -COMPARTMENT
SEPTIC TANK WITH EFFLUENT
a SCREEN
O
IN O 5' MIN , 23% 5� C
a �P`
4-BEDROOM
RESIDENCE .
BM 100' =
5404.74'
Spencer Charles Holdings LLC
Lot 33, Rapids on the Colorado
Garfield County, Colorado
Project Number: C1981
0
APPROX. WATER LINE (MUST
BE 10' FROM SEPTIC TANK
AND 25' FROM STA
% Co.
CP04,
���fGA lri
�1
100' TO WELL
Date: 08/25/2025
W2.0
Designed by: CBO Sheet 2 OF 4
Drawn by: DID
NOTE: TRENCHES MUST BE LEVEL BEGINNING
TO END
INFILTRATIVE AREA (BOTTOM OF TRENCH) AT
APPROX. 2' BELOW GRADE, NO DEEPER
INFILTRATOR GRAVELLESS'QUICK-4'
END PLATE CHAMBER (4' x 3')
L4" DIA SDR-35 INSPECTION PORT AT BEGINNING
AND END OF EACH TRENCH
4 CHAMBER TRENCH PLAN
-TO WALE
NOTE: DEPTH OF TRENCHES TO BE INSTALLED
AT APPROXIMATELY 2' BELOW GRADE.
RECOMMEND LOW PROFILE CHAMBERS.
2' max UNDi;
SOIL
4
LIMIT OF EXCAVATION
SCARIFY SURFACE
" DIA SDR-35 INSPECTION PORT
'I'min
J
DISTRIBUTION BOX WITH ACCESS AT GRADE
4" DIA SDR-35 EFFLUENT PIPE FROM SEPTIC
TANK
GRAVELLESS 'QUICK-4' CHAMBER (4' x T)
2 CHAMBER TRENCHSECTION
CBO Inc.
129 Cains Lane
Carbondale, Colorado 81623
Phone 970.309.5259
carla.ostberg@gmail.com
4" DIA SDR-35 DISTRIBUTION LINE TO EACH
TRENCH
(MIN. 1 % SLOPE TO TRENCH)
PIPES PLACED IN
TOP PORT OF CHAMBER END
PLATES
Spencer Charles Holdings LLC
Lot 33, Rapids on the Colorado
Garfield County, Colorado
Project Number: C1981
COMPACT SOII
BASE TO SUPPORT
BOX
USE HOLE SAW TO
CUT THRU TOP OF
END PLATTE
3 DISTRIBUTION BOX
NOW TO SdAIE
BOX AND COVER BROUGHT TO GRADE
CONCRETE LID
FINSHED GRP DE
SMALL VALVE COVER
BOX OR IRRIGATION
VALVE BOX AT GRADE
ATTACH CAP OR THREADED
CLEANOUT ASSEMBLY
4" PVC PIPE CUT TO
FIT
DISTRIBUTION BOX
SLIP-ON PVC CAP--::
DO NOT GLUE
INSULATED COPPER
TRACER WIRE FINISHED GRADE
4" DIA SDR-3
SEWER LINE
X
TO TANK TO HOUSE
6 CLEAN OUT DETAIL _E
BAFFLE OR
ANGLED PIPE
TO BE USED
AT INLET
Date: 08/25/2025
W3.0
Designed by: CBO Sheet 3 OF 4
Drawn by: DID
DESIGN
PROPOSED 4-BEDROOM RESIDENCE
75 GPD x 2 PERSONS/BEDROOM x 3 BEDROOMS + 75 GPD (4TH BEDROOM)
WASTEWATER FLOW = 525 GPD
USE MIN. 1250 GALLON, TWO -COMPARTMENT SEPTIC TANK
SOIL TREATMENT AREA (STA):
LONG TERM ACCEPTANCE RATE (LTAR) = 0.6 GAL/ SF
CALCULATED STA = Q/LTAR = 525 / 0.6 = 875 SF
875 SF x 1.0 (GRAVITY TRENCHES) x 0.7 (CHAMBERS) = 612.5 SF
612.5 SF / 12 SF/CHAMBER = MIN. 52 'QUICK 4' CHAMBERS
L PROFILE TEST PIT NO. 1
Ell
1 DARK BROWN TOPSOIL
2
SOIL PROFILE TEST PIT NO. 2
3
MEDIUM BROWN SANDY LOAM
w 4
w
w
5
a
w
6
SAND WITH INCREASING COBBLES
7 WITH DEPTH (R-0)
8
NO GROUNDWATER OR BEDROCK ENCOUNTERED
9 DURING EXCAVATION
10
3 SOILS LOG
(.-111 7 CBO Inc.
