HomeMy WebLinkAboutManual J ReportLoad Short Form Job: 51 Boulder Ridge Dr ++ wrightsoftp Date: 7/25/25 Entire House By: Toby Monger Monarch HVAC Project Information For: Zane Balerio, Integrity Homes 1380 North Ave, Grand Jct, Co 81501 Phone: 970-255-6520 Email: zaneb@integrity.builders Design Information Htg Clg Infiltration Outside db (°F) -2 93 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 72 18 Fireplaces 1 (Average) Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/lb) 62 -45 HEATING EQUIPMENT Make Amana Trade AMANA Model AD9S960603BN AHRI ref 215224979 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 96.1 AFUE 60000 Btuh 58000 Btuh 60 °F 1078 cfm 0.035 cfm/Btuh 1.00 in H2O COOLING EQUIPMENT Make Amana Trade AMANA Cond ALXS3BN3010A Coil CAPTA3626B3A+AD9S960603BNA AHRI ref 215273729 Efficiency 11.2 EER2,13.8 SEER2 y Sensible cooling 19740 Btuh � Latent cooling 8460 Btuh Total cooling 28200 Btuh Z Actual air flow 1078 cfm Air flow factor 0.059 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) Crawler 2020 0 0 0 0 Bed 3 178 4322 1795 152 105 Entry 160 2397 1032 84 60 Bath 47 617 125 22 7 Bed 2 156 2060 1736 73 102 Mud 50 838 242 29 14 Pdr 37 688 99 24 6 H 61 0 0 0 0 Laun 88 0 0 0 0 Liv 317 5032 3251 177 190 Din 201 4560 3722 161 218 Kit 158 634 1253 22 73 P 33 0 0 0 0 9G WC 29 lull 265 36 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsaft' ��.$ ._ ... . _.. _. ..... Right-SuiteO Universal 2025 25.0.03 RSU65503 /ti+� k ...tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ8 Front Door faces: SE 2025-Oct-27 12:16:48 Page 1 RA rvr onus IOU ZUZU (it /1 4Z WIC 111 1013 545 36 32 M Bed 246 5425 3632 191 213 Entire House 4022 30623 18414 1078 1078 Other equip loads 5821 1431 Equip. @ 0.98 RSM 19389 Latent cooling 0 TOTALS 4022 36443 19389 1078 1078 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. + wrightsof - . Right -Suite® Universal 2025 25.0.03 RSU65503 ...tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ8 Front Door faces: SE 2025-Oct-27 12:16:48 Page 2 +�+ wrightsofte Component Constructions Entire House Monarch HVAC Job: 51 Boulder Ridge Dr Date: 7/25/25 By: Toby Monger Project For: Zane Balerio, Integrity Homes 1380 North Ave, Grand Jct, Co 81501 Phone: 970-255-6520 Email: zaneb@integrity. builders Design Conditions Location: Indoor: Heating Cooling Rifle Garfield County AP, CO, US Indoor temperature (°F) 70 75 Elevation: 5522 ft Design TD (°F) 72 18 Latitude: 40oN Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 62.4 -44.5 Dry bulb (T) -2 93 Infiltration: Daily range (TF) - 34 ( H ) Method Simplified Mt bulb(°F) - 58 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain tt' BtuhKt2-'F fF-°F/Bdih Bluh/R' Btuh Btuhlft' Btuh Walls 12C-5sw: Firm wall, stucco ext, 3/8" wood shth, r-13 cav ins, 1/2" gypsum board int fish, r-5 ext bd ins, 2"x4" wood frm, 16" o.c. stud 15B19-Owc-4: Bg wall, light dry soil, 2"x6" wood int frm, concrete wall, r-19 cav ins, 8" thk Partitions 12F-Osw: Frm wall, r-21 cav ins, 1/2" gypsum board int fish, 2"x4" wood frm, 16" o.c. stud ne 306 0.064 18.0 4.61 1411 071 219 se 148 0.064 18.0 4.61 683 0.71 106 sw 492 0.064 18.0 4.61 2268 0.71 351 w 32 0.064 18.0 4.61 147 