Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Blower Door Test
Testing Company: Name: Address: Technician: Name:Brian Chesney Credentials:BPI Certified ID#5068969 Email:c5energygj@gmail.com Building Information: Project ID:20 Roan Creek dr Address:20 Roan Creek Drive Battlement Mesa, Colorado 81635 Geo-Tag Data:Latitude: 39.457047 Longitude: -108.031401 Timestamp: 2025-10-20 11:59:59 Customer Information: Name: Address: Measured Leakage:2.66 ACH50 Leakage Target:3.00 ACH50 Compliance with Leakage Target:Pass Test ID:Blower door Purpose of Test:Envelope (IECC) Measured CFM50:1,264.1 Effective Leakage Area: 69.5 in² Building Volume:28,521.0 ft³Enclosure Surface Area: 0.0 ft² Coefficient (C):99.4 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 63 °F Altitude: 5,213.0 ft Outdoor Temp: 56 °F Time Average Period: 10 seconds Test Date and Time:2025-10-20 12:02:32 10% Adjustment Applied: No Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline 0.1 -50.0 -49.9 -49.9 -47.4 1,247.3 Ring A Test Equipment: Flow Device:Model 3 110V Fan Pressure Gauge:DG1000 Serial #: 13229 Calibration Date: 2024-08-27 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.10.2 (3), © 2025 The Energy Conservatory, Inc.