129 Cains Lane
':. Carbondale, Colorado 81623
Phone 970.309.5259
caria.ostberg@gmail.com
MEDIUM BROWN SANDY LOAM
MEDIUM BROWN SANDY LOAM
SAND WITH INCREASING COBBLES
WITH DEPTH (R-0)
LEGEND
Pq topsoil
7 sandy loam
OWTS COMPONENTS AND
PHYSICAL FEATURES
MINIMUM REQUIRED
SETBACK
APPROXIMATE PROPOSED
SETBACK
HOUSE TO SEPTIC TANK
5'
5'
SEPTIC TANK TO WELL
50'
N/A
SEPTIC TANK TO WATER COURSE
50'
N/A
STA TO HOUSE
20'
20'
STA TO WELL
100,
N/A
STA TO WATER COURSE
50'
N/A
Spencer Charles Holdings LLC
Lot 33, Rapids on the Colorado
Garfield County, Colorado
Project Number: C1981
2 SETBACK GHARHor To
FINISHED GRADE
�I BACKFILL I 24" MIN.
� I-
i
i
4" DIA SDR-35 SEWER LINE
(MIN 2% SLOPE TO TANK)
SCREENED ROCK
OR SAND FOR 3" MIN.
BEDDING
8" MIN.
2 TRENCH DETAIL
p 5'-'-LE
Date: 08/25/2025
W4.0
Designed by: CBO Sheet 4 of 4
Drawn by: DID
Edge of chip/seal
Rapids View
Lane Found 1-1/2" aluminum cap and
rebar set flush with grade, PLS
0 No. 13501 /
Improvement Location Certificate
Lot 33, The Rapids on the Colorado Subdivision
As Amended
Situated in the SW1/4 Section 4
Township 6 South, Range 91 West of the 6th P.M.
Telep one riser I 1 6 , 200' ISDS setback from County of Garfield, State of Colorado
11� 11-� �s3 ' /--- domestic well located County Parcel ID'No. 218104307033
Roadside % 'S' on Lot 30,
ditch � S nai a, �
1 I Curb stop
�P-et nai at "I
a� 20' and 10' Utility, Draina �I9
and Irrigation easements p r I�►
\ the Rapids on the CoioradjSubd�- ,� \
►�\ Outline of building setbacks
0 \� as per the final plat ck the �� • \
N st\ \ Rapids on the Colorado Subd. i
�� Domestic well Lot 30
�\ r Found 1-1/2" aluminum cap and
\ rebar set flush with grade, PLS
\ No. 13501
Set nail/lath \
�5 Lot 33 ti� o
\ Set nail/lath ThdRapids on the Colorado
' \ Sub6visian as Amended \ \
Found 1-1/2" aluminum cap a d \ \ (1kec. No. 639203) \ \ a` 0 rp
rebar set flush with grade, P \ \ \ (Vacant) \ \ o
No. 13501
\ \ (2.00 acres as platted) \
�\ \ Outline of building setbacks \
as per the final plat of the / \
\ \ \\ Rapids on the Colorado Subd. \
\ \.\ Set nail/lath J \
d dp\ 10' and 30' Utility, Drainage �- Set nail/lath--•
and Irrigation easements per i Found 1-1/2' aluminum
�the Rapids on the Colorado Subd. f cap and rebar set flush
\ with grade PLS No.
` 13501.
G
Ditch \' et ail/lath — - -—
\ Found 1- aluminum cap and
O��w r et flush with grade, PLS
S�uv } 2 No. 13501
Found 1-1/2" aluminum cap and �d9e of chi91 Q mad I e al descri tian:
rebar set flush with grade, PLS d? owa l 1` Lot 33
No. 13501 JOL The Rapids on the Colorado
Gar 1 according to the amended plat
thereof as filed for record
Oct. 24, 2003 under Reception No.