0.71 23 nw 348 0.064 18.0 4.61 1604 0.71 248 all 1327 0.064 18.0 4.61 6113 0.71 947 ne 194 0.047 19.0 0 0 0 0 se 155 0.047 19.0 0 0 0 0 sw 187 0.047 19.0 0 0 0 0 w 10 0.047 19.0 0 0 0 0 nw 148 0.047 19.0 0 0 0 0 all 694 0.047 19.0 0 0 0 0 474 0.065 21.0 4.68 2216 0.24 115 Windows 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk: ne 47 0.300 0 21.6 1015 24.0 1127 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8" thk; se 48 0.300 0 21.6 1037 28.9 1385 6.67 ft head ht sw 72 0.300 0 21.6 1555 28.9 2078 nw 126 0.300 0 21.6 2722 24.0 3022 all 293 0.300 0 21.6 6329 26.0 7613 Doors Door, wd sc type: Door, mtl fbrgl type Ceilings 1613-38ad: Attic ceiling, asphalt shingles roof mat, r-38 cell ins, 1/2" gypsum board int fish se 21 0.300 6.3 21.6 454 6.70 141 sw 21 0.300 6.3 21.6 454 6.70 141 n 21 0.300 6.3 21.6 454 6.70 141 all 63 0.300 6.3 21.6 1361 6.70 422 2002 0.026 38.0 1.87 3749 1.19 2387 1 wrighTsnft 2025-Oct-2712:16:48 Right -Suite® Universal 2025 25.0.03 RSU65503 Page 1 tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ8 Front Door faces: SE Floors 19D-Ocstp: Fir floor, frm fir, 12" thkns, tight crwl ovr, r-19 wall insul 2002 0.368 19.0 1.25 2507 0.31 616 22A-tpl: Bg floor, light dry soil, on grade depth ti wrighLsnft Right -Suite® Universal 2025 25.0.03 RSU65503 ...tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ8 Front Door faces: SE 231 0.989 2025-Oct-27 12:16:48 Page 2 Project Summary Job: 51 Boulder Ridge Dr rai ry wrightsofte Date: 7125/25 (Entire House By: Toby Monger Monarch HVAC Pro'ect Information For: Zane Balerio, Integrity Homes 1380 North Ave, Grand Jct, Co 81501 Phone: 970-255-6520 Email: zaneb@integrity. builders Notes: ,Design Information Weather: Winter Design Conditions Outside db Inside db Design TD Ventilation Method -2 °F 70 °F 72 °F ASHRAE 62.2-2019 Heating Summary Structure 30011 Btuh Ducts (R-8.0) 611 Btuh Central vent (90 cfm) 5821 Btuh Outside air, FV-0511VKS2 Humidification 0 Btuh Piping 0 Btuh Equipment load 36443 Btuh Infiltration Method Construction quality Fireplaces Rifle Garfield County AP, CO, US Simplified Average 1 (Average) Heating Cooling Area (ft2) 2002 2002 Volume (fP) 18700 18700 Air changes/hour 0.38 0.16 Equiv. AVF (cfm) 120 50 Heating Equipment Summary Make Amana Trade AMANA Model AD9S960603BN AHRI ref 215224979 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 96.1 AFUE 60000 Btuh 58000 Btuh 60 °F 1078 cfm 0.035 cfm/Btuh 1.00 in H2O Summer Design Conditions Outside db 93 °F Inside db 75 °F Design TD 18 °F Daily range H Relative humidity 50 % Moisture difference -45 gr/lb Sensible Cooling Equipment Load Sizing Structure 17886 Btuh Ducts (R-8.0) 528 Btuh Central vent (90 cfm) 1431 Btuh Outside air, FV-0511VKS2 Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Equipment sensible load 19389 Btuh Latent Cooling Equipment Load Sizing Structure -432 Btuh Ducts -97 Btuh Central vent (90 cfm) -2226 Btuh Outside air, FV-0511VKS2 Equipment latent load 0 Btuh Equipment Total Load (Sen+Lat) 19389 Btuh Req. total capacity at 0.81 SHR 2.0 ton Cooling Equipment Summary Make Amana Trade AMANA Cond ALXS3BN3010A Coil CAPTA3626B3A+AD9S960603BNA AHRI ref 215273729 Efficiency 11.2 EER2,13.8 