Loading...
HomeMy WebLinkAboutBlower Door Report�= Retrotec rCloud Quality Assurance Report Single direction Multi Point Blower Door Test PASS '' Your Result: 2.68 ACH50 (1307." CFM50 60129268 ft3) Target < 3 ACH50 Test Information Test Name Test Date Export id Company Name Technician Name Technician Email Building Information Address City State Zip/postal Code Country Year Constructed Elevation Address Verified? Building Latitude, Longitude GPS validation Estimated Distance From Address Test Equipment Fan Model Fan Serial Number Pressure Gauge Model Gauge Serial Number Environmental Conditions Pre -test Indoor Temperature Pre -test Outdoor Temperature Wind Speed Average Barometric Pressure Test Dimensions Conditioned Floor Area Volume 481 Rapids View Lane 2025-10-17 09.48 AM (MDT) DKM9SG94 Dexter Diagnostics Amanda Poindexter dexterdiagnostics@gmail.com 91 E Double Hitch Eagle co 81631 United States 2025 6720 ft No Your location has not been validated. Tester location not verified Not available Retrotec 5000 5FN105365 Retrotec DM32X 502769 65 OF 31 OF 2 MPH 102.2 kPa 2545 ft2 29268 W �Xerrui' Test Notes No notes entered. Retrotec rCloud Flow Equation Parameters - Retrotec Calibrated Flow Parameters Fan Last Calibrated: 2024-09-11 Fan Model Retrotec 5000 Fan Serial Number 5FN105365 Fan Last Calibrated: 2024-09-11 Units Used For Flow Parameters in Equation CFM Fan pressure (FP) is the measured fan pressure when using a self -referenced fan or when the room pressure is negative. If using a fan which is not self -referenced, and the room pressure is positive, fan pressure is calculated by subtracting the measured room pressure from the absolute value of the fan pressure. If PrA is greater than 0 or fan is self -referencing: FP = jPrBj - PrA If PrA is less than 0 or fan is self -referencing: FP = PrB Flow calculations are not valid if fan pressure is less than either MF or (K2 x IRPj) FP = fan pressure, RP = room pressure Range N K K1 K2 K3 K4 MF Open 0.4990 555.2054 0.0000 0.3000 0.0000 1 10 A 0.5030 290.8751 0.0000 0.4000 0.0000 1 20 B8 0.5270 121.5413 0.0000 0.7000 0.0000 1 35 flow =(I-P-RPxK1)"x(K+K3xFP) xK4 Range A B C D B4 0.0000176573 -0.01530302 6.2742 138.42 B2 0.0000025309 -0.00466154 2.7545 25.71 B1 0.0000027369 -0.00313712 1.4891 10.71 1 B74 0.0000007960 -0.00095010 0.5900 18.00 i B47 0.0000002690 -0.00035905 0.2435 12.05 1 B29 0.0000001110 -0.00014900 0.0920 4.40 flow=(AxFP(G- RP) xF) F G K2 MF 0.59 50 0.8000 40 0.92 50 1.0000 50 0.45 50 1.0000 60 0.15 25 0.8000 35 0.09 25 1.0000 50 -0.02 25 0.6000 50 3