GRAPHIC SCALE 639203.
SurvCo, Inc. County of Garfield
Professional Land Surveying Services 6i 0 3` 60 State of Colorado
"Serving Western Colorado since 1991" Street address:
826-1 /2 Grand Avenue
Post Office Box 2782 ( IN FEET ) Not assigned
New Castle, CO. 81647
Glenwood Springs, CO. 81602-2782 1 inch = 60 ft (not within municipal limits)
ci irvrntMnm n iI nnm
Improvement Location Certificate:
(Certification pursuant to C.R.S. 38-51-108)
I hereby certify that this Improvement Location Certificate was prepared by
SurvCo, Inc., for Spencer Charles Holdings, LLC, that it is not a land survey
plat or improvement survey plat and that it is not to be relied upon for the
establishment of fence, building, or other future improvement lines.
This certificate is valid only for use by Spencer Charles Holdings, LLC, and
describes the parcels appearance on April 12, 2025.
I further certify that the improvements on the above described parcel on this
date, April 12, 2025, except utility connections, are entirely within the boundaries
of the parcel, except as shown, that there are no encroachments upon the described
premises, except as indicated, and that there is no apparent evidence or sign of
any easement crossing or burdening any part of said parcelI, a ept as noted.
By: Samuel D. Phelps
Colorado Licensed Professional
Land Surveyor No. 27613
For and on behalf of SurvCo, Inc.
A Colorado corporation
Date of certification: April 12, 2025
Surveyor's notes:
oa L0
�c �
44
'
amu'a D. Phelps
27613
1) This Improvement Location Certificate does not represent a title search by this
land surveyor or land surveying company. All information pertaining to ownership,
easements and other encumbrances of record is taken from a title insurance
commitment issued by Land Title Guarantee Company, title insurance commitment order
No. GB63021822-2, effective date March 21, 2025 at 5:00 P.M.
2) This property is subject to mineral right reservations and US patent rights as noted
in the above referenced title insurance commitment.
3) This property is subject to protective covenants and restrictions as noted in the above
referenced title insurance commitment.
4) This Improvement Location Certificate is based upon the monumentation found in the field
as indicated hereon and the record plat for the subject property (Reception No. 639203).
5) All linear dimensions shown hereon are in US survey feet.
6) Certain plat notes appear on the subdivision plat of The Rapids on the Colorado as Amended
that affect the subject property and by this reference are noted hereon.
Notice: Pursuant to C.R.S. 13-80-105 :
According to Colorado law you must commence any legal action based upon any defect in this
Improvement Location Certificate within three years after you first discover such defect.
In no event may any action based upon any defect in this Improvement Location Certificate be
commenced more than ten years from the date of certification shown hereon.
CURVE TABLE
Curve No.