SEER2 Sensible cooling 19740 Btuh Latent cooling 8460 Btuh Total cooling 28200 Btuh Actual air flow 1078 cfm Air flow factor 0.059 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 1.00 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigtiteoft' 2025-Oct-2712:16:48 -- - -- Right -Suite® Universal 2025 25 0.03 RSU65503 Page 1 �� ...tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ6 Front Door faces: SE r ENERGY STAR Single -Family f National HVAC Design Report, New Homes Version 3.1 /3.2 /3.3 (Rev. 14) HVAC Designer Responsibilities: • Complete one National HVAC Design Report for each system design for a house plan, created for either the specific plan configuration (i.e., elevation, option, orientation, & county) of the home to be certified or for a plan that is intended to be built with different configurations (i.e., different elevations, options, and/or orientations). Visit www.energystar.gov/newhomeshvacdesign and see Footnote 2 for more information. • Obtain efficiency features (e.g., w indow performance, insulation levels, and infiltration rate) from the builder or Rater. 3 • Provide the com leled National HVAC Design Report to the budder or credentialed HVAC contractor and to the Rater. i 1.1 Designer name: Toby Monger Designer company: Monarch HVAC Date: 7/25/25 1.2 Select which party you are providing these design services to: ti Builder or 0 Credentialed HVAC contractor 1.3 Name of company you are providing these design services to (if different than Item 1.1): Integrity Homes 1.4 Area that system serves: A Whole -house 0 Upper -level 0 Lower -level 0 Other 1.5 Is cooling system for a temporary occupant load? 0 Yes M No 1.6 House plan: Check box to indicate whether the system design is site -specific or part of a group: M Site -specific design. Options) & elevation(s) modeled: 51 Boulder Ridge Dr © Gro up design . G ro up #: 0 out of 0 total Q rou ps for this house Wan. Configuration modeled: Designer 2. Dwellina Unit MechaniGall Ventilation System i n "VReturn Duct Verified Airflow: 2.1 Ventilation airflow design rate & run-time meet the requirements of ASHRAE 62.2-2010 or later 2.2 Ventilation airflow rate required by 62.2 for a continuous system: 90 CFM - 2.3 Design for this system: Vent. airflow rate: 90 CFM Run-time per cycle: 0 minutes Cycle time: 0 minutes Sy stem Type & Controls: 2.4 S ecified s stem e: 0 Supply M Exhaust 0 Balanced 2.5 Specified control location: Crawler (e.., Master bath, utility room) 2.6 Specified controls allow the system tooperate automatically, without occupant intervention. 0 2.7 Specified controls include a readily -accessible ventilation override and a label has also been specified if its function is not obvious (e.g.. a label is required for a toggle w all sw itch, but not for a sw itch that's on the ventilation equipment). 2.8 For any outdoor air inlet designed to connect to a ducted return of the HVAC system, specified controls automatically restrict airflow using a motorized damper durin2 ventilation off-e cle and occupant override. 