Arc Length Radius Central Angle
Chord Bearing Chord Distance Tangent Distance
C1
53.21' 50,00' 60058'23"
N36037'25"E 50.73' 29.44'
�C2
114.08' 970.00' 6044'19"
N72051'11"E 114.02' 57.11'
��gRub11c.netT1 Garfield County, CO
Overview
Legend
Parcels
Roads
Parcel/Account
Numbers
Owner Name
Lakes & Rivers
County Boundary
Line
Account Number
R170385
Physical Address 0 Total Actual Value
$0 Last 2 Sales
Parcel Number
218104307033
NEW CASTLE 81647
Date Price
Acres
2
Owner Address SPENCER CHARLES HOLDINGS LLC
5/5/2025 $240,000
Land SgFt
0
200 MOUNTAIN SHADOW DIRVE
n/a $
Tax Area
017
GLENWOOD SPRINGS CO 81601
Mill Levy
58.1430
Date created: 8/6/2025
Last Data Uploaded: 8/6/2025 2:12:13 AM
Developed by ` S C H N E I D E R
GEOSPATIAL
8/6/25, 12:21 PM gPublic.net - Garfield County, CO - Property Record Card: R170385
Garfield County, CO
Summary
Account
R170385
Parcel
218104307033
Property
NEW CASTLE, CO 81647
Address
Legal
Section: 4 Township: 6 Range: 91 Subdivision: RAPIDS ON THE
Description
COLORADO Lot: 33
Acres
2
LandSgFt
0
Tax Area
17
Mill Levy
58.1430
Subdivision
RAPIDS ON THE COLORADO
View Map
Map
Owner
SPENCER CHARLES HOLDINGS LLC
200 MOUNTAIN SHADOW DIRVE
GLENWOOD SPRINGS CO 81601
Land
Unit Type 1 AC TO L/T 5 AC - 0520 (VACANT LAND)
Square Feet 0
Acres 2
Actual Values
Tax Year 2025 2024 2023 2022 2021
Actual Value $122,610.00 $144,200.00 $144,200.00 $38,720.00 $37,590.00
Assessed Values
Tax Year
Non School Assessed Value
School Assessed Value
Pre 2025 Assessed Value
2025 2024 2023 2022 2021
$33,100.00 n/a n/a n/a n/a
$33.100.00 n/a n/a n/a n/a
n/a $40,230.00 $40,230.00 $11,230.00 $10,900.00
`House Bill 2413-1001 established a separate assessment rate for school district residential properties, effective for the 2025 tax year and beyond. Click here for Assessor
FAQs
Mill Levies
Tax Year
2025 2024
2023 2022 2021
Non School District Levy
31.027
n/a
n/a
n/a
n/a
School District Levy
27.116
n/a
n/a
n/a
n/a
Total Levy
58.143
58.143
51.115
55.192
62.321
https:f/gpublic.schneidercorp.com/Application.aspx?ApplD=1038&Layerl D=22381&PageTypelD=4&PagelD=9447&Q=2071001544&KeyValue=R170385 1 /2
8/6/25, 12:21 PM
Tax History
Tax Year
Taxes Billed
gPublic.net - Garfield County, CO - Property Record Card: R170385
2024 2023
$2,339.08 $2,056.36
2022
$619.80
2021
$679.28
Clrc- here tov!ew the tax informa t ion for this carceton [lie Garheld County Tre 1surer's we bsi te.
Transfers
Sale Date Deed Type Reception Number
Book - Page
Sale Price
5/5/2025 SPECIAL WARRANTY DEED 1006602
$240,000
12/28/2001 SPECIAL WARRANTY DEED 594733
1316-983-987
$0
9/8/1997 SUBDIVISION IMPROVEMENTS
1032-0948
$0
9/3/1997 SPECIAL WARRANTY DEED
1032-0945
$0
1/1/1900 QUIT CLAIM DEED
513355
1032-0961
$0
1/1/1900 Resolution (various types)
499822
0996-0665
$0
1/1/1900 Resolution (various types)
435827
0834-0233
$0
1/1/1900 WARRANTY DEED
265351
0466-0207
$0
1/1/1900 WARRANTY DEED
265350
0466-0204
$0
1/1/1900 WARRANTY DEED
265246
0466-0029
$0
1/1/1900 Deeds
0479-0429
$0
Property Related Public Documents
Click here to view Property Related Public Doc umew
No data available for the following modules: Buildings, Photos, Sketches.
T',F �anaio �ouinws_ui __❑dI_c��v �._ fisp �ducc the rhos?a_c Jrc l-
Devcic')CCI 1'y
nfo pc,,s0c ',r C cscdo� �pk'cac _. C"'id'dio't a, - C:
SCHNEIDER
USE C� I—'C-1 cJl y!rt tC CO`!�ld"n "�=i'IEE a"[ r<< :,I'F�)'�ind C?"i:�" 'l
-
r aeosnnrinL
cannot uc e,ia-a, tc _c,
Laser Privacy PoriSy� GDPR_ Privacy N20ce
Last Data U2Ioad:.816/2025.12:12A.3AMA
https:17gpublic.schneidercorp.com/Application.aspx?ApplD=1038&LayerlD=22381&PageTypelD=4&PagelD=9447&Q=2071001544&KeyValue=R170385 2/2