0 Sound: 12.9 The fan of the specified system is rated 5 3 sones if intermittent and 5 1 Bone if continuous, or exempted Efficiency: 2.10 If Vent System controller operates the HVAC fan, then HVAC fan operation is intermittent and either the fan type in Item 4.7 is ECM / ICM or the controls will reduce the run-time by accounting for HVAC system heating or cooling hours. 0 2.11 If bathroom fans are specified as part of the system. then they are ENERGY STAR certified 0 Air Inlet Location: (Complete this section if system has a specified air inlet location; otherw Ise check "WA") Ittti N/A 2.12 Inlet pulls ventilation air directly from outdoors and not from attic, crawls ace, garage, or adjacent dwelling unit 0 2.13 Inlet is z 2 ft. above grade or roof deck; Z 10 ft. of stretched -string distance from know n contamination sources (e.g., stack, vent, exhaust, vehicles) not extting the roof, and z 3 ft. from know n sources exiting the roof o 3. Room -by -Room Heating & Cooling Loads _3_11_RW02-�v-room loads olcul7 M Umbdoged ACCA Manual J Y.8 0 2013 ASHRAEF m m n I 0 h r 1perAH Indoor in loads are7O'F for heating n r coolingttti 3.3 Outdoor design temperatures used in loads: (See Footnote 18 and www.energystar.gov/hvacdesigntemps) County & State, or US Territory, selected: Garfield, CO Cooling season: 93 -F Heating season: -Z °F 3.4 Number of occupants used in loads: 4 3.5 Conditioned floor area used in loads: 2002 Sq. Ft. 3.6 Window area used in loads: 293 S . Ft. 3.7 Predominant window SHGC used in loads: 0.30 3.8 Infiltration rate used in loads: Summer: 0.16 Winter: 0.38 3.9 Mechanical ventilation rate used in loads: 90 CFM Loads At Design Conditions kBtuh N NE E SE S SW W NW 3.10 Sensible heat gain (By orientation) 19.4 Cooling 3.11 Latent heat gain (Not by orientation) 10 _ 3.12 Total heat gain (By orientation 19.4 _ 3.13 Maximum -minimum total heat gain (Rem3.12) across orientations = 0 kBtuh Variation is 5 6 kBtuh ttt# Heating 3.14 Total heat loss (Not by orientation) 36.4 Bold/italic values have been manually overridden 41- wricp"tsvft 2025-Oct-27 12:16:48 """' Right-Suite®Universal202525.0.03 RSU65503 Page tsoft\51 Boulder Ridge Dr (Battlement Mesa).rup Calc = MJ8 Front Door faces: SE }; J ENERGY STAR Single -Family New Homes National HVAC Design Report, Version 3.1 /3.2 /3.3 (Rev. 14) Designer in C ling I Verified 4.1 Equipment selected per ACCA Manual S see Footnote 26 & 27). 0 Air C n i i n r/ H if air conditioner or heat numn will initalledm pthenNise check"N/A7) 0 N/A 4.2 Equipment type: M Cooling -only air conditioner or 0 Cooling & heating heat pump 4.3 Condenser manufacturer & model: Amana ALX 3BN3010A 4.4 Evaporator / fan coil manufacturer & model: Amana CAPTA3626B3A+AD9S960603BNA 4.5 AHRI reference *: 215273729 4.6 Rated cooling efficiency: 11.2 EER2/13.8 SEER2 Rated heating efficiency: 4.7 Evaporator fan type: 111111111 PSC 0 ECM / ICM 0 Other: 4.8 Compressor type: M Single -speed 0 Two -speed 0 Variable -speed 4.9 Latent capacity at design conditions, from OEM expanded performance data: 1.1 kBtuh - 4.10 Sensible capacity at design conditions, from OEM expanded performance data: 26.6 kBtuh - 4.11 Total capacity at desi n conditions, from OEM expanded performance data: 27.7 kBtuh - 4.12 Air -source heat pump Capacity: At 17°F: 0 kBtuh At 47"F: 0 kBtuh R N/A 4.13 Cooling sizing % = Total capacity (Item 4.11) divided by maximum total heat gain (Item 3.12): 143 4.14 Complete this Rem if Condition B Climate w ill be used to select s izing limit in Item 4.15. Otherw ise, check "WA": 0 N/A 4.14.1 Load sensible heat ratio = Max. sensible heat gain Item 3.10) / Max. total heat 2ain Item 3.12 = 100% 4.14.2 HDD / CDD ratio (Visit www.energystar.gov/hvacdesigntemps to determine this value for the design location )= 4-2 4.15 Check box of applicable cooling sizing limit from chart below: Equipment Type (Per Item 4.2) & Climate Condition (Per Item 4.14) Compressor Type Per Item 4.8 Single -Speed Two -Speed Variable -Speed For Cooling -Only Equipment or For Cooling Mode of Heat Pump in Condition A Climate Recommended: 90 -115% p Allowed: 90 -130% Recommended: 90 -120% 0 Allowed: 90 -140% Recommended: 90 -130% 0 Allowed: 90 -160% For Cooling Mode of Heat Pump in Condition B Climate 0 90% - 100%, plus 15 kBtuh 0 90% - 100%, plus 15 kBtuh 0 90% - 100%, plus 15 kBtuh 4.16 Cooling sizing % 4.13) is within cooling sizing limit (4.15) 0 check "NIA') 0 N/A 4.17 Furnace manufacturer & model: Amana AD9 9606036N 4.18 Rated heating efficiency: 96.1 AFUE 4.19 Total capacity: 58 kBtuh 4.20 Heating sizing % = Total capacity (Item 4.19) divided by total heat loss item 3.14): 159% 4.21 Check box of applicable heating sizing limit from chart below: When Used for Heating Only When Paired With Cooling 0 100 - 140% M Recommended: 100 -140% Allowed: 100 -400% 4.22 Heating sizing % 4.20) is within heating sizing limit 4.21 5. D if heabno or coolina ea uipm ent will be il3stalled with ducts l otherwiseh 0 N/A 5.1 Duct system designed for the equipment selected in Section 4, per ACCA Manual D 5.2 Design HVAC fan airflow: Cooling mode 1078 CFM Heating mode 1078 CFM 5.3 Design HVAC fan speed setting (e.g., low, medium, high): Cooling mode High Heating mode Med-High 5.4 Design total external static pressure (corresponding to the mode with the higher airflow in Item 5.2): 1 IWC 5.5 Room -by -room design airflows documented below which must sum to the mode with the higher airflow in Item 5.2)- Room Name Design Airflow F Room Name Design Airflow F Room Name Design Airflow 1 Bath 7 12 M Bed 213 23 2 Bed 2 102 13 Mud 14 24 3 Bed 3 105 14 P 0 25 4 Crawler 0 15 Pdr 6 26 5 Din 218 16 WC 16 27 6 Entry 60 17 WIC 32 28 7 H 0 18 29 8 Kit 73 19 30 Laun 0 20 31 ht Liv 1 0 21 32 at 4 22 Total for all rooms 07 f}t- wrightsaft 2025-Oct-2712:16:48 Right -Suite® Universal 2025 25.0.03 RSU65503 Paget .tsoft\51 Boulder Ridge Dr (Battlement Mesa) rup Cale = MJ8 Front Door faces: SE Main Level Job #: 51 Boulder Ridge Dr Scale: 1 : 100 Performed by Toby Monger for: Monarch HVAC Zane Balerio Page 1 1380 North Ave Right -Suite® Univers al 202 5 Grand Jct, Co 81501 25.0.03 RSU65503 Phone: 970-255-6520 2025-Oct-27 12:17:52 zaneb@integrity builders r Ridge Dr (Battlement Mesa).rup IV Cond Crawler Job #: 51 Boulder Ridge Dr Monarch HVAC Scale: 1 : 100 Performed by Toby Monger for: Page 2 Zane Balerio Poght-SuiteO Universa12025 1380 North Ave 25.0.03 RSU65503 Grand Jct, Co 81501 Phone: 970-255-6520 2025-Oct-27 12:17:52 zaneb@integrity builders ...r Ridge Dr (Battlement Mesa).rup